background image

1-1202-US

Gear Pump Units

For single-line centralized lubrication systems

These units comprising the MFE Group are 
designed to supply the lubricant used in in-
termittently operated, single-line centralized 
lubrication systems. 

The basic setup includes a gear pump unit 
with motor, a 3- or 6-liter lubricant reservoir 
– optionally of metal or plastic – or a 15-liter 
metal reservoir and float switch to monitor 
the minimum permissible level of lubricant.

In addition to the basic models it is also 
possible for the units to be outfitted with 
add-ons. 

Special models for a wide variety of applica-
tions are listed in the overview table on 
page 3.

MFE5-KW3-2

MFE5-KW6

MFE5-BW7

Summary of Contents for MFE5-BW7

Page 1: ...sic setup includes a gear pump unit with motor a 3 or 6 liter lubricant reservoir optionally of metal or plastic or a 15 liter metal reservoir and float switch to monitor the minimum permissible level...

Page 2: ...h _Xbc SXbcaXQdc a PbbT Q h TPbdaX V cTa X P Pg _aTbbdaT bfXcRW Va d_ 3B F X _aTbbdaT bfXcRW Va d_ 3B F S bPVTb X RR Example of a single line central lubrication system for automobile makers The syste...

Page 3: ...2 2 float switch MFE5 KW6 S1 6 Plastic Basic version with WS35 2 float switch MFE5 KW6 S8 6 Plastic FKM FPM version WS32 S8 float switch MFE5 KW6 S24 6 Plastic VW version MFE5 KW6 S33 6 Plastic Motor...

Page 4: ...pump unit for flange mounting on oil reservoir Order No MFE5 Please quote voltage and frequency when ordering A special sealed pump must be used for horizontal flange mounting of the unit in a positio...

Page 5: ...oses off external port R1 Flanged port R2 of the return duct drains directly into the reservoir without any connection threads see Fig 3 and 4 Technical data of the shown motor Motor Three phase motor...

Page 6: ...types of motors in stock Range I 130 130 V 173 225 V 50 Hz 120 156 V 208 270 V 60 Hz order code 199 order code ISO F 19E Range III 230 290 V 398 500 V 50 Hz 290 346 V 500 600 V 60 Hz order code 399 o...

Page 7: ...rial without Order No l min l float switch MFE5 BW3 2 0 5 3 die cast aluminum MFE5 B3 2 MFE5 BW7 0 5 6 sheet steel MFE5 B7 Technical data Float switch WS for monitoring of minimum oil level Type of co...

Page 8: ...tube connection for 8 mm diam tube 2 Connection f cable 7 to 9 mm diam 3 Connection f cable 4 to 11 mm diam 1 Port tapped for solderless tube connection for 8 mm diam tube 2 Connection f cable 7 to 9...

Page 9: ...nge over contacts reed contacts Max switching voltage 230 V AC 230 V DC Max switching current 0 8 A Max switching capacityn 60 VA 40 W 3 Type of enclosure IP 65 Temperature range 10 C to 60 C 3 Take a...

Page 10: ...Gear pump units for single line centralized lubrication systems 10 1 1202 US Notes...

Page 11: ......

Page 12: ...your attention to the fact that hazardous materials of any kind especially the materials classified as hazardous by EC Directive 67 548 EEC Article 2 Par 2 may only be filled into VOGEL centralized lu...