Versions of the VOGEL Universal Control Unit

for industrial installations

Designation

Brief description

Model E+471

Housing for installation in switchgear cubicle,

selectable operating voltage 

100 .. 120 V AC or 200 .. 240 V AC

Model I+471

Housing installed in compact unit,

selectable operating voltage 

100 .. 120 V AC or 200 .. 240 V AC

Model E+472

Housing for installation in switchgear cubicle,

operating voltage 20 .. 24 V AC or DC

Model I+472

Housing installed in compact unit,

operating voltage 20 .. 24 V AC or DC

Our control units conform to the generally applicable standards.

Leaflet overview

Control units for progressive systems

117002US

Control units for oil+air lubrication

117003US

Control units for singleline systems

117004US

Universal Control Unit

www.vogelag.com

for Centralized Lubrication Systems
Functions and Operation of the Universal Control Unit

Control and Monitoring Units

117001US

Introduction

The product described in these instructions is a control and

monitoring unit for VOGEL central lubrication systems on station

ary industrial installations. It is supplied either as a constituent

part of VOGEL's compact lubrication units or individually for

installation in a switchgear cubicle.

The Universal Control Unit is the foundation of all our new con

trol and monitoring units, and it can also replace all the

switchgear cubicle units in use to date. Since the control func

tions can differ considerably, depending on the installation and

application, various models based on the Universal Control Unit

are available with functions corresponding to those of the control

units employed to date. The former designations for the individ

ual models have, for the most part, been retained.

The VOGEL Universal Control Unit for industrial lubrication 

systems is built to conform to the generally recognized state of

the art, and it complies with the applicable industrialsafety and

accidentprevention regulations.

Summary of Contents for E+471

Page 1: ...ol and Monitoring Units 1 1700 1 US Introduction The product described in these instructions is a control and monitoring unit for VOGEL central lubrication systems on station ary industrial installations It is supplied either as a constituent part of VOGEL s compact lubrication units or individually for installation in a switchgear cubicle The Universal Control Unit is the foundation of all our ne...

Page 2: ...ulse monitoring voltage unit E XZT2A02 E XZT2A02 E Single line systems voltage E XZT2A02 I Piston distributors E XZT2A03 E XZT2A03 E Single line systems voltage E XZT2A03 I Piston distributors E XZT2A05 E XZT2A05 E Progressive systems voltage E XZT2A05 I E XZT2A06 E XZT2A06 E Progressive systems voltage E XZT2A06 I E XZT2A07 E XZT2A07 E Single line systems voltage E XZT2A07 I Piston distributors I...

Page 3: ...trol unit has a separate power supply that has been installed by trained staff for parameterization purposes and all the other exposed parts are dead Structure of the operator displays The illustration shows the operator interface with its display and control elements The display elements are the 8 place LC dis play 1 and the LED displays 2 The pushbuttons 3 are the control elements The table prov...

Page 4: ...in energized position Changeover contact in de engergized position The info display The type of unit and firmware version of the controller can like wise be shown via the LC display The info display is changed to from the status display by press ing the button If the designation is more than eight places long the rest is shown by pressing the button in the display once again The info display mode ...

Page 5: ...ffect after the unit has been switched off and then started again Beforehand the entire display flashes after the mode is changed But the normal sequence of functions is still assured Parameter display possibilities LC dispaly Parameter designation Value range Unit BA Mode of operation A B C D E TP Interval time 01 E 00 99 E 04 M inutes S econds I mpulses TU Monitoring time 01 E 00 99 E 03 S econd...

Page 6: ...ut whether the unit is function ing Faults Fault displays If a fault detected by one of the monitoring sensors should occur while the central lubrication system is in operation the control unit will display the fault The red fault LED will light up and the symbol for the respective input will flash on the display Which fault is involved will depend on your type of unit You will find further inform...

Page 7: ...incidence factor for the inputs max 0 8 Version 471 and 472 Output voltage for inputs and external loads 24VDC 10 15 Rated output current outputs 110mA of that figure for external loads max 60mA MK input max input frequency 30Hz Pulse duty factor 1 1 Conductor connection flexible with tubular end sleeves max 2 5 mm2 or 2x0 75 mm2 with twin tubular end sleeves max 2x1 5 mm2 stripped length 8 mm Typ...

Page 8: ...g instructions are supplied together with the products the provi sions and information therein of specific relevance to the equipment must be observed as well In particular we call your attention to the fact that hazardous materials of any kind especially the materials classified as hazardous by EC Directive 67 548 EEC Article 2 Par 2 may only be filled into VOGEL centralized lubrication systems a...

Reviews: