TECHNICAL SPECIFICATIONS

Suitable for All Pressures

Minimum Pressure = 35kPa
Maximum operating Pressure = 500kPa* (As per NZ Building Code AS/NZ 3500.1)
Maximum operating Temperature = 65 deg. Celsius

For domestic use only.

CONFIGURATION

Mains Pressure systems  Prior to installation, remove the valve inserts from both inlets.
Unequal Low systems  Install as supplied. 
    

 

Important note: Only slide showers that are equipped with a large internal bore hose and open flow single 

 

 

 

 

function handset will work effectively with this shower mixer.    If the cold pressure difference is greater than    

 

 

 

 

10/1 ratio (i.e. 400kPa cold and 35kPa hot), we recommend installing the needle valve (supplied) preferably    

 

 

 

 

directly to the cold water feed port on the shower mixer or alternatively anywhere on the cold feedline pipe.

Equal Low systems 

Prior to installation, remove the valve inserts from both inlets.

INSTALLATION

*FOR PRESSURES EXCEEDING 500kPa INSTALL A PRESSURE REDUCING VALVE.  THOROUGHLY FLUSH ALL 
PIPES TO ELIMINATE ANY REMAINING DIRT AND RESIDUE,  AND INSTALL INLINE FILTERS. FAILURE TO DO 
SO MAY VOID THE WARRANTY.

   

Installation must comply with Section 5.4 of AS/NZS 3500 Standard with regard to Isolating stop cock use. Shower 
mixers must be water tested with the outlet open, to prevent damage to cartridge seals due to back pressure.

All pipe work must be flushed prior to the installation of this mixer, accessible inline filters must be installed in the 
pipework for both the hot and cold inlet supply to prevent particles from damaging the ceramic cartridge.  

Back Flow Prevention: Where back flow prevention is required, install our Back Flow Prevention Valve at the supply 
elbow hose connection of the handpiece.