![Voda STORM VST32 Quick Start Manual Download Page 1](http://html1.mh-extra.com/html/voda/storm-vst32/storm-vst32_quick-start-manual_1043734001.webp)
STORM
Shower Mixer
VST32
Voda Plumbingware Limited | Freephone: 0508 367 366 | 5 Hewlett Street, Port Whangarei 0110 | vodaplumbingware.co.nz
Congratulations on your purchase of this high quality product from Voda Plumbingware.
Please read the following before installation and retain (along with your receipt) for future reference.
TECHNICAL SPECIFICATIONS
Suitable for All Pressures
Minimum Pressure = 35kPa
Maximum operating Pressure = 500kPa* (As per NZ Building Code AS/NZ 3500.1)
Maximum operating Temperature = 65 deg. Celsius
For domestic use only.
CONFIGURATION
Mains Pressure systems Prior to installation, remove the valve inserts from both inlets.
Unequal Low systems Install as supplied.
Important note: Only slide showers that are equipped with a large internal bore hose and open flow single
function handset will work effectively with this shower mixer. If the cold pressure difference is greater than
10/1 ratio (i.e. 400kPa cold and 35kPa hot), we recommend installing the needle valve (supplied) preferably
directly to the cold water feed port on the shower mixer or alternatively anywhere on the cold feedline pipe.
Equal Low systems
Prior to installation, remove the valve inserts from both inlets.
INSTALLATION
*FOR PRESSURES EXCEEDING 500kPa INSTALL A PRESSURE REDUCING VALVE. THOROUGHLY FLUSH ALL
PIPES TO ELIMINATE ANY REMAINING DIRT AND RESIDUE, AND INSTALL INLINE FILTERS. FAILURE TO DO
SO MAY VOID THE WARRANTY.
Installation must comply with Section 5.4 of AS/NZS 3500 Standard with regard to Isolating stop cock use. Shower
mixers must be water tested with the outlet open, to prevent damage to cartridge seals due to back pressure.
All pipe work must be flushed prior to the installation of this mixer, accessible inline filters must be installed in the
pipework for both the hot and cold inlet supply to prevent particles from damaging the ceramic cartridge.
Back Flow Prevention: Where back flow prevention is required, install our Back Flow Prevention Valve at the supply
elbow hose connection of the handpiece.