63
Scavenge Tube
A 1/4 in PTFE tube (shown in orange) connects the WHASP Tank to the
compressor inlet valve. Vacuum from the compressor pulls the separated oil
from the coalescing filter, recirculating the oil in the system (Figure 48).
Figure 48
– Scavenge tube
(Key switch module removed for clarity)
Pressure Control Tubes
A 1/4 in PTFE tube (shown in green) connects the discharge valve to the
lower fitting on the side of the compressor inlet valve. This provides the
system air pressure (factory setting 150 psi) to operate the inlet poppet valve
(Figure 49).
Figure 49
– 1/4 in Pressure control tube
(Key switch module removed for clarity)
1/4 in compressor
fitting and air
bleed muffler
Discharge valve
1/4 in PTFE pressure
control tube
1/4 in WHASP Tank
scavenge fitting
(with one-way check
valve)
1/4 in PTFE
scavenge tube
1/4 in compressor
scavenge fitting