Air pressure relief valve 
failure. 

Check valve. 

Air Inlet solenoid valve 
failed in the ON state. 

Check solenoid and wiring.

 

 

Temperature Sensor Trouble Shooting

 

 

Temporarily override the compressor temperature sensor: 

 

This is only intended for use in an emergency to complete a job when servicing the unit 
is not immediately possible. Running without a temperature sensor may result in failure 
of the unit and/or damage to the hydraulic system, and is not recommended.

 

 

To temporarily disable the compressor temperature sensor, access the DIAGNOSTICS mode by 
pressing and holding the OFF button. Once in DIAGNOSTIC mode allow system to scroll through 
headings until the display shows: AIR TEMP SENSOR Press the ON button to access this 
setting.  

o

 

Press and hold the ON button until NO AIR TEMP PROBE DIS? Appears on the screen 
and then release the ON button.  

o

 

Press and hold the ON button again until TEMP PROBE DIS appears on the screen and 
then RELEASE the ON button.   

 

After the probe is disabled you need to back out of the DIAGNOSTIC screen by pressing both the 
ON and OFF buttons simultaneously. You will need to do this twice to back right out to the main 
screen. 

 

 

To reset the PREDATAIR to default settings turn the power OFF then ON again. This will reset 
the PREDATIAR temperature probes to ON. 

 

Temporarily override the hydraulic temperature sensor: 

 

This is only intended for use in an emergency to complete a job when servicing the unit 
is not immediately possible. Running without a temperature sensor may result in failure 
of the unit and/or damage to the hydraulic system, and is not recommended.

 

 

To temporarily disable the hydraulic temperature sensor, access the DIAGNOSTICS by pressing 
and holding the OFF button. Once in DIAGNOSTIC mode and allow system to scroll through 
headings until the display shows: HYD TEMP SENSOR? Press the ON button to access this 
setting. 

o

 

Press and hold the ON button until NO HYD TEMP PRB? Appears on the screen and 
then release the ON button. 

o

 

Press and hold the ON button again until TEMP PROBE DIS appears on the screen and 
then RELEASE the ON button.   

 

After the probe is disabled you need to back out of the DIAGNOSTIC screen by pressing both the 
ON and OFF buttons simultaneously. You will need to do this twice to back right out to the main 
screen. 

 

 

To reset the PREDATAIR to default settings turn the power OFF then ON again. This will reset 
the PREDATIAR temperature probes to ON. 

 

A video showing how to 

disable the PREDATAIR Temperature Sensors

 can be found here: 

https://www.youtube.com/watch?v=9jzzm0oTMgw

  

 

 

Summary of Contents for AIR INNOVATED H400001

Page 1: ...oting 7 Temporarily override the compressor temperature sensor 7 Temporarily override the hydraulic temperature sensor 7 Electrical Schematic 8 Overview General error codes symptoms and trouble shooti...

Page 2: ...______________________ Company _______________________ Email Fax ____________________ Date ________________ Error Code Error 1 Compressor has Over Temped 138C 2 Hydraulic has Over Temped 88C 3 Not Use...

Page 3: ...On Steady Off Operating None Off On Steady Compressor Off Fan On Compressor Too Hot Off Flashes On Off continuously Compressor Off Fan On Hydraulic Oil Too Hot One Flash Pause One Flash continuously...

Page 4: ...rting the PTO system The Cold Climate Kit A700146 can be installed to speed warm up once the hydraulic oil temperature has reached 13oF 25oC HYD OIL WARMING HYD XXXF XXXC The hydraulic oil is between...

Page 5: ...correct amount of hydraulic flow for the desired CFM Ensure that engine rpm is being maintained when load is applied Unload Solenoid Failure Check solenoid and wiring General Message Problem Possible...

Page 6: ...r or bad wiring connection Check the pressure sensor and wiring connections CONNECTION ERR Failed control box display box or bad wiring connection Failed control box display box or bad wiring connecti...

Page 7: ...probe is disabled you need to back out of the DIAGNOSTIC screen by pressing both the ON and OFF buttons simultaneously You will need to do this twice to back right out to the main screen To reset the...

Page 8: ...d by Tech Engineering Implemented EXT PRED 016 A Tech Document Release SP 18 Aug 2015 DB 18 Aug 2015 N A 18 Aug 2015 Page 8 of 8 Knowledge Base www kb vmacair com Email tech vmacair com Web www vmacai...

Reviews: