21
http://ioxec/protect/set.cgi?out0=0
To toggle output 3:
http://ioxec/protect/set.cgi?out0=t
To turn on the internal buzzer:
http://ioxec/protect/set.cgi?out8=1
6.7.2
Analog output
To change the analogue value of the analog output, issue the following HTTP (GET) request:
http://<address>/protect/set.cgi?aout=val
Where val is the desired voltage of the output.
Example:
To set the output voltage to 2.55Volt
http://ioxec/protect/set.cgi?aout=2.55
6.8
Reboot IO.XEC
To reboot IO.XEC use the following HTTP (GET) request:
http://<address>/protect/reboot.cgi
7
Firmware update
The IO.XEC firmware is updateble. With this feature, IO.XEC can run the most up to date
firmware revision.
This operation is very simple and is supposed to be done by the user or installer. You need an
USB flash drive in order to proceed.
The steps needed to make a firmware update are the following:
1.
Download the firmware image. A file named
image.bin
2.
Copy the file to the root directory (folder) of the USB flash drive
3.
Turn off IO.XEC
Summary of Contents for IO.XEC