ES018 VIVOG PROFESSIONAL STERILISER 

Instructions for use, maintenance, and safety guidelines 

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE TURNING ON THE STERILISER FOR THE FIRST TIME 

Specifically developed for sterilising grooming instruments, the 
Vivog  ES018  represents  the  latest  generation  of  UV  light 
sterilisers.  The  steriliser  sterilises  grooming  instruments  to 
99.9%.

 

It is composed of a high quality body in plastic injected and of 
an  interior  aluminium  box  with  high  thermal  efficiency  thus 
improving  the  output  of  thermo-electric  resistance  and  the 
reflexion-refraction of the ultraviolet ray lamp. 

Important: please follow the guidelines for use 

SAFETY PRECAUTIONS 

- Make sure that the steriliser is placed on a strong, solid, flat surface.
- The power cable of the steriliser should be unplugged from the wall
socket whenever the machine is not in use.
- Check  that  the  voltage  indicated  on  the  plate  corresponds  to  your
electrical  supply.  Your  electrical  supply  should  meet  current  safety
standards and be fitted with a 30 mA circuit breaker.
- The steriliser should be installed in a dry and well ventilated site.
- Never submerge the steriliser in water and never use in wet places.
- If  the  steriliser  falls  into  water,  unplug  it  from  the  power  supply
before touching it.
- Never  use  the  steriliser  if  it  is  dropped  into  water:  take  it  to  the
VIVOG  technical  assistance  centre  for  inspection  and  repair  if
necessary:

VIVOG  SAS 

2 Rue de la Briaudière

 -  BP  4000

1

37515  BALLAN-MIRÉ  CEDEX  - FRANCE. 
Tel.: +33 (0)2 47 73 38 38 – Fax. +33 (0)2 47 73 38 48 
E-mail[email protected]

- If  the  steriliser  stops  working  or  does  not  work  correctly,  turn  it  off
and  do  not  open  it.  Repairs  should  only  be  performed  at  the  VIVOG 
technical assistance centre.
- If the power cable is damaged, it should be replaced with an identical
model.
- Never use the steriliser if it is damaged or if there are missing parts.
- Never use the steriliser with wet hands or feet.
- Never use the steriliser barefoot.
- Never use the extension lead in rooms that are destined for bathing or
showering.
- Never  pull  the  power  cable  or  the  steriliser  to  unplug  it  from  the
power socket.
- Never allow children or unskilled persons to use the steriliser without
supervision.
- Never  open  the  door  of  the  steriliser  without  making  sure  that  it  is
turned off.
- Never use the steriliser for anything other than the purpose for which
it is designed.
- This machine is not designed to be used by people (including children)
whose physical, sensory, or mental capacities are reduced, or by anyone
without  the  necessary  skills  or  knowledge,  unless  they  are  specifically
monitored  or  have  been  instructed  in  the  use  of  the  machine  by
somebody responsible for their safety"
- Children should be monitored to ensure that they do not play with the
machine.

NEVER OPEN THE MACHINE 

Use: 

- Make sure that the steriliser is  stable before operation. The steriliser
should be turned off before opening the door.
- Only  use  the  cable  supplied  and  plug  it  into  an  electric  socket  that
complies with current regulations.
- Instruments  should  be  cleaned  and  dried  before  being  placed  in  the
steriliser.
- The  “4-in-1”  OPTIMUM  spray  is  ideal  for  cleaning  the  instruments
prior to sterilisation (optional extra).
All optional extras are available from your reseller or on request by e-
mail fro[email protected].
- Place  the  cutting  instruments  on  the  steriliser  making  sure  that  they
are  not  overlapping  one  another,  and  making  sure  that  all  scissors  are
opened.- Close the door
- Press  the  ON/OFF  button  to  start  the  steriliser.  The  light  comes  on,
indicating the start of the programme.
- Sterilisation  only  begins  once  the  door  is  closed.  It  stops
automatically as soon as the door is opened.
- The  programme  takes  25  minutes.  At  the  end  of  the  cycle,  turn  the
steriliser off.
- Press the ON/OFF button to turn off the power supply and remove the
cutting instruments.

Cleaning and maintenance: 

- Before cleaning or replacing the light bulb, turn off the steriliser and
remove the plug from the power socket.
- Use a soft damp cloth to clean the inside of the steriliser.
- Do  not  use  inappropriate  cleaning  products  (creams,  solvents,
abrasive products, etc.).

Technical specifications: 

- External dimensions (Lxhxdepth): 

35 x 22 x 21 cm

- Net weight: 

6 Kg  - 220V - 50 Hz – 185 W -  Capacity : 13 L

- Inner temperature : 40°C +/- 10°C

Guarantee; 

The steriliser is guaranteed for a period of 12 months from the date  of 
purchase, the guarantee terminates at this time even if the steriliser has 
not  been  used.  It is therefore  advisable to  keep  the  proof  of  purchase 
(receipt and original packaging). 
The  guarantee  is  applicable for normal conditions of  use  and  not 
intensive, on clean materials with regular maintenance of the steriliser. 
The  guarantee  covers all  mechanical and  electrical manufacturing 
defects.  
The  replacement or repair of  parts subjected  to  normal wear,  such  as 
the UV light, are therefore excluded. 
Any  repairs made  during  the  guarantee  period  do  not result  in  a 
prolongation of the latter. 
The guarantee is not valid if the steriliser has been opened or damaged 
as a result of negligence, inexperience, or during transport. 
The replacements or repairs covered by the guarantee are free of charge 
by sending  the  steriliser directly,  in  its original packaging,  with  proof 
of purchase to: 

VIVOG  SAS 

2 Rue de la Briaudière

 -  BP  40001

37515  BALLAN-MIRÉ  CEDEX  - FRANCE. 
Tel.: +33 (0)2 47 73 38 38 – Fax. +33 (0)2 47 73 38 48 
E-mail[email protected]

Shipping costs are at the expense of the purchaser.

 

Use: worktop 

VIVOG SAS

2 Rue de la Briaudière – CS 40001 

37515 BALLAN-MIRE CEDEX – FRANCE

tel. +33 (0)2 47 73 38 38 - fax. +33 (0)2 47 73 38 48 

email : [email protected] 

Reviews: