VITRIKO
Mobile Data Experts
1. CONFIGURATION OVER WEB BROWSER
1.31
USB port configuration
The USB port configuration can be called up by airbrush option
USB Port
in menu. Con-
figuration can be done, if we have USB/RS232 converter.
Item
Description
Baudrate
Applied communication speed.
Data Bits
Number of data bits.
Parity
Control parity bit:
•
none
– will be sent without parity
•
even
– will be sent with even parity
•
odd
– will be sent with odd parity
Stop Bits
Number of stop bit.
Split Timeout
Time to rupture reports. If you receive will identify the gap between
two characters, which is longer than the parameter value in millisec-
onds. Then all of the received data compiled and sent the message.
Protocol
Communication protocol:
•
TCP
– communication using a linked protocol TCP
•
UDP
– communication using a unlinked protocol UDP
Mode
Mode of connection:
•
TCP server
– router will listen to incoming requests about TCP
connection
•
TCP client
– router will connect to a TCP server on the speci
fied IP address and TCP port
Server Address
In mode TCP client it is necessary to enter the Server address and
final TCP port.
TCP Port
In both modes of connection is necessary to specify the TCP port on
which the router will communicate TCP connections.
Table 70: USB port configuration 1
After check
Check TCP connection
, it activates verification of established TCP connection.
83
Contact www.vitriko.com [email protected]