Please read the following information before operating. 

2.1

 

Maintenance 

Please abide by the following rules while storing or using this product: 

2.1.1

 

Keep dry: do not place the product in a humid environment. Dry surroundings 
help extend the life of the product. 

2.1.2

 

Avoid temperature shock: temperature shock (for example, taking the product 
into a warm room from a cold environment) will cause internal condensation 
inside  the  machine.  Please  put  the  device  inside  the  protection  bag  or 
handbag  to  prevent  temperature  shock,  and  avoid  using  the  device  in  an 
environment with extreme temperatures. 

2.1.3

 

Avoid dropping: the device may malfunction if it encounters strong collision, 
vibration, or distortion. 

2.1.4

 

Turn  the  microscope  off  before  cutting  off  the  power  supply  :do  not  forced 
cut off the power supply. 

2.1.5

 

Do not face the lens against strong light or sunshine for extended periods of 
time:  Strong  light  rays  may  degrade  sensitive  elements  and  generate  white 
stains on images. 

2.1.6

 

Handle  the  device  carefully:  do  not  disassemble  cables  forcefully  and  avoid 
contact with the lens since they are subjected to damage. 

2.1.7

 

Make sure to switch the power supply off and unplug the power cable if the 
device is not in operation for an extended period of time. Store the device in a 
dry environment with excellent ventilation. Do not expose the machine in an 
environment lower than -5ºC or higher than 50ºC. 

2.1.8

 

While carrying, put the device inside the box to prevent from being damaged.

 

Summary of Contents for UM08D-CSZ064

Page 1: ...Version 1 0A UM08D CSZ064 User s Guide...

Page 2: ...ntents 2 1 2 D CSZ064 Lens Assembling 2 1 3 IR Remote controller 5 1 4 Microscope menu functions 8 1 5 Microscope introduction 22 1 6 Microscope Focus 26 1 7 Microscope accessory 28 2 Printed Notice 2...

Page 3: ...1 D CSZ064 Lens 1 Stand AssembleGuide 1 LED Ring Light GN03 1 1 2 D CSZ064 Lens Assembling 1 2 1 Fix microscope Each D CSZ064 lens has reach its parfocal distance when goods ship out simply screw the...

Page 4: ...3 1 2 2 Start to use microscope Connect the HDMI cable c and adaptor d included in box to HDMI monitor and power See below b a...

Page 5: ...4 1 2 3 Power On Off Press Power to turn on microscope Choose HDMI mode or Auto on HDMI monitor to output image c d...

Page 6: ...when connect to optional accessory Image Capture Box IMB05 for snapshot 5 LED Adjustment No Function 6 Motor Reset Recalibrates entire operation Returns to the lens position If a loss of electricity o...

Page 7: ...lease refer to Section 1 6 Microscope Focus Press button one time to search focus in current area press and hold button for 2 seconds to search focus in whole area 8 1 Single Autofocus Focuses one tim...

Page 8: ...ill show OZ sensor position and EV Exposure Each status only shows up 3 seconds 17 Auto White Balance Calibration To calibrate the white balance place the white balance card included in box under the...

Page 9: ...4 Microscope menu functions There are 8 functions in menu press Up and Down to choose item Left and Right to turn on off or adjust parameter Enter means more functions press Menu to enter next functio...

Page 10: ...Control auto control the brightness based on setting when light is not enough 3 SENS UP Only available when item 2 AGC value is larger than 0 use to increase Senor to light s sensibility 4 Brightness...

Page 11: ...ear the edge of defog area 6 3 DEFAULT Return to default setting 6 4 RETURN Return to last page 1 4 2 BACKLIGHT Press left right button to choose turn on off Backlight mode 1 OFF Disable backlight fun...

Page 12: ...o last page 3 BLC Back Light Compensation To adjust brightness for darker image in back light environment 3 1 GAIN To adjust brightness level 3 2 AREA Choose the back light compensation area and size...

Page 13: ...ng the area 4 1 SELECT Select the areas which needs to be adjusted 4 areas are selectable 4 2 DISPLAY Display the selected area 4 3 LEVEL Set value to judge if the image is too bright 4 4 MODE Super b...

Page 14: ...hite balance 2 ATW Auto tracing white area and calibration 3 AWC SET Semi auto white balance Use to track the white color from current image 4 MANUAL Manually adjust blue and red values to find correc...

Page 15: ...D NR 3 1 1 SMART NR The sensitivity to detect the moving object The lower value gets higher sensitivity 3 1 2 RETURN Return to last page 3 2 LEVEL The threshold to judge noise 3 3 START AGC Start auto...

Page 16: ...turn Return to last page 1 4 5 SPECIAL Set special functions 1 D EFFECT There are few more functions in D EFFECT but 1 3 1 4 and 1 6 function can only turn on one item at one time Press Left or right...

Page 17: ...2 MIRROR Image rotatory Horizontal or Vertical 1 3 D ZOOM Digitally enlarge the chose area Digital zoom selection can from 1 62 times See below setting for D Zoom 1 3 1 PIP Turn on Picture in Picture...

Page 18: ...DEFAULT Return to default setting 1 3 5 RETURN Return to last page 1 4 SMART D ZOOM Assign 1 or 2 areas to enlarge the image from 1 62 times whenever detected the object moves The Smart D zoom will au...

Page 19: ...rea can be set in 1 4 1 1 4 3 SENSITIVITY The sensitivity to detect whenever objects move The lower value gets the higher sensitivity 1 4 4 PIP No Function 1 4 5 D Zoom Set magnification times 1 4 6 T...

Page 20: ...Select the areas which need to be detected 4 areas are selectable 2 2 DISPLAY Display the selected area Position and area can be set in 2 1 2 3 SENSITIVITY The sensitivity to detect whenever objects...

Page 21: ...Pixel Correction Correct the live dead pixel during preview 4 1 2 LEVEL Set the threshold value to judge if it needs RETURN Return to last page 4 2 STATIC DPC Static Dead Pixel Correction scan and fi...

Page 22: ...compensate the dead pixel 4 2 4 AGC Auto Gain Control When light is not enough AGC will follow the threshold setting to compensate the dead pixel 4 2 5 RETURN Return to last page 5 VERSION Firmware ve...

Page 23: ...ctory default setting Press Left right button to choose CHANGE to return default 1 4 8 RETURN Exit from menu 1 5 Microscope introduction 1 5 1 IR Remote Area Indicator When both f and g LED indicator...

Page 24: ...blink whenever buttons are pressed If the indicator did not blink means the signal was not delivered and please repress again 2 HDMI indicator f When lit up the microscope is in HDMI mode If light bli...

Page 25: ...ed to connect the microscope to a screen When the device is in HDMI mode connect the microscope to the screen using the HDMI cable from the box For TV screen connections make sure to choose the homolo...

Page 26: ...tor Assembling Assemble the stand first Insert D CSZ064 lens into Ring Adaptor and screw tight with Hex Key Insert lens with Ring adaptor into Universal Adaptor then screw tight k the lens face front...

Page 27: ...erclockwise 3D lens part to 3D lens m 1 6 Microscope Focus 2D Image Observation Move the D CSZ064 lens upward leave WD80mm from the object press Zoom out button move the sensor to end position Turn th...

Page 28: ...f clear at each stage the focus is done If the image is not clear at each magnification please re try from beginning 3D Image Observation Turn the optical zoom to 0 6x and Switch the 3D lens part p to...

Page 29: ...D CSZ064 on 24 Reference data Adaptor 0 5X Objective 0 75X Working Distance mm 80mm 2D view Working Distance mm 30mm 3D view Optical Zoom 0 6x 1x 2x 3x 4x FOV mm 23 7 14 5 7 3 4 9 3 6 Mag X 22x 36x 72...

Page 30: ...lfunction if it encounters strong collision vibration or distortion 2 1 4 Turn the microscope off before cutting off the power supply do not forced cut off the power supply 2 1 5 Do not face the lens...

Page 31: ...t GN 03 DC Port Adaptor DC Input HDMI Port Output 1080P 1920 1080 Pixel image Focus Control IR remote control Power Supply Adaptor Output DC 5 0V 2 0A Input AC 100 240V 50 60Hz Power Consumption A C 0...

Page 32: ...the device or the device is dropped or damaged please switch off and remove the power supply to avoid fire and electric shock Do not look steadily into Light sources after switching on the host as it...

Page 33: ...er etc Services caused by any of the following situations in the period of the warranty shall not be provided free of charge 1 Improper use or disassembly repair or refitting 2 Any damages to the devi...

Page 34: ...for Confirmation Stamp is necessary for validation of the Warranty Distributor s seal shall include name of the shop telephone and address Please ask the distributor to fill in the name of the shop ad...

Page 35: ......

Page 36: ...HTTP WWW VITINY COM MicroLinks Technology Corp All rights reserved...

Reviews: