9
ENGLISH
Note:
-
Be careful - there can be water inside the
cartridge body.
-
Also water can remain at the installation
place of cartridge. Remove the remaining
water from the installation place with a
dry cloth or paper tissue before installing
a new cartridge.
1.
Install a new water softening cartridge to its
place (pic. 15).
2.
Install the water tank (16) to its place (pic. 3).
STORAGE
–
Before taking the iron away for storage, make
sure that it has cooled down completely.
–
Pour the remaining water out of the water
tank, and in case of long storage, pour the
water out of the water softening cartridge
and the boiler.
–
Clean the unit.
–
Fix the steam hose (5) at the steam hose rest
(14).
–
Place the iron on base (9).
–
Wind the power cord (20) and fix it with a
fixation strap (19) (pic. 16).
–
Keep the unit away from children in a dry cool
place.
DELIVERY SET
Steam station with iron – 1 pc.
Removable water tank – 1 pc.
Removable water softening cartridge – 1 pc.
Beaker – 1pc.
Instruction manual – 1 pc.
TECHNICAL SPECIFICTAIONS
Power supply: 220-240 V ~ 50 Hz
Maximal power consumption: 2200 W
TROUBLESHOOTING
Failure
Possible Cause
Solution
The iron doesn’t heat
up.
The unit is off.
Switch on the unit by pressing
the button (13) and turn the
temperature control knob (4) on the
iron.
The steam is not
generated.
The unit is off.
Switch on the unit by pressing the
button (13)
Steam intensity knob (12) is set
to the position «steam supply is
off».
Set the knob (12) to the necessary
position.
Not enough water in the water
tank (16).
Fill the water tank (16) with water.
The water leaks from the
steam openings of the
iron soleplate.
Selected temperature mode
is not appropriate for steam
ironing.
Set the temperature of ironing within
the range between «••» and «МАХ».
If you make a long pause
during the ironing, the steam in
the steam hose can cool down
and condensate.
It is normal. Press the steam supply
button (3) while holding the soleplate
(6) away from the clothes, wait till the
steam goes out without water leakage
from steam openings.
Scale and other dirt inside the
boiler.
Wait till the unit cools down completely
and clean the boiler - see «Cleaning
the boiler (18)»
VT-1224.indd 9
03.07.2012 9:13:43
Summary of Contents for VT-1224 B/VT
Page 1: ...Vitek VT 1224 Blue VT 1224 Violet...
Page 2: ...1 VT 1224 B VT Steam station 4 11 19 27 34 41 48 56 64 VT 1224 indd 1 03 07 2012 9 13 42...
Page 3: ...21 15 16 17 18 19 20 5 6 3 4 MAX 2 1 VT 1224 indd 2 03 07 2012 9 13 42...
Page 4: ...7 8 9 10 11 12 13 14 15 16 VT 1224 indd 3 03 07 2012 9 13 42...
Page 21: ...20 3 6 1 1 1 2 6 6 VT 1224 indd 20 03 07 2012 9 13 44...
Page 27: ...26 3 38 7 1070 VT 1224 indd 26 03 07 2012 9 13 44...
Page 29: ...28 3 6 1 1 1 2 6 6 VT 1224 indd 28 03 07 2012 9 13 45...
Page 50: ...49 3 6 1 1 1 2 6 6 VT 1224 indd 49 03 07 2012 9 13 46...
Page 56: ...55 3 89 336 73 23 VT 1224 indd 55 03 07 2012 9 13 47...
Page 58: ...57 i MIN 3 6 1 1 1 2 6 6 VT 1224 indd 57 03 07 2012 9 13 47...
Page 64: ...63 i i 89 336 i i i 73 23 EC 3 6 18 VT 1224 indd 63 03 07 2012 9 13 47...
Page 73: ......