20
3.9 ALARM
Use the
Joystick
to move the cursor and
(Tele/Wide)
to adjust. To save changes highlight ‘SAVE AND
EXIT’ and move
Joystick
right.
Joystick
left exits without saving.
NO
: Alarm input number
PRI(Priority)
: The lower number has higher priority. (0-8)
FUN(function)
: Stored function number to be called by alarm.
IN
: NO/NC - normally open /Closed OFF - ignore
OUT
: OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.
HLD(HOLD)
: Alarm will be held for programmed time (03 to 99 seconds)
LATCH
: ON - Shows all alarms including past alarm.
OFF - Shows activated alarms only.
DWELL
: Dwell time during multiple alarms, 03 to 99 seconds.
The RELAY OUT setup is helpful when the outdoor housing is used with the dome.
Ex. When you connect the relay output of the dome to the heater connector of the outdoor housing, the
relay output can operate during the setting time only.
ALARM:
the relay output is operated during an alarm operation or by the short key of our keyboard.
1-5 MIN(minute):
the relay output is operated during this setting time only by the function run from
the dome menu.
NOTE:
This
1-5 MIN
setting is not operated by an alarm.
NOTE: If you disable Alarm by dip switch, Alarm menu will display the following screen
.
ALARM SETUP
NO PRI FUN IN OUT HLD LATCH
01 1 001 NC OFF 03 OFF
02 2 A01 NO OUT1 03 OFF
03 1 --- OFF OUT1 03 OFF
04 1 --- OFF OUT4 03 OFF
05 1 --- OFF OFF 03 OFF
06 1 --- OFF OUT1 03 OFF
07 1 --- OFF OUT1 03 OFF
08 1 --- OFF OUT4 03 OFF
DWELL : 03
RELAY OUT SETUP
SAVE AND EXIT(ESC TO CANCEL)
RELAY OUT SETUP
OUT1 : ALARM
OUT2 : 1 MIN
OUT3 : ALARM
OUT4 : 5 MIN
EXIT(ESC TO EXIT)