DE9980
1
VMX-150D
/
300D
/
450D
2-Beam Infrared Detectors
Installation Instructions
1
11
1. FEATURES
. FEATURES
. FEATURES
. FEATURES
•
State-of-the-art circuit
•
Durable housing
•
Dual photoelectric beam sensor
•
Minimum false alarms
•
Indoor and outdoor use
•
Excellent immunity to freezing, snow, rain, fog, and other
bad weather conditions
•
Anti-frost design
•
N.C. tamper switch included
Note:
The
VMX-150D / 300D / 450D
are designed to detect
movement of an intruder. However, note that environmental
disturbances in the protected area may also cause the sensor to
create an alarm. Test the detector periodically for continuous
satisfactory operation before arming the alarm system.
Figure 1.
General View
Figure 2.
Inside View
2
22
2. SPECIFICATIONS
. SPECIFICATIONS
. SPECIFICATIONS
. SPECIFICATIONS
Outdoor Usable Distance:
25 / 50 / 75 m (82 / 164 / 246 ft)
Indoor Usable Distance:
50 / 100 / 150 m (164 / 328 / 492 ft)
Beam:
Infrared photoelectric, 1 kHz, 940 nm infrared pulse
Interrupt Time
: Adjustable from 50 ms to 500 ms.
Power Input
: 10 to 24 VDC
Current (mA):
55 (VMX-150D) / 60 (VMX-300D) / 65 (VMX-450D)
Alarm Output:
N.C., 30 VDC, 1 A max., 1 s
Transmitter LED:
Green (indicates transmit)
Receiver LEDs:
Red (indicates alarm) and green (indicates standby)
Align Angle:
± 5° vertical. ± 90° horizontal
Temperature:
-25 to 60°C (-13 to 140°F)
Mounting:
Wall or pole (pole clamps and screws included)
Size:
67 X 167 X 66.5 mm (2.64 X 6.57 X 2.62 in.)
Wire Connection:
Screw-type terminals
Case:
PC, ABS plastic, waterproof
Tamper:
N.C., becomes N.O. when cover is removed
Figure 3.
Dimensions
3
33
3. INSTALLATION
. INSTALLATION
. INSTALLATION
. INSTALLATION
Avoid
blocking objects
Avoid direct sunlight and keep the
max. detecting range as prescribed
Do not mount unit on un-
secure or non-solid surface
When installing several units,
mount as shown above
3.1 Mounting
A. Wall Installation
( 1 )
Loosen the cover locking screw and remove the cover. Loosen
the unit setting screw at the lower part of the unit. Slide the
mounting plate downwards and remove it.
( 2 )
Feed the wires through the wiring holes of the mounting plate
before fixing the plate to the wall.
( 3 )
Fix the mounting plate firmly on the wall with the mounting
screws supplied.
B. Pole Installation
( 1 )
Use a 43 mm (1.66”) mounting pole
( 2 )
Fix the clamps onto mounting plate with supplied screws. Place
the clamps around the pole and tighten firmly with the pole
locking screws.
( 3 )
Feed the wires through the wiring hole of the mounting plate
.
Figure 4.
Pole Clamps
Figure 5.
Mounting Plate