DE1029
1
NEXT PIR
NEXT PIR
NEXT PIR
NEXT PIR
Digital PIR Detector with TMR™ Signal Processing
Installation Instructions
1
11
1. INTRODUCTION
. INTRODUCTION
. INTRODUCTION
. INTRODUCTION
The NEXT PIR is a microprocessor-controlled PIR detector,
designed for easy installation, free of vertical adjustment. It features
a cylindrical lens with uniform detection sensitivity beginning at 0.5
meter away from the detector up to a distance of 12 meters (40 ft).
The advanced
True Motion Recognition™
algorithm (patented)
allows the NEXT PIR to distinguish between the true motion of an
intruder and any other disturbances which cause false alarms.
A TST (Test) input permits switching the detector to the walk test
mode remotely without removing the front cover. An on-board
motion event jumper determines whether 1 or 2 consecutive
motion events would trigger an alarm.
Figure 1.
General View
Figure 2.
Inside View
2
22
2. SPECIFICATIONS
. SPECIFICATIONS
. SPECIFICATIONS
. SPECIFICATIONS
Input Voltage:
9 to 16 VDC
Current Drain:
About 8 mA @
12 VDC
OPTICAL (see Figure 3)
Lens Data
No. of curtain beams:
9 + 5
Max. Coverage:
12 x 12 m
(40 x 40 ft) / 90°
ALARM and TAMPER
Alarm Output:
Solid-state relay,
N.C., up to 100 mA / 30 V, ~30
Ω
internal resistance. Circuit opens
for 2-3 seconds upon alarm.
Alarm Indication:
LED lights
for 2-3 seconds.
Figure 3.
Coverage Pattern
Event Counter:
Selectable, 1 or 2 motion events
Tamper Contacts
: Normally closed, 50 mA resistive / 30 VDC
MOUNTING
Surface or corner, at the height of 1.8 to 2.4 m (6 to 8 ft)
Note:
Base allows single-sided corner mount at 45° to wall.
ACCESSORIES:
BR-1:
Surface mounted swivel bracket, adjustable 30° down and
45° left/45° right.
BR-2:
BR-1 with a corner adapter
BR-3:
BR-1 with a ceiling adapter
ENVIRONMENTAL
Operating Temperature: –
10°C to 50°C (14°F to 122°F)
Storage Temperature:
–20°C to 60°C (–4°F to 140°F)
RFI Protection:
Greater than 20 V/m (20 MHz to 1000 MHz)
PHYSICAL
Size
(H
x
W
x
D):
94.5 x 63.5 x 49.0
mm
(3-11/16
x 2-1/2
x
1-15/16”)
Weight:
Approximately 50 g (1-3/4 oz)
PATENTS:
U.S. Patents 5,693,943
!
6,211,522
!
D445,709
(another patent pending)
3
33
3. INSTALLATION
. INSTALLATION
. INSTALLATION
. INSTALLATION
3.1 General Guidelines
3.2 Illustrated Installation Procedure
1
2
Open holes in base
Disassemble unit