background image

DE1821

1

DUO

 

200

Dual-Technology Microwave/PIR Intrusion Detector

Installation Instructions

1

11

1. INTRODUCTION

. INTRODUCTION

. INTRODUCTION

. INTRODUCTION

DUO

 

200

 

is

 

a

 

state-of-the-art

 

microcomputer controlled dual-

technology intrusion detector. Its operation is based on two
physical phenomena - the infrared (IR) radiation emitted by the
human body and the Doppler frequency shift caused by a person
moving in a microwave (MW) field. The IR and MW technologies,
when combined in a single detector, complement each other to
assure the most reliable detection and immunity to false alarms.
The superiority of the DUO 200 over other dual detectors has
been achieved by the advent of the

 True Motion Recognition™

algorithm

 

(patented). This advanced motion analysis method

provides the DUO 200 with the ability to distinguish between the
true motion of a human body and any other disturbances which
invariably cause false alarms.
Another unique feature of the DUO 200 is the 

MW Motion

Simulator

 circuit (patents applied for), which simulates the effect

created by a human body moving in the MW field. The simulation
routine is carried out periodically for self-testing, supervision and
assurance that the MW detector operates properly.

Figure 1.

 DUO 200 General View

2

22

2. SPECIFICATIONS

. SPECIFICATIONS

. SPECIFICATIONS

. SPECIFICATIONS

Input Voltage:

 9 to 16 VDC

Current Drain:

 About 23 mA @ 12 VDC

PIR SECTION (see Figure 2)
Detector:

 Low noise dual-element pyroelectric sensor

Trip Indication:

 Green LED flashes for up to 5 seconds

True Motion Event Verification Counter:

 Selectable, 1 or 2

motion events

Lens Data

No. of Beams:

 34

Field of View: 

90°

Max. Coverage: 

12 x 12 m (40 x 40 ft)

Vertical Adjustment: 

+2° to –12°, by  sliding  the circuit board

along a calibrated scale.

MW SECTION
Oscillator:

 Microstrip DRO-stabilized type

Frequency:

 10.525 GHz in the USA, 2.45 GHz in the UK and

Europe (

2.45 GHz has no restriction in any EU member state).

Detection Range:

 Adjustable from 25% to 100% (3 m to 12 m)

Trip Indication:

 Green LED illuminates for up to 5 seconds

ALARM, TAMPER & TROUBLE DATA
Alarm Indication:

 Red LED illuminates for 1.3 to 5 seconds if

both detectors trip

Relay Contacts:

 Normally closed, 0.1 A resistive/30 VDC; 18 

resistor in series with contacts

Alarm Duration: 

1.3 to 5 seconds (red LED lights and output

relay contacts open)

Tamper Contacts

: Normally closed, 0.1A resistive / 30 VDC

Trouble Output:

 Open-collector, 100 mA max., with 47 

resistor in series  

PHYSICAL CHARACTERISTICS
Dimensions (H x W x D):

 104  x 60 x 32 mm (2.4 x 4.1 x 1.3 in.)

Weight:

 80 g (2.8 oz)

MOUNTING
Direct:

 Surface or corner without bracket, up to 2.5 m (8 ft)

Figure 2. 

PIR and MW Coverage Pattern  

ACCESSORIES (see Figure 4)
BR-1:

 Surface mounted swivel bracket, adjustable 30° down and

45° left/45° right.

BR-2:

 BR-1 with a corner adapter (kit)

BR-3:

 BR-1 with a ceiling adapter (kit)

ENVIRONMENTAL CONDITIONS
Operating Temperature: 

–10°C to 50°C (14°F to 122°F)

Storage Temperature:

 –20°C to 60°C (–4°F to 140°F)

RFI Protection:

 Greater than 30 V/m (20 MHz to 1000 MHz)

PATENTS
U.S. Patents:

 5,237,330 and 5,693,943; Des. 346,567

ATTENTION!

 

Detection occurs only in areas in which the MW and PIR patterns overlap

Summary of Contents for DUO 200

Page 1: ... Indication Green LED flashes for up to 5 seconds True Motion Event Verification Counter Selectable 1 or 2 motion events Lens Data No of Beams 34 Field of View 90 Max Coverage 12 x 12 m 40 x 40 ft Vertical Adjustment 2 to 12 by sliding the circuit board along a calibrated scale MW SECTION Oscillator Microstrip DRO stabilized type Frequency 10 525 GHz in the USA 2 45 GHz in the UK and Europe 2 45 G...

Page 2: ...nockouts at the middle of the base For corner mounting use two diagonally opposite knockouts at the angled sides of the base see Figure 3 2 To route the wiring to a lower conduit use the two wiring knockouts at the bottom of the base see Figure 3 To route the wires under the base towards the ceiling use the wiring channel and its associated knockout C Select the mounting location in accordance wit...

Page 3: ...n event trips the PIR ON ON Two motion events trip the PIR SW 2 OFF Alarm walk test is disabled ON ON Alarm walk test is enabled SW 3 OFF MW PIR walk test is disabled ON ON MW PIR walk test is enabled SW 4 OFF Output relay opens upon alarm OFF ON Output relay opens upon alarm and when trouble is detected Setting SW 2 and SW 3 to OFF does not disable the trouble indication flash flash 3 8 Adjusting...

Page 4: ... equipment WARRANTY WARRANTY WARRANTY WARRANTY Visonic Ltd and or its subsidiaries and its affiliates the Manufacturer warrants its products hereinafter referred to as the Product or Products to be in conformance with its own plans and specifications and to be free of defects in materials and workmanship under normal use and service for a period of twelve months from the date of shipment by the Ma...

Reviews: