1-4 About the DXL5000
DXL5000 User and Technical Manual
1.2 DXL5000 Receiver Displays and Connections
The following figure and associated table shows the DXL5000 receiver displays and
connections.
1
RSL dBm
LCD display
Indicates the current receiver signal power level in dBm.
2
ALARM
LEDs
•
MAJOR ALARM
—Indicates a condition that can interrupt
service.
•
MINOR ALARM
—Indicates a condition that should be
remedied but does not interrupt service.
•
SCM ALARM
—Indicates a problem with the single carrier
modulator.
See
3
POWER IN
AC power connector
Provides AC power to the unit.
4
AC power fuse
Provides input power overload protection.
5
MGMT
RJ
-
45 connector
Provides 10 Base T Ethernet connection via your web browser
to a PC at a local or remote location for control of the unit.
6
IF OUT
75 Ohm BNC female connector
The
IF OUT
connector provides the 70 MHz IF output from the
unit.
7
SUMMARY ALARM
15
-
pin male D
connector
Provides summary alarm data for common faults and events.
8
CHAN 1
and
2 DATA
RJ
-
45 connector
Provides 10/100 Base T Ethernet connections to the unit.
CHAN1
is the customer connection;
CHAN2
is the inter-unit
connection.
9
CHAN1
and
CHAN2 T1/E1
RJ
-
45 connector
Provides 2 channels of either T1 or E1 outputs from the unit.
10
ASI/DS3/E3 1
and
2
75 Ohm BNC female connector
Provides 2 ASI or 2 DS3/E2 outputs from the unit.
11
Ground
Provides grounding for the DXL5000.
12
DIV IN
75 Ohm BNC female connector
Provides the diversity receive input to the unit.
1
2
3
5
4
6
7
8
9
10
13
12
14
16 17 18
11
15