![Visionary Solutions Duet D-2 User Manual Download Page 52](http://html1.mh-extra.com/html/visionary-solutions/duet-d-2/duet-d-2_user-manual_1032352052.webp)
Visionary, Network Audio Video
49
D
UET
E-2/DuetD-2 U
SER
M
ANUAL
T
ROUBLESHOOTING
4. Click
Factory Default
.
5. Click
OK
on the pop-up.
6. The unit will reset to its factory default settings.
Method 2:
1. Locate the reset button on the bottom side of the Duet-2.
2. Use a paperclip or similar device to press physical reset button.
3. Press and hold the reset button until the LEDs on the front of the Duet-2 indicate the unit has been reset (Fast Link LED).
4. The unit will reset to its factory default settings.
D
IAGNOSTICS
P
AGE
Every encoder and decoder have a diagnostics page that is accessible via the web UI. To access the diagnostics page, type the
following address into a web browser: http://admin:admin@<unit IP address>/diagnostics.html. The diagnostics page provides the
following information:
N
ETWORK
I
NFO
Displays the current network link speed for Stream, Dante, Uplink, and expansion port. In addition, the network info displays local
and neighbor LLDP information.