background image

www.visionsecurity.com.tw

Installation & Operation Manual

Product Description and Specification:

Introduction

Thanks for choosing the Vision’s wireless Arrival Sensor of 

the home security device. This sensor is a Z-Wave™ PLUS 

enabled device (interoperable, two-way RF mesh networking 

technology) and is fully compatible with any Z-Wave™ 

enabled network and it’s security framework. Every mains powered 

Z-Wave PLUS enabled device acts as a signal repeater and multiple 

devices result in more possible transmission routes which helps eliminate 

“RF dead-spots”
Z-Wave™ PLUS enabled devices displaying the Z-Wave™ PLUS logo can 

also be used with it regardless of the manufacturer, and ours can also be 

used in other manufacturer’s Z-Wave™ PLUS enabled networks. This 

sensor assigns everyone with an unique ID then you could take care of 

your family to send you any instant notification when they are coming 

home or leaving home, also you could interact some specific scenarios 

with specific persons  When the device is secure included into Z-Wave 

network, above communication will be encrypted.  ARRIVAL SENSOR 

supports SECURITY S0 / SECURITY S2 UNAUTHENTICATED / 

SECURITY S2 AUTHENTICATED.

Limited Warranty

Vision Guarantees that every wireless Arrival Sensor is free from physical 

defects in material and workmanship under normal use for one year from 

the date of purchase. If the product proves defective during this one-year 

warranty period, Vision will replace it free of charge. Vision does not issue 

any refunds. This warranty is extended to the original end user purchase 

only and is not transferable. This warranty does not apply to: (1) damage 

to units caused by accident, dropping or abuse in handling, or any 

negligent use; (2) units which have been subject to unauthorized repair, 

taken apart, or otherwise modified; (3) units not used in accordance with 

instruction; (4) damages exceeding the cost of the product; (5) transit 

damage, initial installation costs, removal cost, or reinstallation cost. For 

information on addtional devices, please visit us at 

www.visionsecurity.com.tw

Federal Communications Commission Statement

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject 

to the following two conditions: (1) This device may not cause harmful 

interference, and (2) This device must accept any interference received, 

including interference that may cause undesired operation.

FCC Caution

“the user that changes or modifications not expressly approved by the 

party responsible for compliance could void the user's authority to operate 

the equipment.”

FCC Statement in User’s Manual (for calss B) FCC Section 15.105 

“Federal Communications Commission (FCC) Statement”

This equipment has been tested and found to comply with the limits for a 

class B digital device, pursuant to Part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference 

in a residential installation. This equipment generates uses and can 

radiate radio frequency energy and, if not installed and used in accordance 

with the instructions, may cause harmful interference to radio communica-

tions. However, there is no guarantee that interference will not occur in a 

particular installation. If this equipment does cause harmful interference to 

radio or television reception, which can be determined by turning the 

equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

- Reorient or relocate the receiving antenna.

- Increase the separation between the equipment and receiver.

- Connect the equipment into an outlet on a circuit different from that to

   which the receiver is connected.

- Consult the dealer or an experienced radio/TV technician for help.

Specification:

Package Content

Protocol: Z-Wave™ (ZM5101)

Frequency Range: 

865.22MHz (ZA1501IN-5)

868.42MHz (ZA1501EU-5)

869.00MHz (ZA1501RU-5)

908.42MHz (ZA1501US-5)

916.00MHz (ZA1501IL-5)

919~923MHz (ZA1501KR-5)

919.80MHz (ZA1501HK-5)

922~926MHz (ZA1501JP-5)

921.42MHz (ZA1501BR-5)

Operating Range: Up to 100 feet line of sight

Operating Temp.: -10°C~ 60°C (14°F ~140°F)

1pc Arrival Sensor

1pc Micro USB Cable

1pc Operation Manual

Operating Range: Up to 100 feet line of sight

Operating Temp.: -15°C~ 60°C (5°F ~140°F)

Z-Wave Command Classes:

COMMAND_CLASS_ASSOCIATION_GRP_INFO  

COMMAND_CLASS_ASSOCIATION_V2   

COMMAND_CLASS_BATTERY

COMMAND_CLASS_CONFIGURATION              

COMMAND_CLASS_DEVICE_RESET_LOCALLY    

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4   

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

COMMAND_CLASS_NOTIFICATION_V8         

COMMAND_CLASS_POWERLEVEL              

COMMAND_CLASS_SECURITY                

COMMAND_CLASS_SECURITY_2              

COMMAND_CLASS_SUPERVISION        

COMMAND_CLASS_TRANSPORT_SERVICE_V2    

COMMAND_CLASS_VERSION_V3              

COMMAND_CLASS_WAKE_UP_V2  

COMMAND_CLASS_ZWAVEPLUS_INFO_V2

Z-Wave S2 Support Command Classes :

COMMAND_CLASS_ASSOCIATION_V2

COMMAND_CLASS_ASSOCIATION_GRP_INFO

COMMAND_CLASS_BATTERY

COMMAND_CLASS_CONFIGURATION

COMMAND_CLASS_DEVICE_RESET_LOCALLY

COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4

COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2

COMMAND_CLASS_NOTIFICATION_V8

COMMAND_CLASS_POWERLEVEL

COMMAND_CLASS_VERSION_V3

COMMAND_CLASS_WAKE_UP_V2

Notification V8 Type:

TYPE

System (0x09)

Heartbeat (0x05)

Timer Ended (0x02)

Clock (0x0B)

(Table 1)

Notification Type

EVENT

V1 Alarm:

0x09

V1 Alarm Type

0x0B

VALUE

0xFF

0x00

TYPE

(Table 2)

1

Parameter 1

VALUE

1 ~ 255 (unsigned decimal) Seconds

(default: 2 (=16seconds x 2))

BYTE

Configuration Command Class:

(Table 3)

ZA1501-5   V0    1080227 6B1Z-15RS2

Arrival Sensor

ZA1501IN-5
ZA1501EU-5
ZA1501RU-5
ZA1501US-5
ZA1501IL-5
ZA1501KR-5
ZA1501HK-5
ZA1501JP-5
ZA1501BR-5

(P.S.: This is the definition how long ZA1501-5 will contact Gateway for 

having a synchronic information. The basic interval time is 16 seconds, 

the synchronic time will be the basic interval time by Parameter 1’s value.)