S

 This device is a wireless Z-Wave sensor. Exclusion, Inclusion and wakeup are confirmed by hitting the 

programm button.

Please refer to the chapters below for detailed information about all aspects of the products usage.

What is Z-Wave?

This device is equipped with wireless communication complying to the Z-Wave standard. Z-Wave is the 

international standard for wireless communication in smart homes and buildings. It is using the 

frequency of 868.42 MHz to realize a very stable and secure communication. Each message is reconfirmed 

(two-way communication) and every mains powered node can act as a repeater for other nodes (meshed 

network) in case the receiver is not in direct wireless range of the transmitter.

Z-Wave differentiates between Controllers and Slaves. Slaves are either sensors (S) transmitting metered or 

measured data or actuators (A) capable to execute an action. Controllers are either static mains powered 

controllers (C) also referred to as gateways or mobile battery operated remote controls (R). This results in a 

number of possible communication patterns within a Z-Wave network that are partly or completely supported 

by a specific device.

1. Controllers control actuators
2. Actuators report change of status back to controller
3. Sensors report change of status of measured values to controller
4. Sensors directly control actuators

(c) 2016 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 1 

Summary of Contents for VIS_ZS6101

Page 1: ...communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referr...

Page 2: ...e smoke sensitivity is 0 5 ft 4 ft The smoke detector has a test button and a flashing LED so you always know that the smoke alarm is working correctly The smoke alarm will warn you when the battery is low When the device detects smoke it will give a loud warning sound It will also trigger actions in other Z Wave devices or Z Wave controllers to escalate the alarm The Smoke Detector can also activ...

Page 3: ...usion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first Exclusion and Inclu...

Page 4: ...th the device a static controller C is needed in the network This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state Without such a controller communication may become impossible and or the battery life time is significantly decreased This device will wakeup regularly and announce the wakeup state by sending out a...

Page 5: ...vent happens all devices stored in the respective association group will receive a common wireless command Association Groups 1 alarm messages max nodes in group 5 Command Classes Supported Command Classes Battery version 1 Basic version 1 Wake Up version 2 Association version 1 Version version 1 Alarm version 2 Manufacturer Specific version 1 Alarm Sensor version 1 Technical Data Battery Type 3 C...

Page 6: ...ssociation is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product contains batteries Please remove the ...

Reviews: