background image

A-DIF-90x120-IR850-SL

Commissioning

6 COMMISSIONING

6.1 Unpacking

1. Lift the cardboard, together with the device, out of the carton.
2. Fold out the tucked in sides on the bottom of the cardboard.

Loosening the film and forming an insertion pocket.

3. Remove the device out of the insertion pocket.
4. Dispose the packing material.

© Vision & Control GmbH 2019

999.995.573.10-en-1.0

23

Summary of Contents for A-DIF-90x120-IR850-SL

Page 1: ...r Use A DIF 90x120 IR850 SL LED area light diffuse illumination Luminous colour Infrared 850 nm Instructions for Use A DIF 90x120 IR850 SL LED area light diffuse illumination Luminous colour Infrared...

Page 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Page 3: ...186 Product Identification Designation Description A Area light DIF Diffuse cover 90x120 Dimensions light emitting surface 90 mm x 120 mm IR850 Wavelength Infrared 850 nm SL vicolux smart light Flash...

Page 4: ...2 Notices on the device 15 5 Technical Data 16 5 1 General Parameters 16 5 2 Electrical Parameters 18 5 3 Photometric Parameters 20 5 4 Conditions for Operation Storage and Transport 21 5 5 Technical...

Page 5: ...A DIF 90x120 IR850 SL Table of Contents 8 1 Maintenance 31 8 2 Service 32 9 Disposal 33 10 EU Declaration of Conformity 34 Vision Control GmbH 2019 999 995 573 10 en 1 0 5...

Page 6: ...A DIF 90x120 IR850 SL 6 999 995 573 10 en 1 0 Vision Control GmbH 2019...

Page 7: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in poten...

Page 8: ...ions of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device...

Page 9: ...nual and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the mai...

Page 10: ...ces of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medi...

Page 11: ...vice and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric...

Page 12: ...11 Cable with M8 socket 4 pin straight 2 m 1 11 612 Cable with M8 socket 4 pin straight 3 m 1 11 613 Cable with M8 socket 4 pin straight 5 m Connection cable with 4 pin M8 socket and open cable end wi...

Page 13: ...cable M8 4 pin 0 15 m 1 30 208 Adapter cable M8 4 pin 1 m 1 30 211 Adapter cable M8 4 pin 2 m Adapter cable with 4 pin M8 socket and 4 pin PTSM plug 4 x 0 5 mm PUR For connecting vicolux smart light...

Page 14: ...Device view 1 Light emitting surface 2 4 x M4 mounting hole through bore 4 x 6 H7 depth 3 4 mm on both sides 3 4 x M3 mounting hole depth 6 2 mm 4 Connection cable with 4 pin M8 connector 5 Casing 6...

Page 15: ...uctions are provided on the device Type plate A DIF 90x120 XXXX SL Made in Germany www vision control com 1 2 3 Image 2 Type plate 1 Device designation as DataMatrix code 2 Manufacturer information 3...

Page 16: ...without connector Dimensions light emitting surface 90 mm x 120 mm Weight 340 g Degree of protection IP IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Risk group 0...

Page 17: ...Bending radius cable fixed at least 5 x cable diameter Bending radius cable moved at least 10 x cable diameter Bending cycles at least 4 million Robot suitable no Connector Parameter Characteristic Co...

Page 18: ...2 1 A 1 4 8 A 2 Forward voltage ULED at ILED Max 5 6 V 6 8 V Power consumption Ptot 12 0 W 1 Flash mode Pulse mode LED current ILED 20 0 A 2 3 Forward voltage ULED at ILED Max 7 5 V 8 7 V Flash perfor...

Page 19: ...0 20 0 25 0 1 0 E 3 1 0 E 2 1 0 E 1 1 0 E 0 1 0 E 1 1 0 E 2 1 0 5 0 2 0 1 0 05 0 02 D LED current I LED A tON s I LED tOFF tON D tON tON tOFF D tON tOFF Duty Cycle Power on time Power off time Image...

Page 20: ...ral bandwidth 1 30 nm Continuous operation Radiance 85 W m sr 210 W m sr Flash mode Pulse mode Radiance 840 W m sr 1 The values stated are maintained as from an LED current of 0 2 A Spectral Emission...

Page 21: ...original packaging For accessories connected devices and components observe the specific information in the associated instructions for use Ambient Conditions Operation Storage Transport Temperature...

Page 22: ...th 10 on both sides 2 5 21 M8 connector 5 9 4 x M3 depth 6 2 light emitting surface 4 x 6 H7 depth 3 4 4 x M4 through hole on both sides 10 5 3 25 120 135 90 97 4 x M3 depth 10 3 5 30 30 30 3 5 4 15 1...

Page 23: ...together with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard Loosening the film and forming an insertion pocket 3 Remove the device out of the insertion po...

Page 24: ...he device tapped holes are located at the sides 3 2 1 1 3 4 Image 6 Mounting holes 1 4 x M4 tapped hole through bore 4 x 6 H7 depth 3 4 mm on both sides 2 4 x M3 tapped hole Maximum screw in depth 6 2...

Page 25: ...rt light lighting controller is not hot plug capable Connect or disconnect lights during operation may destroy the lights Connect or disconnect lights only if the lighting controller is in the off and...

Page 26: ...t light vicolux Image 8 Connection diagram vicolux smart light Pin Core colour Signal Description 1 BN brown ILED LED anode positive current input 2 1 WH white BD Data Channel for vicolux smart light...

Page 27: ...t light lighting controllers When using a vicolux smart light lighting controller the light is configured via the user interface DLC Server Control Center Refer to the Instructions of Use DLC Server C...

Page 28: ...are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event of dazzlin...

Page 29: ...colux smart light lighting controller NOTICE Damage caused by incorrect connecting and disconnecting The vicolux smart light lighting controller is not hot plug capable Connect or disconnect lights du...

Page 30: ...or continuous operation apply a constant current ILED to the lighting Flash operation For pulse or flash operation apply current pulses ILED to the lighting Observe the specified parameters see Electr...

Page 31: ...utside with a damp cloth Remove excessive dirt with an approved anodised aluminium cleaner Refer to the instructions of the cleaner The connectors must be clean and dry before the device is connected...

Page 32: ...glad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective devi...

Page 33: ...separately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be don...

Page 34: ...strial environments DIN EN 61000 6 4 2011 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and meas...

Page 35: ...A DIF 90x120 IR850 SL Vision Control GmbH 2019 999 995 573 10 en 1 0 35...

Page 36: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Reviews: