![Vision & Control 4-21-185 Instructions For Use Manual Download Page 20](http://html.mh-extra.com/html/vision-and-control/4-21-185/4-21-185_instructions-for-use-manual_1031466020.webp)
vicosys
®
6300
Technical Data
5.5.2 Digital I/O card ADDI-DATA
The device has an external digital I/O interface 16 IN / 16 OUT, PNP for the configuration
"Digital I/O card ADDI-DATA".
1
Image 11: Expansion "Digital I/O card ADDI-DATA"
(1)
Digital I/O card ADDI DATA, 16 IN/ 16 OUT, PNP
Characteristics
•
Installed by manufacturer
•
PNP-Open Collector
•
Connector: 37-pin D-Sub connector
5.5.2.1 Digital input channels
GND-IO
IN-X
INx
GND
GND
Image 12: Schematic layout of digital input channels 1 to 16
Characteristics
•
Polarity protection
•
Galvanic decoupled
•
Inputs have ESD protection and interference signal filter
•
The input channels have a common GND connection (GND-IN)
Parameter
Parameter
Min
Nom
Max
Number of inputs
16
Input v VIN (DC)
0 V
24 V
30 V
(1)
Input voltage “Low”
0 V
14 V
Input voltage "High"
19 V
30 V
Input current V
in
= 24 V
2 mA
Input frequency at V
in
= 24 V
5 kHz
Galvanic decoupling
present
(1)
Higher input voltages destroy the respective input channel
20
999.995.428.10-en-2.1
© Vision & Control GmbH 2022