background image

TZB10-B450-HP-24V

Information about the Instructions of Use

1 INFORMATION ABOUT THE INSTRUCTIONS OF

USE

This document contains technical information, important instructions for correct

installation, commissioning and use, as well as product information which were

up-to-date at the time of going to press.
Using this document makes it easier for you to familiarise yourself with the

device and avoid malfunctions caused by improper operation.
The instructions of use and the local regulations and rules must be followed.
To ensure a save and proper application, please read the instructions of use

carefully and keep them for future reference.

1.1 Intended Use

The device is intended exclusively for use as a lighting element for industrial

image processing in automation technology.
The device is not suitable for use in potentially explosive areas.
The device is intended for use in closed rooms.
The device may only be used if it is in technically faultless condition and only

for its intended purpose, and only in accordance with the specifications in this

instructions of use by authorised operative personnel, who are aware of the

safety rules and hazards.
If the device is planned to be used for any other purpose or in a different

environment, the express authorisation of the manufacturer must be obtained

in advance. Any modifications or adaptations required may only be made by

the manufacturer.

© Vision & Control GmbH 2021

999.995.425.10-en-1.6

7

Summary of Contents for 1-33-282

Page 1: ...N CONTROL Instructions for Use TZB10 B450 HP 24V Telecentric Lights Luminous colour Blue 450 nm Instructions for Use TZB10 B450 HP 24V Telecentric Lights Luminous colour Blue 450 nm 999 995 425 10 en...

Page 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Page 3: ...der no TZB10 B450 HP 24V 1 33 282 Product Identification Designation Description TZB Telecentric Lights 10 Luminous field diameter in mm B450 Luminous colour Blue 450 nm HP High power LED 24V 24 V DC...

Page 4: ...TZB10 B450 HP 24V 4 999 995 425 10 en 1 6 Vision Control GmbH 2021...

Page 5: ...Notices on the device 16 5 Technical Data 17 5 1 General Parameters 17 5 2 Electrical Parameters 18 5 3 Photometric Parameters 18 5 4 Conditions for Operation Storage and Transport 19 5 5 Technical Dr...

Page 6: ...TZB10 B450 HP 24V 6 999 995 425 10 en 1 6 Vision Control GmbH 2021...

Page 7: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Page 8: ...ns of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Page 9: ...al and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maint...

Page 10: ...s of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium...

Page 11: ...neral safety instructions are referred to separately at the relevant points in this manual DANGER Possibly hazardous optical radiation emitted from this product Do not look into the lighting when oper...

Page 12: ...Accessories Lens holder Designation Description Order no Lens Holder d35 5 Holder for telecentric lenses and lightings with 35 5 mm clamping diameter for vibration free attachment 2 90 124 Polarizing...

Page 13: ...4 pin straight plug 4A 60V Designation Description Order no Cable M8 4p 4A straight 10m Connection cable with 4 pin M8 socket and open cable end with wire end ferrules 4 x 0 25 mm 4A 60V PUR IP67 str...

Page 14: ...onnection cable with 4 pin M8 socket and open cable end with wire end ferrules 4 x 0 5 mm 5A 30V PUR IP67 straight plug 1 11 614 Extension cable M8 4 pin 5A 30V Designation Description Order no Extens...

Page 15: ...1 Device Views 7 2 3 4 6 6 6 5 1 Image 1 Device view 1 Casing 2 Light emitting surface 3 Identification plate 4 Warning notice 5 Note screw in depth 6 Mounting surface with mounting holes 7 Connector...

Page 16: ...ed on the device Warning notice Image 2 Notice optische Strahlung Type plate Type TZB10 XXXX P 24V SN XXXXXXXX 1 2 Image 3 Type plate 1 Device designation 2 Serial number Notice Screw in depth screw i...

Page 17: ...ions light emitting surface Diameter 11 5 mm Connector Male connector M8 4 pin Weight 96 g Degree of protection IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Risk...

Page 18: ...ut delay tD 50 s 100 s 150 s 5 3 Photometric Parameters Parameter Min Nom Max Peak wavelength peak 451 nm Dominant Wavelength dom 439 nm 455 nm 457 nm Spectral bandwidth 18 nm Full divergence angle 2...

Page 19: ...e the specified ambient conditions when transporting and storing the device For accessories connected devices and components observe the specific information in the associated instructions for use Amb...

Page 20: ...tra e 16 98527 Suhl 1 2 3 4 5 1 2 3 4 5 A A B B C C D D M8 connector TZB10 XXXX P 24V TZB10 XXXX HP 24V l i g h t e m i t t i n g s u r f a c e 1 1 5 3 5 5 2 x M4 depth 6 15 6 15 23 10 58 13 23 33 7 I...

Page 21: ...the tucked in sides on the bottom of the cardboard The film loosens and forms an insertion pocket 3 Remove the device out of the insertion pocket 4 Dispose the packing material 6 2 Mounting the Devic...

Page 22: ...3 Tighten the M5 hexagon nuts alternately hand tight in small steps Mount the Filter adapter slip on adapter 1 2 3 a a a 1 Loosen the M3 threaded pins a of the slip on adapter 2 Attach the slip on ada...

Page 23: ...Label Due to the individual assembly and installation options the device is supplied with the safety label optical radiation After completing all assembly work attach the safety label to the device s...

Page 24: ...cification see data sheet 6 5 1 Pin assignment Use the M8 connector to connect the device according to the pin assignment Pin assignment 1 2 3 4 Image 8 M8 connector 4 pin Connection diagram V GND 1 3...

Page 25: ...you have a known history of epilepsy do not work or stay in areas where there are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly...

Page 26: ...ing the switching signal ON OFF Consider the switching delay time td of the lighting Set the exposure time of the camera to be within the tON range The length of the Power on time tON corresponds to t...

Page 27: ...leaning the optical surfaces NOTICE Follow the specified cleaning sequence Never use dry cloths for cleaning This allows dust and other contaminants to be rubbed into the lens surface thereby damaging...

Page 28: ...lad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Page 29: ...eparately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Page 30: ...TZB10 B450 HP 24V 30 999 995 425 10 en 1 6 Vision Control GmbH 2021...

Page 31: ...al environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and meas...

Page 32: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...