Summary of Contents for 1-33-249

Page 1: ...NTROL Instructions for Use TZB10 IR850 P 24V Telecentric Lights Luminous colour Infrared 850 nm Instructions for Use TZB10 IR850 P 24V Telecentric Lights Luminous colour Infrared 850 nm 999 995 419 10...

Page 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Page 3: ...der no TZB10 IR850 P 24V 1 33 249 Product Identification Designation Description TZB Telecentric Lights 10 Luminous field diameter in mm IR850 Luminous colour Infrared 850 nm P Power LED 24V 24 V DC o...

Page 4: ...TZB10 IR850 P 24V 4 999 995 419 10 en 1 6 Vision Control GmbH 2021...

Page 5: ...ce Views 15 4 2 Notices on the device 16 5 Technical Data 17 5 1 General Parameters 17 5 2 Electrical Parameters 18 5 3 Photometric Parameters 18 5 4 Conditions for Operation Storage and Transport 19...

Page 6: ...TZB10 IR850 P 24V 6 999 995 419 10 en 1 6 Vision Control GmbH 2021...

Page 7: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potent...

Page 8: ...ns of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1...

Page 9: ...al and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maint...

Page 10: ...s of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium...

Page 11: ...ce and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric sh...

Page 12: ...holder Designation Description Order no Lens Holder d35 5 Holder for telecentric lenses and lightings with 35 5 mm clamping diameter for vibration free attachment 2 90 124 Polarizing filter Filter ada...

Page 13: ...4 pin straight plug 4A 60V Designation Description Order no Cable M8 4p 4A straight 10m Connection cable with 4 pin M8 socket and open cable end with wire end ferrules 4 x 0 25 mm 4A 60V PUR IP67 str...

Page 14: ...onnection cable with 4 pin M8 socket and open cable end with wire end ferrules 4 x 0 5 mm 5A 30V PUR IP67 straight plug 1 11 614 Extension cable M8 4 pin 5A 30V Designation Description Order no Extens...

Page 15: ...CRIPTION 4 1 Device Views 6 2 3 5 5 5 4 1 Image 1 Device view 1 Casing 2 Light emitting surface 3 Identification plate 4 Note screw in depth 5 Mounting surface with mounting holes 6 Connector M8 4pin...

Page 16: ...g instructions are provided on the device Type plate Type TZB10 XXXX P 24V SN XXXXXXXX 1 2 Image 2 Type plate 1 Device designation 2 Serial number Notice Screw in depth screw in depth max 7mm Image 3...

Page 17: ...ght emitting surface Diameter 11 5 mm Connector Male connector M8 4 pin Weight 96 g Degree of protection IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Risk group 0...

Page 18: ...input ON OFF Input delay tD 50 s 100 s 150 s 5 3 Photometric Parameters Parameter Min Nom Max Peak wavelength peak 860 nm Centroid Wavelength centroid 850 nm Spectral bandwidth 30 nm Full divergence...

Page 19: ...rve the specified ambient conditions when transporting and storing the device For accessories connected devices and components observe the specific information in the associated instructions for use A...

Page 20: ...tra e 16 98527 Suhl 1 2 3 4 5 1 2 3 4 5 A A B B C C D D M8 connector TZB10 XXXX P 24V TZB10 XXXX HP 24V l i g h t e m i t t i n g s u r f a c e 1 1 5 3 5 5 2 x M4 depth 6 15 6 15 23 10 58 13 23 33 7 I...

Page 21: ...the tucked in sides on the bottom of the cardboard The film loosens and forms an insertion pocket 3 Remove the device out of the insertion pocket 4 Dispose the packing material 6 2 Mounting the Devic...

Page 22: ...3 Tighten the M5 hexagon nuts alternately hand tight in small steps Mount the Filter adapter slip on adapter 1 2 3 a a a 1 Loosen the M3 threaded pins a of the slip on adapter 2 Attach the slip on ada...

Page 23: ...a a b 1 Loosen the M3 threaded pins a of the deflection mirror 2 Attach the deflection mirror on the lighting Rotate the mirror b to the desired position 3 Tighten the M3 thread pins alternately hand...

Page 24: ...cification see data sheet 6 4 1 Pin assignment Use the M8 connector to connect the device according to the pin assignment Pin assignment 1 2 3 4 Image 7 M8 connector 4 pin Connection diagram V GND 1 3...

Page 25: ...ere there are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event o...

Page 26: ...ing the switching signal ON OFF Consider the switching delay time td of the lighting Set the exposure time of the camera to be within the tON range The length of the Power on time tON corresponds to t...

Page 27: ...leaning the optical surfaces NOTICE Follow the specified cleaning sequence Never use dry cloths for cleaning This allows dust and other contaminants to be rubbed into the lens surface thereby damaging...

Page 28: ...lad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device...

Page 29: ...eparately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done...

Page 30: ...TZB10 IR850 P 24V 30 999 995 419 10 en 1 6 Vision Control GmbH 2021...

Page 31: ...al environments DIN EN IEC 61000 6 4 2020 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and meas...

Page 32: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...