Dosing system eco-CONTROL EC200-K
Operation and maintenance instructions
Version 1.8
Copyright ©
5.9.9
Time and date
• Press the
PRG
key,
system selection menu
,
display 2 appears.
• Select
Administration
, display 25 appears.
Display 2
• Select
Set time
, the time and the date can be set in
the status bar with the aid of the
NAVI wheel
field by field.
Display 25
5.9.10 System and error messages
Switching error messages on / off
• Press the
PRG
key,
the start screen
, display 1
appears.
Display 1
• Press and hold down the
START
key.
• Press the
Quantity program
key,
Config.
Error messages
are displayed (display 33).
Select the desired error message and switch it on or off
with the
Enter
key
Press the
Esc
key to quit the menu.
Displa
y 33
If the
Level monitoring
function has been activated with
ON
, the
Ext. level sensor
switch
can be used to switch between the signal input at the plug
sensor
(17) =
OFF and
system plug (19) =
ON
.
The volume is set with the
NAVI wheel
and confirmed with the
Enter
key.
All the values that are set here are saved permanently in the Dosing system.
Note:
The overcurrent monitoring is set permanently to ON.
The primary pressure and level monitoring functions protect the dispenser. This
effectively prevents any damage due to running dry if there is too little medium.
(Connection for the level signal, see 5.2, Connections, page 11)
Start/stop
Time program
Calibration auto
Calibration manuel
Teach in function
Administration
Quantity program
10 47h
Fr 18.03.11
Service
Esc OK
Change program
Tolerance of pressure
Password protection
Analog input
Adjust time
Select program
10 47h
Fr 18.03.11
Dosing system
eco-CONTROL Ec200
Config. alarm messages
Level control
Primary pr. control
Over-current control
External level sensor
Volume OK
10 47h
Fr 18.03.11
Off
Off
On
Off
30
Volume alarm
30