Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Copyright ©
Version 1.4
5.4
Functional and operational schematic
The interaction of the screen displays, the input dialog and the function keys:
The control system has an intuitive input dialog. The
selection or the change of a value is offered on the screen to
suit the relevant program section. The corresponding area
(A) on the screen is then shown as inverse or framed.
The status bar (B) provides plain text messages in
accordance with the input dialogs.
NAVI wheel
(See 5.1, Displays and controls, page 10)
Enables rapid selection, input and confirmation of different functions.
The
rotation
of the
NAVI wheel
switches
to the next or previous selection, depending on
the direction of rotation, or changes a value.
A
press
of the
NAVI wheel
confirms
a selection or a change in value that had just been
made. (Alternatively, the
Return
key can also be used for confirmation)
The illumination of the
NAVI-wheel
signalises the following operating states: Blue =
Ready for operation, Green = Dosing in progress, Red = Fault.
Changing a setting value
1. Select the value to be changed by
rotating the NAVI wheel
, the value is shown in
inverse.
2.
Press the NAVI wheel
, numbered items can be selected individually.
3. Select a numbered item
by
rotating the NAVI wheel
, the numbered item flashes.
4.
Press the NAVI wheel
, the numbered item is shown in inverse.
5. Change the value by
rotating
the
NAVI wheel
and press the
NAVI wheel
for
confirmation, the numbered item flashes again. Another numbered item can be
selected.
6. If further numbered items are to be changed, start again from 3., and if not, continue.
7. Press the
PRG
key to confirm the change, the value that has just been set is shown
in inverse, if other values can be changed in the input dialog, these can now be
reached by
rotating
the
NAVI wheel
.
Esc
Used to quit an input dialog. In some cases it also assumes other functions. If that is the
case, this is shown in plain text in the status line.
Press Start
Esc
Calibration auto
Motor A
ml
Desired qty
Actual qty
ml
ml
00.500ml
00.000ml
A
B
00.500