34 / 35
Version 1.9
Copyright ©
eco-CONTROL EC200-B
Operation and maintenance instructions
8
Technical data
8.1
Dosing control
8.2
Dispenser
See the commissioning and maintenance manual supplied with the dispenser.
8.3
Interfaces
Please request manufacturer or your distributor.
9
Disposal
Dimensions (HxWxD)
92.5 x 240 x 197 mm
Cutout dimensions control cabinet
(HxW)
85 x 191 mm
Weight
approx. 980 g
Voltage / mains adapter
24 V DC / option
Performance
max. 50 W
depending on the output set
Start
Key, foot switch
Start / stop externally
24 V pulse, 10 mA terminal strip; low 0 to 1.5 V,
high 12 to 24 V
On / off switch
no
Interface
RS 232
Compressed air monitoring
0 to 7 bar (0 to 100 psi)
External memory
MM C/SD-Card min 64 MB
max. 24 dosing programs
can be read with a Microsoft operating system
Operating conditions
+10 °C to +40 °C (non-condensing),
air pressure 1 bar
Medium temperature
+10°C to +40°C
Storage conditions
dry/dust-free -10 to +40°C
The final disposal of the Dosing system is to be done in an environmentally-
appropriate way. All the materials and packaging must be handled in accordance
with the recycling stipulations.
Do not dispose of electrical parts in the household garbage.
They are to be taken to the appropriate collecting points.
2002/96/EU(WEEE)* EU DIRECTIVE concerning used electrical and electronic
equipment.
This equipment complies with the RoHS stipulations.