ViSAGE MD 13400 Instruction Manual Download Page 1

Model Number MD 13400

Wrist Type

Blood Pressure Monitor

INSTRUCTION MANUAL

Email:

 [email protected]

Telephone:             

1300 884 987

09/2012

MEDION Australia Pty Ltd

St Leonards, NSW 2065

Australia

helpline: 1300 884 987

Email: [email protected]

www.medion.com.au

Wrist Type

C

M

Y

CM

MY

CY

CMY

K

13400 EN Aldi AUS RC3 Cover.ai   1   23.05.2012   10:28:59

13400 EN Aldi AUS RC3 Cover.ai   1   23.05.2012   10:28:59

Summary of Contents for MD 13400

Page 1: ...Model Number MD 13400 Wrist Type Blood Pressure Monitor INSTRUCTION MANUAL Email australia medion com Telephone 1300 884 987 Wrist Type ...

Page 2: ... Section 07 Symbols and key words used in these instructions 09 Information and Safety Instructions 14 Scope of Delivery 15 Getting Started 26 Features 30 Instructions 47 Other Useful Information N Aldi AUS Final Content indd 03 N Aldi AUS Final Content indd 03 26 06 2012 09 5 26 06 2012 09 5 ...

Page 3: ...in this warranty period under normal use and care will be repaired replaced or refunded at our discretion solely at our option with no charge for parts and labour The benefits conferred by this warranty are in addition to all rights and remedies in respect of the product that the consumer has under the Competition and Consumer Act 2010 and similar state and territory laws N Aldi AUS Final Content i...

Page 4: ...ed to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure N Aldi AUS Final Content indd 05 N Aldi AUS Final Content indd 05 26 06 2012 09 5 26 06 2012 09 5 ...

Page 5: ...to you by Visage are manufactured to the highest standards of performance and safety and as part of our philosophy of customer service and satisfaction are backed by our comprehensive 1 Year Warranty We hope you will enjoy using your purchase for many years to come N Aldi AUS Final Content indd 06 N Aldi AUS Final Content indd 06 26 06 2012 09 5 26 06 2012 09 5 ...

Page 6: ...s CAUTION Please note the following guidelines to avoid minor or moderate injuries and property damage ATTENTION Please note the following guidelines to avoid property damage NOTICE Additional information on using the device N Aldi AUS Final Content indd 07 N Aldi AUS Final Content indd 07 26 06 2012 09 5 26 06 2012 09 5 ...

Page 7: ...il australia medion com NOTICE Observe the notes in the instruction manual Bulleted item information on operating steps and results Tasks to be performed N Aldi AUS Final Content indd 08 N Aldi AUS Final Content indd 08 26 06 2012 09 5 26 06 2012 09 5 ...

Page 8: ...ithout experience and or knowledge unless they are supervised by a person responsible for their safety or they have been instructed in its use Children should be supervised to ensure they do not play with this device Keep plastic packaging out of the reach of children There is a risk of suffocation The device is suitable for healthy adults Use the N Aldi AUS Final Content indd 09 N Aldi AUS Final ...

Page 9: ...cessories out of reach of children Do not start the air supply with the button until the device is attached correctly to the arm Do not drop the device and do not place objects on top of it Never immerse the device in water Do not expose it to water or moisture Do not use the device under extreme temperature conditions Do not bend the fixed part of the sleeve N Aldi AUS Final Content indd 10 N Ald...

Page 10: ...y important that you follow the instructions below Keep batteries away from children If batteries are mistakenly swallowed consult your doctor immediately Before inserting the batteries check that the contacts in the device and on the batteries are clean and if necessary clean them Never charge batteries unless it is expressly specified Risk of explosion Never short circuit the batteries N Aldi AU...

Page 11: ...iately Never expose the batteries to excessive heat such as direct sunlight fire or similar Always observe the correct polarity Make sure that the plus and minus poles are correctly inserted to avoid short circuits Remove spent batteries from the device immediately Remove the batteries from the device if you do not intend to use it for an extended period Replace all of the old batteries in a devic...

Page 12: ...tre if you have technical problems with your device Never try to open or repair the device yourself If there is a fault contact the Medion Service Centre or another suitable specialist workshop in order to avoid any risks N Aldi AUS Final Content indd 13 N Aldi AUS Final Content indd 13 26 06 2012 09 5 26 06 2012 09 5 ...

Page 13: ...check that the contents are complete and notify us within 14 days of purchase if any of the following components are missing 1 device 1 bag 2 1 5 V batteries AAA Instruction manual and warranty document N Aldi AUS Final Content indd 14 N Aldi AUS Final Content indd 14 26 06 2012 09 5 26 06 2012 09 5 ...

Page 14: ... high This blood pressure monitor helps you to take regular comparative measurements Proper use The device is used to measure blood pressure at the wrist and can save 60 measurement values in each of two memory spaces It is suitable for healthy people and can be used to make comparative measurements especially during sporting activities N Aldi AUS Final Content indd 15 N Aldi AUS Final Content ind...

Page 15: ...sing the device under extreme environmental conditions may result in damage to the device What is blood pressure Blood pressure is a measurement of the force that the heart has to exert to pump the blood through the circulatory system and vital organs in the body The higher the pressure the harder the heart has to work N Aldi AUS Final Content indd 16 N Aldi AUS Final Content indd 16 26 06 2012 09...

Page 16: ...he average blood pressure Blood pressure can be higher than usual if parts of the circulatory system are restricted diseased or abnormal in other ways High blood pressure can cause damage to vital organs including the brain and heart Measuring range The blood pressure monitor shows you the blood pressure SYS systolic and DIA diastolic value pulse and the time and date on the display Blood pressure...

Page 17: ...ion from 1999 The WHO defines high blood pressure as values above 140 mmHg systolic value and 90 mmHg diastolic value Your blood pressure monitor is fitted with a colour indicator that makes it easier to assess the measured values The following summary can help you to assess the values you measure N Aldi AUS Final Content indd 18 N Aldi AUS Final Content indd 18 26 06 2012 09 5 26 06 2012 09 5 ...

Page 18: ...ralia medion com Blood pressure classification according to WHO in mmHg mmHg 140 130 85 90 SYS DIA 1 2 3 1 Normal range 2 Borderline 3 High blood pressure range N Aldi AUS Final Content indd 19 N Aldi AUS Final Content indd 19 26 06 2012 09 5 26 06 2012 09 5 ...

Page 19: ... blood pressure 90 50 Green Normal blood pressure 91 129 51 84 Green Borderline 130 139 85 89 Green High blood pressure I 140 159 90 99 Yellow High blood pressure II 160 179 100 109 Orange High blood pressure III 180 110 Red N Aldi AUS Final Content indd 20 N Aldi AUS Final Content indd 20 26 06 2012 09 5 26 06 2012 09 5 ...

Page 20: ...that no more blood can flow through them If the pressure in the sleeve is then reduced this creates a relationship between the sleeve pressure and the blood pressure The device has electronic step valves that can detect even slight changes during the measurement which can be evened out using the sleeve pressure By reducing the pressure step by step fluctuations in the sleeve are recorded by the devi...

Page 21: ...hange your treatment dosage of medication as a result of the values unless you have discussed this with your doctor By using your device you can get a clear overview of your blood pressure by measuring it regularly and using clear records Everybody s blood pressure changes constantly Fluctuations may be caused by mental and physical factors such as fear exertion smoking caffeine and N Aldi AUS Fin...

Page 22: ...ive a realistic representation of your blood pressure Always measure your blood pressure at the same time of the day Measure your blood pressure when you are relaxed Try to rest for fifteen minutes before measuring your blood pressure You should wait an hour after a large meal before measuring your blood pressure Do not smoke or drink alcohol before measuring your blood pressure Do not undertake a...

Page 23: ...5 minutes if you want to measure your blood pressure again Please ensure that you always measure your blood pressure under the same conditions Also note the information about maintaining the correct posture during measurement on page 36 Different measurement conditions can lead to different measurement factors and therefore to markedly different values N Aldi AUS Final Content indd 24 N Aldi AUS F...

Page 24: ... differs greatly from your normal blood pressure measurement you should carry out a new measurement after a short period of time in order to exclude the factors listed above that can lead to an incorrect measurement N Aldi AUS Final Content indd 25 N Aldi AUS Final Content indd 25 26 06 2012 09 5 26 06 2012 09 5 ...

Page 25: ...ales Support Telephone 1300 884 987 Email australia medion com Features Overview of the equipment 5 6 7 8 1 2 3 4 N Aldi AUS Final Content indd 26 N Aldi AUS Final Content indd 26 26 06 2012 09 5 26 06 2012 09 5 ...

Page 26: ...Email australia medion com 1 User button 2 Clock button 3 ON OFF button 4 Sleeve 5 Battery compartment 6 Save button 7 WHO colour indicator 8 Display N Aldi AUS Final Content indd 27 N Aldi AUS Final Content indd 27 26 06 2012 09 5 26 06 2012 09 5 ...

Page 27: ...fter Sales Support Telephone 1300 884 987 Email australia medion com Display kPa 10 12 11 8 9 1 5 4 6 7 2 3 N Aldi AUS Final Content indd 28 N Aldi AUS Final Content indd 28 26 06 2012 09 5 26 06 2012 09 5 ...

Page 28: ...ored values 4 Unit display 5 Systolic blood pressure value 6 Diastolic blood pressure value 7 Pulse measurement 8 Pulse display with arrhythmia detection 9 User selection 10 Display of blood pressure ranges 11 Pump operation display 12 Date and time display N Aldi AUS Final Content indd 29 N Aldi AUS Final Content indd 29 26 06 2012 09 5 26 06 2012 09 5 ...

Page 29: ...tment at the notch in the direction of the arrow Insert two 1 5 V R03 LR03 AAA batteries Pay attention in the process to the polarity information in the battery compartment the negative terminal faces the spring Close the battery compartment again N Aldi AUS Final Content indd 30 N Aldi AUS Final Content indd 30 26 06 2012 09 5 26 06 2012 09 5 ...

Page 30: ...ror message E6 is displayed when the display remains blank after pressing the button ATTENTION Always change both batteries Never use new and old batteries together or different types of batteries NOTE Rechargeable batteries are not suitable for operating this device N Aldi AUS Final Content indd 31 N Aldi AUS Final Content indd 31 26 06 2012 09 5 26 06 2012 09 5 ...

Page 31: ... your selection by pressing the clock button and the display will change to the year Press the M button until the correct year is displayed Confirm your selection with the clock button and the display will change to the month setting Press the M button until the correct month is displayed Confirm your selection with the clock button and the display will change to the day setting N Aldi AUS Final Con...

Page 32: ... is displayed Confirm your selection with the clock button and the display will change to the minute setting Press the M button until the correct time is displayed Confirm your selection with the clock button and now the current time and date will appear on the display Switch off the device by pressing the ON OFF button You can call up the setting mode at any time N Aldi AUS Final Content indd 33 N ...

Page 33: ...om Press the clock button the current time and date will appear on the display Press the clock button and hold it down for 3 seconds The unit reading will flash in the display N Aldi AUS Final Content indd 34 N Aldi AUS Final Content indd 34 26 06 2012 09 5 26 06 2012 09 5 ...

Page 34: ...palm of your hand Wrap the sleeve tightly around your wrist so that there is no gap between the sleeve and your wrist 0 5 1cm Wrap the sleeve according to the shape of your wrist If the sleeve is not firmly attached the pressure will increase and the wrist will become numb Correct measurement is then no longer possible N Aldi AUS Final Content indd 35 N Aldi AUS Final Content indd 35 26 06 2012 09 ...

Page 35: ... instead Correct measurement To measure your blood pressure sit comfortably on a chair take 5 or 6 deep breaths and relax Place your elbow on a table or other supporting surface and hold your arm so that the wrist sleeve is at heart height In doing so support your lower arm on a folded towel or similar N Aldi AUS Final Content indd 36 N Aldi AUS Final Content indd 36 26 06 2012 09 5 26 06 2012 09 ...

Page 36: ...ays measure your blood pressure at the same time each day It is important to measure your blood pressure at home and at the same time each day so that the blood pressure which can change over the course of a day is recorded properly Inform your doctor of the values measured so that you N Aldi AUS Final Content indd 37 N Aldi AUS Final Content indd 37 26 06 2012 09 5 26 06 2012 09 5 ...

Page 37: ...d the strength of the blood vessels in the wrist and upper arm In many cases the difference for healthy people can be 10 mmHg of the systolic and diastolic blood pressure CAUTION Attention is advised for the following types of person People with high blood pressure diabetes liver disease hardened arteries or poor circulation In these cases consult your doctor before using this device to monitor yo...

Page 38: ...nking ventilation symbol and the selected user are shown on the display Do not move the sleeve your arm or hand muscles during measurement After a few seconds the device will pump up the sleeve When the sleeve pressure is stable the device will start measuring automatically If you want to stop the measurement press the ON OFF button The sleeve deflates N Aldi AUS Final Content indd 39 N Aldi AUS Fi...

Page 39: ...t sleeve pressure is reached for the measurement Measurement starts when the correct sleeve pressure has been reached The device also measures your pulse The value displayed will fall during measurement The sleeve deflates when the measurement is complete The systolic and diastolic blood pressure as well as the pulse and the pulse symbol appear on the display The data is automatically saved to the ...

Page 40: ...s case repeat the measurement Abnormal pulse rhythms can have different causes If the pulse is constantly arrhythmic please consult your doctor User settings The blood pressure monitor has two memory spaces which allow two different users to save up to 60 measurements each The device calculates the average value from the last three measurements N Aldi AUS Final Content indd 41 N Aldi AUS Final Con...

Page 41: ...cted user will be shown on the display If necessary press the user button again to switch between the two memory spaces Press the ON OFF button to switch off the device NOTE Please be aware that when there are two users that the currently selected user will remain active until a new user has been selected N Aldi AUS Final Content indd 42 N Aldi AUS Final Content indd 42 26 06 2012 09 5 26 06 2012 ...

Page 42: ...wn on the display This is indicated on the display with AVG Press the M button again in order to display the results of the last measurement Press the ON OFF button to switch off the device Deleting memory values You can delete individually saved measurements or all of the measurements for each user Press the ON OFF button to switch on the device N Aldi AUS Final Content indd 43 N Aldi AUS Final C...

Page 43: ...nt will be shown on the display Select the value to be deleted with the M button Press and hold down the M button for approx 3 seconds CL and two lines will be shown on the display Press the user button CL and 00 will be shown on the display The value has now been deleted N Aldi AUS Final Content indd 44 N Aldi AUS Final Content indd 44 26 06 2012 09 5 26 06 2012 09 5 ...

Page 44: ...cted user repeate the first three steps until the average measurement is shown on the display This is indicated on the display by AVG Press and hold down the M button for approx 3 seconds CL and two lines will be shown on the display N Aldi AUS Final Content indd 45 N Aldi AUS Final Content indd 45 26 06 2012 09 5 26 06 2012 09 5 ...

Page 45: ...il australia medion com Press the user button CL and 00 will be shown on the display All of the saved values for the selected user have now been deleted N Aldi AUS Final Content indd 46 N Aldi AUS Final Content indd 46 26 06 2012 09 5 26 06 2012 09 5 ...

Page 46: ...hold campaign days for checking blood pressure monitors Cleaning storage Only use a dry soft cloth to clean the device Do not use chemical solutions and cleaning products because these may damage the device s surface and or inscriptions Store and transport the device in the storage bag supplied Do not bend the preshaped sleeve outwards The N Aldi AUS Final Content indd 47 N Aldi AUS Final Content ...

Page 47: ...ng Your device has been packaged to protect it from damage in transit The packaging is made of environmentally friendly material which can be recycled Device At the end of its service life the device should not be disposed of with the household rubbish Please enquire about the options for environmentally friendly disposal N Aldi AUS Final Content indd 48 N Aldi AUS Final Content indd 48 26 06 2012...

Page 48: ...l australia medion com Batteries Do not dispose off used batteries in the household rubbish They should be taken to a collection point for used batteries N Aldi AUS Final Content indd 49 N Aldi AUS Final Content indd 49 26 06 2012 09 5 26 06 2012 09 5 ...

Page 49: ...or Possible causes solutions Display is blank The batteries are dead Replace both batteries with new 1 5 V R03 LR03 AAA batteries E 1 The sleeve is not fitted correctly Check the fitting of the sleeve and carry out a new measurement E 2 You moved while you were measuring your blood pressure Sit still and carry out a new measurement N Aldi AUS Final Content indd 50 N Aldi AUS Final Content indd 50 26...

Page 50: ...y out a new measurement E 4 An error has occurred in the measurement Carry out a new measurement E 5 Sleeve pressure above 300 mmHg Check the fitting of the sleeve and carry out a new measurement E 6 Batteries are too weak Replace both batteries with new 1 5 V R03 LR03 AAA batteries N Aldi AUS Final Content indd 51 N Aldi AUS Final Content indd 51 26 06 2012 09 5 26 06 2012 09 5 ...

Page 51: ...re 30 250 mmHg Pulse 40 180 beats min Power supply 2 x 1 5 V batteries R03 LR03 AAA Display LCD Memory spaces 2 x 60 measurement results Pressure build up Pressure built up automatically by pump Air release Air released automatically via a one way valve N Aldi AUS Final Content indd 52 N Aldi AUS Final Content indd 52 26 06 2012 09 5 26 06 2012 09 5 ...

Page 52: ...Hg pressure indicator Pulse 5 of value displayed Temperatures Operating temperature 10 40 C at humidity 30 85 Storage temperature 20 60 C at humidity 10 95 Sleeve size 13 5 19 5cm Subject to technical modifications N Aldi AUS Final Content indd 53 N Aldi AUS Final Content indd 53 26 06 2012 09 5 26 06 2012 09 5 ...

Page 53: ... 2009 and EN 1060 3 1997 A2 2009 The device meets the requirements of electromagnetic compatibility EN 60601 1 2 2007 If you have questions about electromagnetic compatibility or the values measured or would like to view the full declarations of conformity please contact our customer service department The helpline number is shown in the footer of this page N Aldi AUS Final Content indd 54 N Aldi ...

Page 54: ... against electric shock Year of manufacture 2012 Manufacturer in accordance with guidelines for medical products Grandway Technology Limited 518118 Shenzhen P R China The serial number of the device can be found in the battery compartment N Aldi AUS Final Content indd 55 N Aldi AUS Final Content indd 55 26 06 2012 09 5 26 06 2012 09 5 ...

Page 55: ...4 987 Operating Hours Monday to Friday 8 30 AM to 6 00 PM EST MEDION Australia Pty Ltd St Leonards NSW 2065 Australia Always remember to provide or state the following Date of purchase invoice proof of purchase Type of fault fault description Status 02 14 2012 N Aldi AUS Final Content indd 56 N Aldi AUS Final Content indd 56 26 06 2012 09 5 26 06 2012 09 5 ...

Page 56: ...stralia Pty Ltd St Leonards NSW 2065 Australia helpline 1300 884 987 Email australia medion com www medion com au 13400 EN Aldi AUS RC3 Cover ai 1 23 05 2012 10 28 59 13400 EN Aldi AUS RC3 Cover ai 1 23 05 2012 10 28 59 ...