background image

Models:

VT1, VT1/2, VT1/2A, VT1/2B, VT1/12
VT4, VT4/2, VT4/2A, VT4/2B, VT4/12

Owner’s Manual

Powered by

520074_RevL

®

2

450 Business Park Dr.,

 Vista, CA 92081

  

 

(760) 727-3711

    

 

(760) 727-4427   

 

www.appliedmembranes.com  

 

 

[email protected]

Industry Leader in RO Expertise and Membrane Applications since 1983™

Distributed By:

Summary of Contents for Sterilight VT1/12

Page 1: ...A VT4 2B VT4 12 Owner s Manual Powered by 520074_RevL 2450 Business Park Dr Vista CA 92081 760 727 3711 760 727 4427 www appliedmembranes com sales appliedmembranes com Industry Leader in RO Expertise...

Page 2: ...y should you insist on genuine factory supplied VIQUA replacement lamps Use of widely available non genuine replacement lamps has been shown to damage the control module of VIQUA UV disinfection equip...

Page 3: ...started Warning This product may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm DANGER Failure to follow these instructions will resul...

Page 4: ...o clean up a broken lamp as this may scatter the spilled mercury Obey local regulations and guidelines for the removal and disposal of mercury waste NOTICE The UV lamp inside the disinfection system i...

Page 5: ...mps for long consistent life 9000 hours S212RL VT1 VT1 2 VT1 2A VT1 2B VT1 12 VT1 12 MEX S330RL VT4 VT4 2 VT4 2A VT4 2B VT4 12 VT4 12 MEX 4 Retaining nut RN 001 Used on all systems 5 Lamp connector 6...

Page 6: ...e used for the installation The use of a by pass assembly is recommended in case the system requires off line maintenance In this case note the system requires a supplementary disinfection for the dis...

Page 7: ...chamber making sure the connection end is inserted last Mount the disinfection system to the wall with the supplied clamp 6 When all plumbing connections are complete slowly turn on the water supply...

Page 8: ...Do not consume water until complete system has been flushed 1 Ensure the controller is plugged in for entire disinfection process 2 2 1 2 2 2 Shut off the water supply Close each faucet 3 Press the pr...

Page 9: ...NOTICE Refer to www lamprecycle org for UV lamp disposal Do not use water during replacement of UV lamp 1 Shut off the water line to UV chamber and release system pressure before servicing 2 0 30 15...

Page 10: ...ater 1 Drain the UV chamber by using the drain port 2 1 2 3 Remove the bottom retaining nut floating spring and O ring 3 1 2 Remove the top retaining nut and O ring 4 Carefully remove O ring adhering...

Page 11: ...8 kg 4 lbs 2 9 kg 6 5 lbs 2 9 kg 6 5 lbs Electrical Voltage 100 140 V 50 60 Hz 12 VDC 200 240 V 50 60 Hz 100 140 V 50 60 Hz 12 VDC 200 240 V 50 60 Hz Max Current 0 28 Amp 1 8 Amp 0 16 Amp 0 28 Amp 1 8...

Page 12: ...Hardware Components VIQUA warrants the electrical controller and hardware components to be free from defects in material and workmanship for a period of three 3 years from the date of purchase During...

Page 13: ...2450 Business Park Dr Vista CA 92081 760 727 3711 760 727 4427 www appliedmembranes com sales appliedmembranes com Industry Leader in RO Expertise and Membrane Applications since 1983 Distributed By...

Reviews: