3.2 Displays and Instructions

3.2.1 General Operation

When the system is operating, one of four following displays may be shown. Pressing 

NEXT

 will toggle between the 

displays.

If the system has called for a regeneration that will occur at the preset time of regeneration, the words “

REGEN TODAY

” 

will appear on the display.

If a water meter is installed, “

GPM

” flashes on the display when water is being treated, indicating gallons per minute 

going through the system.

3.2.2 Regeneration Mode

Typically a system is set to regenerate at a time of no water usage. If there is a demand for water when the system is 

regenerating, untreated water will be delivered. When the system begins to regenerate, the display will change to include 

information about the step of the regeneration process and the time remaining for that step to be completed. The system 

runs through the steps automatically and will reset itself to provide treated water when the regeneration has been 

completed.

4

•   

Regeneration hours: Press 

NEXT

 or press 

REGEN

 to 

return to the previous step.

Note: 

The manufacturer has factory set 2:00 A.M. as 

the default. This is the hour of day for regeneration and 
can be reset by using 

+

 or 

 buttons. “AM/PM” toggles 

after 12. The default time is 2:00 A.M. (recommended 
for a normal household).

5

•   

Set the regeneration minutes using + or – buttons. 

•   

Press 

NEXT

•   

Press 

REGEN

 to return to previous step. 

•   

To initiate an immediate manual regeneration, press and 

hold the 

REGEN

 button for three seconds. The system will 

begin to regenerate immediately. The control may be 
manually stepped through the re generation cycles by 
pressing 

REGEN

.

6

•   

Turn the alarm OFF or ON using 

+

 or 

-

 buttons. 

•   

Press 

NEXT

 to exit installer programming. 

Note: 

The manufacturer has factory set ON as the 

default. Alarm will sound immediately after regeneration if 
there is no salt or if another error has occurred.

Current “TIME OF DAY” and “GPM” 

FLOW RATE

 is the current treated 

water flow rate through the system 

measured in GPM.

CAPACITY REMAINING

 is the 

gallons that will be treated before the 

system signals a regeneration cycle.

DAYS TO A REGEN

 is the number 

of days left before the system goes 

through a regeneration cycle, based 

on the days override value.

Summary of Contents for AWP-SE1 series

Page 1: ...Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com Models AWP SE1 and AWP SE2 Series Water Condition...

Page 2: ...en installed and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any questions...

Page 3: ...e has completed the immediate regeneration the valve will regenerate one more time at the preset 1 2 Bypass Valve The bypass valve is typically used to isolate the control valve from the plumbing syst...

Page 4: ...ndle points away from the control valve The water is shut off to the building The water treatment system will depressurize upon opening a tap in the building A negative pressure in the building combin...

Page 5: ...before servicing Changes or modifications made to this system without the consent of the manufacturer could render the system unsafe for operation and may void the manufacturer s warranty The control...

Page 6: ...drain empties into an overhead sewer line a sink type trap must be used Run drain tube to its discharge point in accordance with plumbing codes Pay special attention to codes for air gaps and anti sip...

Page 7: ...he day of the week using or buttons If it is desired to back up to the previous step press REGEN button once Pressing NEXT will exit SET CLOCK and return to the general operating display 1 Press NEXT...

Page 8: ...Press NEXT or press REGEN to return to the previous step Note The manufacturer has factory set 2 00 A M as the default This is the hour of day for regeneration and can be reset by using or buttons AM...

Page 9: ...will keep time of day until the battery is depleted When the battery becomes depleted the only item that needs to be reset is the time of day and will be indicated by the time of day flashing All oth...

Page 10: ...ervice softening The system is now ready for filling with water and for testing 1 With the softener in the bypass mode Figure 2 and the control valve in normal operation where the display shows either...

Page 11: ...REGEN until the display reads FILL and then press REGEN again to return to the normal service position with TIME OF DAY being displayed 3 3 2 Water Conditioner Flow Diagrams C A U T I O N If water flo...

Page 12: ...rty Clean or replace chlorine generator System drawing in air Tighten fittings in brine system System short brining Clean brine line flow control check for bridging or hardened salt around brine well...

Page 13: ...Defective meter Replace meter Programming error Review programming Defective PC board Replace board ERROR followed by code ERROR code 1001 unable to recognize start of regeneration ERROR code 1002 une...

Page 14: ...umber Quantity 1 Black cover CV3540S A 1 Grey cover CV3540 WS A 1 2 Motor CV3107 1 1 3 Drive bracket spring clip CV3106 1 1 4 PC board CC CV3554WS 1 5 Drive gear 12 x 36 CV3110 3 6 Drive gear cover CV...

Page 15: ...ston assembly down flow CV3407 1 5 Regenerant piston CV3174 1 6 O ring 337 CV3180 1 7 O ring 215 CV3105 1 8 Screw 1 4 20x1 1 2 18 8SS CV3556 1 9 Nut 1 4 20 HEX 18 8SS CC1 00318337 1 10 QC2 clamp assem...

Page 16: ...1 quick connect CV3151 2 2 Split ring CV3150 2 3 O ring 215 CV3105 2 4 Bypass rotor 1 CV3145 2 5 Bypass cap CV3146 2 6 Bypass handle CV3147 2 7 Bypass rotor seal retainer CV3148 2 8 O ring 135 CV3152...

Page 17: ...sembly BLACK CV3010 1A 1 B injector assembly BROWN CV3010 1B C injector assembly VIOLET CV3010 1C D injector assembly RED CV3010 1D E injector assembly WHITE CV3010 1E F injector assembly BLUE CV3010...

Page 18: ...ement Parts 18 5 5 Chlorine Generator Assembly Item Description Part Number Quantity 1 Chlorinator CV3395 1 2 O ring 019 CV3163 1 3 Locking clip CH4615 1 4 Refill port plug assembly CV3195 01 1 6 4 3...

Page 19: ...1 7 0 7 DLFC for 3 4 elbow CV3162 007 1 1 0 DLFC for 3 4 elbow CV3162 010 1 3 DLFC for 3 4 elbow CV3162 013 1 7 DLFC for 3 4 elbow CV3162 017 2 2 DLFC for 3 4 elbow CV3162 022 2 7 DLFC for 3 4 elbow...

Page 20: ...r Plug Item Description Part Number Quantity 1 Nut 1 QC CV3151 1 2 Meter assembly includes items 3 and 4 CV3003 1 3 Turbine assembly CV3118 01 1 4 O ring 215 CV3105 1 5 Meter plug assembly CV3003 01 1...

Page 21: ...ow set CH1018 1 3 474 air check assembly 1 2 x 48 CH4500 48 1 4 474 float assembly 32 with two grommets CH4640 32 1 5 474 safety brine valve with 0 5 gpm flow control CH4600 50 1 6 Cap 4 brine well CH...

Page 22: ...ssembly Item Description Part Number Quantity 1 474 0 5 gpm flow control CH4655 1 2 O ring 019 CH3163 1 3 3 8 elbow cap Parker fitting CV4144 1 1 2 elbow cap CH4612 4 Elbow locking clip CH4615 1 5 Saf...

Page 23: ...2 Split ring CV3150 1 2 Split ring CV3150 1 3 O ring 215 CV3105 1 3 O ring 215 CV3105 1 4 Fitting CV3149 1 4 Fitting CV3199 1 Figure 9 1 Brass Sweat Assembly CV3007 02 Figure 10 3 4 Brass Sweat Assem...

Page 24: ...CV3150 1 3 O ring 215 CV3105 1 3 O ring 215 CV3105 1 4 Fitting CV3164 1 4 Fitting CV3317 1 Figure 13 1 and 1 Brass Sweat Assembly CV3007 09 Figure 14 1 and 1 Pvc Solvent Assembly CV3007 07 Item Descri...

Page 25: ...arts 25 5 11 Service Wrench CV3193 01 Although no tools are necessary to assemble or disassemble the valve the Service Wrench shown in various positions on the valve is available to aid in assembly or...

Page 26: ...3 60 gpg 10 0 ppm 7 0 252 64 4 lpm 17 0 gpm 30 3 lpm 8 0 gpm 25 100 psi 0 5 37 7 C 33 100 F 110V 50 60Hz 3 4 brass 25 4 cm x 157 5 cm 10 x 62 45 7 cm x 91 4 cm 18 x 36 63 5 kg 140 lbs 70 7 kg 156 lbs...

Page 27: ...NEXT 4 Adjust minutes with and buttons 5 Press NEXT 6 Adjust current day with and buttons 7 Press NEXT to complete and return to normal operation Error If the display toggles between ERROR and an erro...

Page 28: ...e warranty does not cover change in water test mis application of media use of mineral cleaners in brine tank including salt additives lack of maintenance or any other acts of God VIQUA will not be re...

Page 29: ...425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 tf 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail info viqua com www viqua com...

Reviews: