Operation
8
3.2 Displays and Instructions
3.2.1 General Operation
When the system is operating, one of four following displays may be shown. Pressing
NEXT
will toggle between the
displays.
If the system has called for a regeneration that will occur at the preset time of regeneration, the words “
REGEN TODAY
”
will appear on the display.
If a water meter is installed, “
GPM
” flashes on the display when water is being treated, indicating gallons per minute
going through the system.
3.2.2 Regeneration Mode
Typically a system is set to regenerate at a time of no water usage. If there is a demand for water when the system is
regenerating, untreated water will be delivered. When the system begins to regenerate, the display will change to include
information about the step of the regeneration process and the time remaining for that step to be completed. The system
runs through the steps automatically and will reset itself to provide treated water when the regeneration has been
completed.
4
•
Regeneration hours: Press
NEXT
or press
REGEN
to
return to the previous step.
Note:
The manufacturer has factory set 2:00 A.M. as
the default. This is the hour of day for regeneration and
can be reset by using
+
or
–
buttons. “AM/PM” toggles
after 12. The default time is 2:00 A.M. (recommended
for a normal household).
5
•
Set the regeneration minutes using + or – buttons.
•
Press
NEXT
.
•
Press
REGEN
to return to previous step.
•
To initiate an immediate manual regeneration, press and
hold the
REGEN
button for three seconds. The system will
begin to regenerate immediately. The control may be
manually stepped through the re generation cycles by
pressing
REGEN
.
6
•
Turn the alarm OFF or ON using
+
or
-
buttons.
•
Press
NEXT
to exit installer programming.
Note:
The manufacturer has factory set ON as the
default. Alarm will sound immediately after regeneration if
there is no salt or if another error has occurred.
Current “TIME OF DAY” and “GPM”
FLOW RATE
is the current treated
water flow rate through the system
measured in GPM.
CAPACITY REMAINING
is the
gallons that will be treated before the
system signals a regeneration cycle.
DAYS TO A REGEN
is the number
of days left before the system goes
through a regeneration cycle, based
on the days override value.