(11)
Select wire size, then adjust synergic control knob
to suit work piece.
(6)
Close down the top roller bracket and clip the
pressure arm into place. Apply a medium amount of
pressure to the drive roller.
(9)
Fit the correct size contact tip over the wire and
fasten tightly into the tip holder.
(7)
Remove the gas nozzle and contact tip from the
front end of the MIG torch.
(10)
Fit the gas nozzle to the torch head.
(8)
Press and hold the Torch Trigger to feed the wire
down the torch cable through to the torch head.
10
| VIPER 120 SYNERGIC MIG Welder Manual
GASLESS MIG INSTALLATION