VIPA SLIO FM 050-1BB30 Manual Download Page 36

Chapter 3   Deployment

 

Manual VIPA System SLIO 

3-4 

 

HB300E - FM - RE_050-1BB30 - Rev. 10/30 

In-/Output area 

 

The following in-/output areas are used by the 050-1BB30: 
At CPU, Profibus and ProfiNET the input respectively output area is 
embedded to the corresponding address area. 
IX = Index for access via CANopen with s = subindex, depends on number 
and type of counter  
SX = Subindex for access via EtherCAT 
 

Addr. 

Name 

Bytes  Function 

IX 

SX 

+0 

CV_I 

Counter 0: Counter value  5400h/s 

01h

+4 

CV_II 

Counter 1: Counter value  5401h/s+1 02h

+8 

CSTS_I 

Counter 0: Counter status  5402h/s 

03h

+10 

CSTS_II 

Counter 1: Counter status  5403h/s+1 04h

 
The 

counter value

 always contains the current value of the corresponding 

counter. 
 
 

Bit 

Name 

Function 

0 ... 1 

reserved 

STS_SW-GATE 

Status software gate  
(set when 

SW gate 

is active) 

3 ... 4 

reserved 

STS_GATE 

Status internal gate  
(set when internal gate is active) 

6 - 

reserved 

STS_C_DN 

Status set at counter direction backward  

STS_C_UP 

Status set at counter direction forward 

9 ... 10 

reserved 

11 

STS_OFLW* 

Status is set at overflow 

12 

STS_UFLW* 

Status is set at underflow 

13 

STS_ZP* 

Status is set at zero run 

14 ... 15 

reserved 

The bits remain set until reset with RES_SET (bit 6 

control word

). 

  

Addr. 

Name 

Bytes Function 

IX 

SX 

+0 

CCTRL_I 

Counter 0: Control word  5602h/s 

01h

+2 

CCTRL_II

Counter 1: Control word  5602h/s+1 02h

 

Bit 

Name 

Function 

0 ... 1 

reserved 

SW_GATE_SET  sets the software gate 

3 ... 5 

reserved 

RES_SET 

resets the bits STS_OFLW, STS_UFLW and 
STS_ZP 

edge 0-1

 

7 ... 9 

reserved 

10 

SW_GATE_RESET resets the software gate 

11 ... 15 

reserved 

 

Overview 

Input area 
12byte 

CV_I 
CV_II 
Counter value 

CSTS_I 
CSTS_II 
Counter status 

Output area 
4byte 

CCTRL_I 
CCTRL_II 
Control word  

Summary of Contents for SLIO FM 050-1BB30

Page 1: ...VIPA System SLIO FM 050 1BB30 Manual HB300E_FM RE_050 1BB30 Rev 10 30 July 2010...

Page 2: ...c Compatibility Directive 2006 95 EC Low Voltage Directive Conformity is indicated by the CE marking affixed to the product Conformity Information For more information regarding CE marking and Declara...

Page 3: ...ion for Users 1 2 System conception 1 3 Dimensions 1 6 Installation 1 7 Wiring 1 11 Trouble shooting LEDs 1 14 Installation guidelines 1 15 General data 1 18 Chapter 2 Hardware description 2 1 Propert...

Page 4: ...Contents Manual VIPA System SLIO ii HB300E FM RE_050 1BB30 Rev 10 30...

Page 5: ...of the VIPA System SLIO Here you will find the information required to assemble and wire a controller system consisting of System SLIO components Besides the dimensions the general technical data of...

Page 6: ...lowing guides are available in the manual an overall table of contents at the beginning of the manual an overview of the topics for every chapter The manual is available in printed form on paper in el...

Page 7: ...anual must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before using or commissioning the compone...

Page 8: ...Safety information Manual VIPA System SLIO 4 HB300E FM RE_050 1BB30 Rev 10 30...

Page 9: ...e information required to assemble and wire a controller system consisting of System SLIO components Besides the dimensions the general technical data of System SLIO will be found Topic Page Chapter 1...

Page 10: ...ge components thereby causing the module to become inoperable or unusable Modules that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in...

Page 11: ...y the electronic power supply may be extended with 2A The System SLIO consists of the following components Bus coupler Periphery modules Power modules Accessories With a bus coupler bus interface and...

Page 12: ...nic module which is mounted to the terminal module by a save sliding mechanism With an error the defective module may be exchanged for a functional module with standing installation By an integrated c...

Page 13: ...nderneath the terminal of the terminal module With a flat mounting rail for adaption to a flat mounting rail you may remove the spacer of the shield bus carrier With each bus coupler to protect the ba...

Page 14: ...bly Manual VIPA System SLIO 1 6 HB300E FM RE_050 1BB30 Rev 10 30 Dimensions 104 109 76 5 48 5 104 109 76 5 15 133 12 9 58 62 12 9 Dimensions in mm Dimensions bus coupler Dimensions periphery module Di...

Page 15: ...odule The module is fixed to the mounting rail by pushing downwards the locking lever The modules may either separately be mounted to the mounting rail or as block Here is to be considered that each l...

Page 16: ...with 2A More about this may be found at Wiring Mount the mounting rail Please consider that a clearance from the middle of the mounting rail of at least 80mm above and 60mm below respectively 80mm by...

Page 17: ...ver may now be mounted at the last module The shield bus carrier available as accessory serves to carry the shield bus to connect cable shields The shield bus carrier is mounted underneath the termina...

Page 18: ...ripes at both sides to the mounting rail 1 2 3 4 With mounting respectively de mounting of a module group you also have to remove the electronic module of the just mounted right module After mounting...

Page 19: ...e If one fuse released its electronic module must be exchanged It is recommended to externally protect the power section supply with a fast 10A fuse and the electronic power supply with a fast 4A fuse...

Page 20: ...at the following backplane bus modules may be placed with a sum current of max 2A Afterwards the power module 007 1AB10 is to be placed again 007 1AB00 Sys DC 5V DC 24V 10A 007 1AB00 Sys DC 5V DC 24V...

Page 21: ...shields The shield bus carrier is mounted underneath the terminal of the terminal module With a flat mounting rail for adaption to a flat mounting rail you may remove the spacer of the shield bus carr...

Page 22: ...er module 007 1AB10 More concerning this may be found above at Wiring RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF RUN MF Behavior After PowerON the MF LED of one module respectively...

Page 23: ...rferencing the environment All System SLIO components are developed for the deployment in hard industrial environments and fulfill high demands on the EMC Nevertheless you should project an EMC planni...

Page 24: ...g lines must be laid isolated When transmitting signals with small amplitudes the one sided laying of the isolation may be favorable Lay the line isolation extensively on an isolation protected earth...

Page 25: ...ation one sided Then you only achieve the absorption of the lower frequencies A one sided isolation connection may be convenient if the conduction of a potential compensating line is not possible anal...

Page 26: ...tic Storage transport EN 60068 2 14 25 70 C Operation Horizontal installation EN 61131 2 0 60 C Vertical installation EN 61131 2 0 60 C Air humidity EN 60068 2 30 RH1 without condensation rel humidity...

Page 27: ...on In this chapter the counter module 050 1BB30 of the System SLIO is described Here every information about the hardware components of the module may be found The technical data are at the end of the...

Page 28: ...10 30 Properties 2 counter 32bit AB invertible DC 24V Counting frequency max 400kHz AB 1 2 4 fold evaluation or pulse and direction Input filter configurable Diagnostics function Type Order number De...

Page 29: ...ption RUN green RUN MF MF red Bus communication is OK Module status is OK Bus communication is OK Module status reports an error Bus communication is not possible Module status reports an error Error...

Page 30: ...ctively track A of an encoder for 1 2 or 4 fold evaluation 2 DC 24V O DC 24V for encoder 3 0V O GND 4 A1 I Counter 1 A pulse Pulse input for counter signal respectively track A of an encoder for 1 2 o...

Page 31: ...neously utilizable vertical 4 Input characteristic IEC 61131 type 1 Input data size 12Byte Technical data digital outputs Number of outputs Cable length shielded Cable length unshielded Rated load vol...

Page 32: ...gnostic functions no Diagnostics information read out possible Module state green LED Module error display red LED Channel error display none Isolation Between channels and backplane bus 9 Insulation...

Page 33: ...this chapter the deployment of the System SLIO counter module 050 1BB30 is described Here every information required for the deployment may be found Topic Page Chapter 3 Deployment 3 1 Fast introduct...

Page 34: ...1h s 1 02h 8 CSTS_I 2 Counter 0 Counter status 5402h s 03h 10 CSTS_II 2 Counter 1 Counter status 5403h s 1 04h Output area Addr Name Bytes Function IX SX 0 CCTRL_I 2 Counter 0 Control word 5602h s 01h...

Page 35: ...C0 Input frequency track B 02h 01h 3101h 02h CH2A 1 C1 Input frequency track A 02h 01h 3102h 03h CH3B 1 C1 Input frequency track B 02h 01h 3103h 04h MODE2_I 1 C0 Counter mode 2 00h 80h 3104h 05h MODE...

Page 36: ...SW GATE Status software gate set when SW gate is active 3 4 reserved 5 STS_GATE Status internal gate set when internal gate is active 6 reserved 7 STS_C_DN Status set at counter direction backward 8 S...

Page 37: ...eter may only be transferred at STOP state Byte Function Possible values 0 Input frequency C0 track A 1 Input frequency C0 track B 2 Input frequency C1 track A 3 Input frequency C1 track B 02h 100kHz...

Page 38: ...ce the I gate SW gate influences I gate 0 0 1 1 with edge 0 1 1 Each counter always starts at 0 When the counter counts forward and reaches the upper count limit and another counting pulse in positive...

Page 39: ..._C 1 reserved 00h 04h ERR_D 1 reserved 00h 05h CHTYP 1 Channel type 76h 06h NUMBIT 1 Number diagnostics bits per channel 00h 07h NUMCH 1 Number channels of the module 02h 08h CHERR 1 reserved 00h 09h...

Page 40: ...Chapter 3 Deployment Manual VIPA System SLIO 3 8 HB300E FM RE_050 1BB30 Rev 10 30...

Reviews: