TM | 900-2C5x0 | Manual
HB39 | TM | 900-2C5x0 | GB | 16-03
VIPA Networking Solutions
TM-C Router
Page 1: ...TM 900 2C5x0 Manual HB39 TM 900 2C5x0 GB 16 03 VIPA Networking Solutions TM C Router ...
Page 2: ...900 2C5x0_000_TM C Router 1 GB 2016 VIPA GmbH Ohmstr 4 91074 Herzogenaurach Telephone 49 9132 744 0 Fax 49 9132 744 1864 Email info vipa com Internet www vipa com ...
Page 3: ...ield implementation environmental conditions 11 3 5 Battery 14 4 Hardware description 15 4 1 Mechanical dimensions 15 4 2 Overall description 16 4 3 Radio communication models 20 4 4 LAN Switch Specifications 22 5 TM C IP Address Access to the Web Configuration 23 5 1 Factory Default IP settings 23 5 2 Powering ON 23 5 3 Setting the TM C LAN IP Address 23 5 4 TM C Web Interface 25 6 Troubleshootin...
Page 4: ...ery effort has been made to ensure that the information contained in this document was complete and accurate at the time of publishing Nevertheless the authors retain the right to modify the information This customer document describes all the hardware units and functions known at the present time Descriptions may be included for units which are not present at the customer site The exact scope of ...
Page 5: ...A GmbH Ohmstraße 4 91074 Herzogenaurach Germany Telefax 49 9132 744 1204 EMail documentation vipa de Contact your local VIPA Customer Service Organization representa tive if you encounter problems with the product or have questions regarding the product If you are unable to locate a customer service centre contact VIPA as follows VIPA GmbH Ohmstraße 4 91074 Herzogenaurach Germany Tel 49 9132 744 1...
Page 6: ...n and useful tips 1 3 Safety information The Teleservice module is constructed and produced for n communication and process control n industrial applications n operation within the environmental conditions specified in the technical data n installation into a cubicle DANGER This device is not certified for applications in in explosive environments EX zone The manual must be available to all person...
Page 7: ...ed out when the system has been disconnected from power Installation and hardware modifications only by prop erly trained personnel The national rules and regulations of the respective country must be satisfied installation safety EMC National rules and regulations apply to the disposal of the unit Disposal VIPA Networking Solutions General Safety information HB39 TM 900 2C5x0 GB 16 03 7 ...
Page 8: ...Concept of the VIPA TM C Family The TM C is available in 3 different versions depending on their com munication interface 2 3 Type and Part Numbers Part Number Type Description 900 2C510 TM C VPN Router WAN LAN 900 2C520 TM C VPN Router WIFI WAN LAN Antenna included in delivery 900 2C580 TM C VPN Router 3G WAN LAN Antenna 900 0AB51 optional 900 0AB51 TM Antenna GSM GPRS UMTS VIPA Networking Soluti...
Page 9: ... time clock RTC Backup battery lifetime has 10 years expect ancy Ethernet Interface LAN Ethernet port 10 100 Mbps Digital Input 2 Digital Output 1 Mounting Latch for DIN rail EN50022 compliant 2 5 Typical applications n Remote Access of Ethernet devices using Talk2M connection n Industrial VPN router VIPA Networking Solutions Product Summary Typical applications HB39 TM 900 2C5x0 GB 16 03 9 ...
Page 10: ...8 EC n R TTE Directive 1999 5 EC for versions including RF modems The product conforms to the corresponding R TTE articles RF spectrum efficiency Art 3 2 EMC Art 3 1b Safety Art 3 1a n REACH Directive 2006 121 EC n For TM C 3G only to comply with R TTE directive Antenna must be mounted on a grounded plate RFI suppressors must be mounted on the power supply cable in the following order starting at ...
Page 11: ...ed on a horizontal Omega type DIN rail EN 50022 1 Pull the slide lock located at the bottom of the unit s back side downwards and present the unit in front of the DIN rail 2 Tilt the TM C upwards in order to hang it on the upper edge of the DIN rail by its hook 3 Gently tilt the unit downwards until it finds its original position 4 Pull the slide lock upwards to fix and lock the unit on the DIN ra...
Page 12: ...on of the equipment a free gap of at least 2 cm must be respected in front of all upper lower ventilation open ings of the unit A free gap of at least 1 cm must be respected on each side of the unit VIPA Networking Solutions Safety Environmental Regulatory Information Field implementation environmental conditions HB39 TM 900 2C5x0 GB 16 03 12 ...
Page 13: ...sed for Ethernet and USB connectivity to comply with the EMC requirements USB cable must be n shorter than 3m n USB 2 0 type n Maximum current per contact 0 5A or better n A plug connected to the TM C Cabling rules VIPA Networking Solutions Safety Environmental Regulatory Information Field implementation environmental conditions HB39 TM 900 2C5x0 GB 16 03 13 ...
Page 14: ... FE terminal is available on the main con nector Ä Specification of the External Power Supply on page 20 Connect this terminal directly to allow impedance ground Shielded cables have to be used for Ethernet and USB to comply with the EMC requirements 3 5 Battery The TM C contains a CR2032 battery This battery is used to main tain the real time clock upto date even when the unit is not powered CAUT...
Page 15: ...4 Hardware description 4 1 Mechanical dimensions VIPA Networking Solutions Hardware description Mechanical dimensions HB39 TM 900 2C5x0 GB 16 03 15 ...
Page 16: ...or including power input terminal 1 DO and 2 DI As shown in the picture the female mating connector is labelled with the appropriate symbols Characteristic Value Connector type MINICONNEC MC model Type MC 1 5 9 ST 3 5 Pitch 3 50 mm 9 pin female Front Upper side Main Connector VIPA Networking Solutions Hardware description Overall description HB39 TM 900 2C5x0 GB 16 03 16 ...
Page 17: ... 2 mA 24 VDC When the TM C reboots a short phase of ON state is part of the starting process The digital output is activated by an open drain MOSFET transistor driven by an optocoupler The maximum current flow inside this tran sistor has a value above the one specified in the TM in order to cope with the switching power losses The transistor used is in an open drain type with predrive This means t...
Page 18: ...2 DI2 Not supported T2M DO Can be wired to an external device to propa gate the Talk2M status If the VPN connection is active the DO is set to 1 Digital Input DI1 can be used as a connectivity condition The configuration of this condition has to be done during the Internet Wizard where you define if the digital input is used or not and for which purpose Possible features VIPA Networking Solutions ...
Page 19: ...etected T2M Talk2M Green ON Talk2M VPN connection established Internet Green ON Internet is configured on the VIPA TM C 1 SMA male connector for WiFi antenna 2 Modem status Green ON WiFi connected 3 Reception signal level Red ON Poor signal 4 Reception signal level Red ON Signal is OK 5 Reception signal level Red ON Good signal Status LED panel All version Status LED panel TM C WiFi VIPA Networkin...
Page 20: ...d against polarity inver sion 4 3 Radio communication models CAUTION This device is intended to be used in fixed or mobile appli cations only not for portable applications The antenna used for this transmitter has to be installed in a space pro viding a safe distance of at least 20 cm without encoun tering any person and must not be co located or operating in conjunction with any other antenna or ...
Page 21: ... ID 209 J00061 Item Value s Protocols and Frequencies GSM GPRS EDGE 850 900 1800 1900 MHz UMTS HSUPA 800 850 900 AWS 1700 1900 2100 MHz Class 5 bands GPRS EDGE Class 33 Antenna Connector Type SMA Antenna GSM GPRS UMTS antenna is available from VIPA with 900 0AB51 as reference n The product complies with the R TTE directive the FCC the IC and Japan regulations related to the GSM modems n Absolute m...
Page 22: ...the power on or the reboot request to get the LAN switch to be fully operational When an TM router is configured to operate a certain way it is part of the strategy if no other method worked to reboot itself This is the ultimate TM strategy to try restoring the requested communication channels and be consistent with requested configura tion Used Wireless Frequen cies Boot process VIPA Networking S...
Page 23: ... Address You can easily establish your first communication with your TM C by using our companion tool eBuddy which can be downloaded from http www vipa com en product anr 900 2C5x0 Connect one of the LAN ports by default port No 1 is always a LAN port of your TM C with your PC point to point or through a network where there is no risk that the TM s default IP address 10 0 0 53 would conflict with ...
Page 24: ...and select it The Serial Number of the TM C is on its label Click Next 3 Enter a new LAN IP address and Subnet Mask Click Next VIPA Networking Solutions TM C IP Address Access to the Web Configuration Setting the TM C LAN IP Address HB39 TM 900 2C5x0 GB 16 03 24 ...
Page 25: ... Open your Internet browser and access the TM C internal Web page by entering the LAN IP address in the URL field the default address is http 10 0 0 53 ð You arrive on a loading page 3 If this is the first boot of the TM C or after a level 2 reset you will be asked for a default language VIPA Networking Solutions TM C IP Address Access to the Web Configuration TM C Web Interface HB39 TM 900 2C5x0 ...
Page 26: ...tomatically redirected to the Quick Launch Wizard page 5 You can follow the Quick Start Guide as an aid to configure your TM C Can be downloaded on http www vipa com en product anr 900 2C5x0 6 To reconfigure your TM C you can easily rerun the wizard by clicking on the Settings button on top of the page VIPA Networking Solutions TM C IP Address Access to the Web Configuration TM C Web Interface HB3...
Page 27: ...he unit OFF and ON again 2 Immediately press and maintain the reset button The LED labeled BI1 turns ON 3 Wait approximately 30 seconds until the USR LED flashes RED 1x per second 4 Immediately release the button if you don t you would reach the second level reset phase The LED labeled BI1 turns OFF 5 Wait approximately 30 secs until the reset procedure is com pleted 6 The TM C restarts automatica...
Page 28: ...a problem The pattern will start with 200ms ON opening of the pattern followed by OFF and a certain number of times of a 1 sec ON allowing to identify the nature of the detected problem If you were to be confronted with an error pattern on the USR LED please write down the pattern you observed and contact your distributor 6 5 Reset Impact Matrix Erased or Reset Preserved Impact Reset Level 1 user ...