USER GUIDE
OXYMETER
W W W.VINVENTIONS.COM
Page 1: ...USER GUIDE OXYMETER WWW VINVENTIONS COM ...
Page 2: ...for dissolved Oxygen measurement in a tank by dipping the probe in the wine To reach the equilibrium more fastly gentle agitation of the probe in the liquid can be performed 3 IN LINE MEASUREMENT Thanks to dedicated accessories the Oxymeter can be used to perform in line measurements directly on the pipe during wine transfer These accessories are available in various diameters and types of connect...
Page 3: ... Presens Wireless Studio PWS is is compatible with all smartphones with at least Android 6 0 or iOS 9 0 that support Bluetooth Low Energy b Installation In google Play or Itunes store download PWS typing PreSens Wireless Studio Accept Privacy Policy of PreSens Wireless Studio 1 1 2 2 3 ...
Page 4: ...please check Bluetooth is activated on your smartphone A compatible device is nearby 10m the device to connect still has battery power the device to connect is not connected to another smartphone in this case the device is no longer visible for others smartphone Make sure that the App has permission access to your location 1 2 ...
Page 5: ... of replacement of the CAP From the PARAMETERS menu select Manual Calibration entering the calibration s parameters shown on the Final Inspection Protocol which comes with the replacement CAP It is also possible to select Barcode Calibration to read the barcode provided with the new CAP ...
Page 6: ...ers can be modified by pressing the value exple Humid Only the parameter Unit and sometimes Temperature measurement must be modified The change must be validated save or canceled cancel c Start a measurement Change O2 unit Androïd IOS ...
Page 7: ...continue and the data will be saved Only an action on STOP or PAUSE can interrupt the measurement d Export data From MEASUREMENTS menu you can access all the data recorded by the Oxymeter The data are sorted by timestamp By selecting a file name you can download the data on your smartphone or tablet in order to Display data on a chart SHOW DATA Export EXPORT format CSV XLSX PDF Delete DELETE 3 BAT...
Page 8: ...play NULL You have to wait a few hours and leave the batteries on the charger 4 CALIBRATION CHECK a Quick check You can check the calibration by performing an AIR measurement you need to set the temperature in manual mode first and enter the current temperature value Choose the O2 oxygen unit the value displayed should be 20 7 O2 more or less 0 5 b Deep check Add 100 mL water to a suitable vessel ...
Page 9: ...CONTACT winequalitysolutions vinventions com Mobile 33 6 84 42 71 88 Office 33 9 77 48 06 81 WWW WINEQUALITYSOLUTIONS COM Address 7 Avenue Yves Cazeaux 30230 Rodilhan France W W W VINVENTIONS COM ...