13
Installation
Pressurizing the pedestal using a portable
pump
!
WARNING! Do not
pressurize the pedestal beyond the
maximum safe working pressure indicated by the leading
edge of the red sector on the gauge. The pedestal is
fitted with a pressure relief valve as a safeguard against
over-pressurization.
Do not
attempt to adjust the
pressure relief valve.
To pressurize the pedestal using the Vinten portable *pump, proceed
as follows:
1.
Fully depress the moving column (1) and engage the safety catch
(2).
2.
Attach the intended payload, see
3.
Connect the pump adaptor (6) to the pedestal charging valve (4).
by screwing clockwise until finger tight.
4.
Connect pump hose (3) to the adaptor (6) and flip the lever
upwards to secure the pump to the adaptor.
5.
Position the pump between the legs, standing with both feet on the
pump feet.
6.
Grip the pump handle with both hands and using full steady
strokes, pressurize the pedestal to the required pressure. Do not
exceed the maximum working pressure, indicated by the leading
edge of the red sector on the gauge (5).
7.
Disconnect the hose (3) and adaptor (6) from the pedestal charging
valve, but do not refit the Schrader valve cap at this stage.
8.
Push the pump plunger fully down, and store.
*Pump model
may differ.
A
B
Note!
In the event that the pedestal air pressure has
dropped to 0 psi, proceed as follows:
Follow steps 3 to 4. The pump features a shock
function (Lever in Position A), this allows the pump to
store pressure with every stroke up to approximately
75psi. When this pressure is achieved turn the lever to
position B. This will force air in allowing the O-ring in
the pedestal to seal. Resume from step 5.
Summary of Contents for OSPREY lite
Page 1: ...User Guide Pedestal Part No V4169 0001 EN www vinten com Osprey Lite Pedestal ...
Page 7: ...5 Components and Connections Box Contents 1 Osprey Lite 2 Manual Pump 1 2 ...
Page 27: ...25 ...
Page 30: ...28 Notes ...
Page 31: ......
Page 32: ...Publication No V4169 4980 0 www videndum com ...