- 1 -

VINO1500CD, CTED 
VINO2500CD, CTED 

Installation Instruction 

 

1. Location 

 

  Place the wine cellar in a properly ventilated location. Otherwise, heat 

exhausted by the cooling unit will build up and it will not operate properly.  

  The exhaust area must not be closed space and must be ventilated. 

 
1) Rear Exhaust  

  Leave min 6 “clearance from the rear to the wall. 

  Leave min 12” clearance from the top to the ceiling. 

  Leave min 6” clearance from the left and right sides. 

 
2) Front Exhaust  

  Leave min 6” clearance from the front if left and right sides unobstructed. 

  Or, leave min 36” clearance from the front if left and right sides obstructed 

 

3) Top Exhaust  

  Leave min 12” from the top to the ceiling. 

  Leave min 2 “clearance from the rear to the wall. 

  Leave min 2” clearance from the left and right sides. 

 

4) Side Exhaust  

  Leave min 6 “clearance from the left or right side to the wall. 

  Leave min 12” clearance from the top to the ceiling.  

 

2. Installation 

 

Fig. 2.1 COOLING UNIT MOUNTING 