background image

TECHNICAL MANUAL

A100K10371 v.2.2

User Manual

PUBLIC ADDRESS & GENERAL 
ALARM SYSTEM

SPA-V2

TALK

+

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

ALL

B

AUX

DIM

SIGN

VOLUME

LS zone 1

Cabins

LS zone 2

LS zone 3

LS zone 4

Lifeboat area

PA microphone panel

PA microphone & Alarm panel

Alarm panel

Entertainment

LS zone 5

LS zone 6

Engine

area

Open deck

GENERAL

ABANDON

MANUAL

RESET

EMS

SPARE

SPA-A6CD

1

2

3

4

5

6

ALL

SPA-M6D

TALK

DIM.

Open deck

ACM Integrated System

ACM Telephone System

Telephone

PABX

Accommodations

Weatherproof

ZONE 1  

ZONE 2  

ZONE 3  

ZONE 4  

ZONE 5  

ZONE 6  

GENERAL

  ALARM  

ABANDON

   ALARM  

MANUAL

 ALARM  

 EMERGENCY 

         PA 

Summary of Contents for SPA-V2

Page 1: ...S zone 4 Lifeboat area PA microphone panel PA microphone Alarm panel Alarm panel Entertainment LS zone 5 LS zone 6 Engine area Open deck GENERAL ABANDON MANUAL RESET EMS SPARE SPA A6CD 1 2 3 4 5 6 ALL...

Page 2: ...in this publication or for damages arising from the information in it No information in this publication should be regarded as a warranty by Zenitel Norway AS The information in this publication may b...

Page 3: ...Alarm Start with SPA AC6 and SPA AC6 D 6 2 5 Broadcast a PA message with SPA W1 V2 SPA W1 D 7 2 6 Alarm Start PA message with SPA W1AR V2 SPA W1AR D 7 2 7 Alarm Start PA message with SPA W6A4 SPA W6A4...

Page 4: ...s and General Alarm System is designed to meet the requirements in accordance with SOLAS Chapter III part B regulation 6 4 and 6 5 MSC 48 66 International Life Saving Appliance LSA Code MSC Circ 808 P...

Page 5: ...or local PA panels SPA M1 V2 panels are used in a single system while SPA M1 D panels are used in a dual system Single or dual panel systems are configured according to project specifications at deliv...

Page 6: ...ALK button 3 Speak close to and clearly into the microphone to broadcast the message Operation with handheld microphone ETC 1 TB 1 Select the zone 2 Press and hold the PTT Switch 3 Speak close to and...

Page 7: ...ess the button labeled EMERGENCY PA to activate the Emergency PA message Hold the button when speaking into the microphone of the associated microphone panel Releasing the Emergency PA button will aut...

Page 8: ...it can be used as a PA panel or Alarm or in combination The Alarm part can start three alarms including GENERAL ALARM and EMERGENCY PA The panel is equipped with a protective cover for the alarm push...

Page 9: ...LED The alarm message will be muted 2 Press the PTT Switch Speak close to and clearly into the microphone to broadcast the message To end the Emergency function Release the PTT Switch and the PA syste...

Page 10: ...Emergency operation Press the desired LINE button The Public Address call is set up indicated by a steady green LED Emergency operation Press the ALL button The Public Address call is set up indicate...

Page 11: ...sh with 4x4 mm screws SPA BOXM1 Optional wall mounting box Dimension 96W x 96H x 80D mm Cabling Pluggable screw terminals max 2 5 mm2 cable Cable glands 2 x PG 16 Weight Approx 0 4 Kg Protection IP 44...

Page 12: ...greed in writing with Zenitel Any authorized reproduction in part or in whole must include this legend Zenitel All rights reserved The WEEE Directive does not legislate that Zenitel as a producer shal...

Reviews: