FASTENING MOUNTING BRACKETS

A.

Position the indentions on each bracket (see diagram below) at the desired fabric location. These indentions
designate where the tube edges should lie once the shade roller is in place. Use a level to ensure both brackets are
at the same height and parallel to the window casing. 

Note: 

Fasten the top of the brackets 8 1/2 in. (220 mm) from the top of the window trim to ensure complete

window exposure when the shades are in full open position.

B.

Fasten the brackets to studs in the wall using no less than six (6) hex-head self-drilling screws.

Note: 

All six (6) screws must be securely fastened to a stud or other structural member.

CAUTION!

Sivoia

®

High Torque Roller Shades can weigh up to 225 lbs. (102 kg), depending on the size and

fabric type. Make sure the mounting brackets are fastened to structural elements rated to support such loads.

Before AND after the mounting brackets have been fastened to the wall, confirm the 

Tube Length

dimension (see pg. 3). Make any necessary bracket position adjustments based on this assessment.

Bracket Indentions as guides

for Tube Edges

Bracket Indentions as reference

for Tube Edges

Wall Mount

Ceiling Mount

Ceiling Mount

Wall Mount

8 1/2”
(22 cm)

Tube Length

2

Summary of Contents for LUTRON Sivoia SV-MDU-HT-W-L

Page 1: ...r Module A Typical Sivoia Motorized Shade System Wallstation Controls SV IR Infrared Receiver Module and Infrared Handheld Transmitter not included with this kit IMPORTANT NOTES These instructions app...

Page 2: ...High Torque Axle MDU Idler Support Mounting Brackets right mount equipment shown 1 2 in 13 mm Idler and MDU Truss head Screws x8 2 1 2 in 64 mm Hex Head Self Drilling Screws x12 2 Phillips Screwdrive...

Page 3: ...32 F 122 F 0 C 50 C 2 Depending on the height of the shade tube width can be up to 1 4 in 6 4 mm wider than the specified Fabric Width FW 3 Measure Tube Length see diagram below and use this dimensio...

Page 4: ...s to studs in the wall using no less than six 6 hex head self drilling screws Note All six 6 screws must be securely fastened to a stud or other structural member CAUTION Sivoia High Torque Roller Sha...

Page 5: ...s hexagonal drive ball You may need to rotate the roller in order to push the shade over the hexagonal drive ball C Insert the idler pin into the slot of the idler support and drop it into place Make...

Page 6: ...e idler support is considered to be in the locked position when the idler pin cannot be removed from the idler support slot see diagram below Idler Support Locked Shade Retaining Leveling Screw CAUTIO...

Page 7: ...ect wires to the terminal block according to the diagram below D Replace the terminal block and the terminal block cover Wire to a Sivoia plug in transformer junction box mount transformer or a Sivoia...

Page 8: ...nal Blocks Control Comm Link Comm Link Power Supply Control Next MDU Next MDU Comm Link Power Supply Wire Type Control Description 2 conductors 22 24 AWG 3 conductors 2 shielded 1 drain 24 AWG Belden...

Page 9: ...the Close Limit The display will read and blink for 4 seconds then go blank SET OPEN CLOSE MODE Open Limit The position the shade moves to when it opens Close Limit The position the shade moves to wh...

Page 10: ...individual keypads interfaces can be wired to the same MDU A maximum of 9 keypads interfaces can be wired to one MDU There are two types of Sivoia keypads and interfaces group and individual types The...

Page 11: ...ely 4 seconds until appears in the MDU s LED display OPEN PRESET CLOSE PRESS ONCE Shade goes to open limit PRESS ONCE Shade goes to close limit PRESS To close shade PRESS To open shade PRESS ONCE Shad...

Page 12: ...to five 5 SV IR EXT 10 extension cables 10 ft 3 m each Note To control an individual shade with an IR transmitter the SV IR must be connected to that MDU If there is a Group Subgroup of MDU s with th...

Page 13: ...ar may be binding on the roller frame or end brackets Check for and clear all obstructions The shade does not respond to control 1 Check that power is connected to the shade 2 Check that the wall keyp...

Page 14: ...02 mm 7 95 202 mm 5 4 137 mm 5 127 mm 3 4 87 mm 4 25 108 mm MDU Mounting Bracket Idler Mounting Bracket MDU Dimensions Side View A Side View B Front View Front View Side View Front View Side View Back...

Page 15: ...Page 15 shading solutions byVIMCOTM Notes...

Page 16: ...ents and equipment external to the SIVOIA Motorized Window Shade System such as a Non Lutron lighting and automation systems b Building wiring and c Other manufacturers equipment including but not lim...

Reviews: