02692 - Ceiling-mounted connected radar sensor 

SMART HOME VIEW WIRELESS

Thanks to UWB (radar ultra wide band) ultra-low power technology, the sensor is capable of 
detecting presence and possible fallen people with the utmost precision. The device is fitted 
with an input for external wired contact which can be configured to control the activation of the 
relay or to activate the scenarios in the View Wireless system. The front push button starts the 
configuration with the View Wireless App and the LED signals the status of the relay.

TWO OPERATING MODES (ALTERNATIVE)

 

Stand alone 

 

View Wireless System

Download the View Wireless 

 App from the stores onto the tablet/smartphone you 

will be using for configuration.

Depending on the mode you select, you will need:

Stand alone

View Wireless System

Nothing else

Gateway art. 30807.x-20597-19597-16497-14597 

View App  

 for management via smartphone/tablet 

When the device is powered for the first configuration, we recommend you search for any 
new firmware and perform the update. 
Create your Installer account on MyVimar (on-line).

STAND ALONE CONFIGURATION

1.

 Wire all the radar sensors.

2.

 Start the View Wireless App and log in with the credentials you just created.

3.

 Create the system and the environments.

4.

 Associate all the sensors with the environments.

To associate the radar sensor:
• Select “Add” ( 

 ), choose the environment to place it and give it a name

• Select   ; activate the Bluetooth connection on your tablet/smartphone and approach the 

radar sensor

• Press the front push button to start the Configuration phase

5.

 For every device, set the function, the parameters and any accessory devices (wired or radio 

control and related function). 

CONFIGURATION 

IN THE VIEW WIRELESS SYSTEM

 

1.

 Wire all the devices in the system (radar sensors, 2-way switches, thermostats, gateway, etc.). 

2.

 Start the View Wireless App and log in with the credentials you just created.

3.

 Create the system and the environments.

4.

 Associate all the devices with the environments, except for the gateway (which should be 

associated last).
To associate the radar sensor:
• Select “Add” ( 

 ), choose the environment to place it and give it a name

• Select   ; activate the Bluetooth connection on your tablet/smartphone and approach the 

radar sensor

• Press the front push button to start the Configuration phase

5.

 For every device, set the function, the parameters and any accessory devices (wired or radio 

control and related function).  

6.

 Transfer the configuration of the devices to the gateway and connect it to the Wi-Fi network.

7.

 Transfer the system to the Administrator user (who must have created his/her profile on 

MyVimar).

For details please refer to the View Wireless App manual you can download from www.
vimar.com 

 DOWNLOAD 

 View Wireless MOBILE 

 App

Summary of LED signals

• During normal operation (default colours):

LED

Meaning

On white

Relay active

Off

Relay not active

On red 

Fall detection

Flashing white

Manual forcing

(Relay active without timer activated/deactivated with

front push button pressing)

• In the configuration phase:

LED

Meaning

Flashing blue 

(for max 2 min.)

Pending receipt of a fw update

1 green flash

Connection established with View Wireless

Blue permanently lit

Device associated with the smartphone via Bluetooth

1 white flash

Device reset

RESETTING THE DEVICE.

The reset restores the factory settings. Within the first 5 minutes from powering, press the front 
push button 

for 30 s until the white LED flashes. 

 INSTALLATION RULES.

• Installation and configuration must be carried out by qualified persons in compliance with the 

current regulations regarding the installation of electrical equipment in the country where the 
products are installed.

• Installation must be carried out with the system switched off. 
• The OUT terminals are separated by double insulation from the L-N-P terminals. Do not 

connect a mains voltage circuit to the OUT terminals; these terminals can be connected to 
SELV and ELV circuits according to the characteristics stated.

• Connect a double insulated cable or a reinforced cable type 01840.E to the OUT terminals.
• Use a cable with sheath for terminals L-N-P (type H05RN-F) with the dedicated cable clamp.
• The device may only be used for indoor applications.
• Metal objects in front of the detector tend to alter its operation. Avoid installations where metal 

surfaces are present in the radar’s field of detection.

• The technology used is capable of detecting presence even through certain types of material 

(for instance plasterboard, thin walls, fabric and wood), so suitable installation in the room is 
necessary, as is the appropriate configuration of the maximum detection range.

• Do not install on partitions or walls subjected to shock and vibration.
• This device is compliant with the reference standard, in terms of electrical safety, when it is 

installed as specified in the instructions and with the accessories supplied. If the device is used 
for purposes other than those specified by the manufacturer, the protection provided may be 
compromised.

• Do not cover the detection range of the detector.
• Install the device at a distance of more than 2 m from any Wi-Fi 6E antennae.
• After the configuration phase (or after changing parameters) and every time it is switched on, 

the detector performs an initial calibration phase lasting 45 s at the end of which it becomes 
operational; during this phase, detection may not be precise. 

•  Presence detection of a sleeping person only occurs correctly if the subject is entirely inside the 

detection area.

CHARACTERISTICS:

• Rated supply voltage: 100-240 V~, 50/60 Hz.
• Max. power absorption from the mains: 1.1 W
• Output contact: 24 VAC or 30 VDC, 400 mA max (SELV and ELV), not suitable for controlling 

electrical locks

• Bluetooth technology: 

-  RF transmission power: < 100 mW (20 dBm)
-  Frequency range: 2400-2483.5 MHz

• UWB radar: 

-  RF transmission power: < 1mW (0 dBm)
-  Frequency range: 7.3÷8.5 GHz

• Terminals:

-  2 terminals (L and N) for line and neutral
- 1 terminal (P) for connection to the remote wired control (for instance art. 30008-20008-

19008-16080-14008). 

The max distance between the IoT device and the push button is 

50 m with a cable with a minimum cross-section of 1.5 mm

2

 

-  2 terminals (OUT) for the potential-free signal relay output for SELV and ELV circuits

• Front push button for configuration/reset and for manual forcing (in configurations in which this 

mode is allowed).

• RGB LED indicating the output status (which can be set from the View Wireless App) and the 

configuration status

• Operating temperature: -10 ÷ +40 °C (indoor)
• Protection degree: IP20
• Configuration via View Wireless App for View Wireless system in Bluetooth technology
• Controllable via View App

• Detection of a fall is to be considered an auxiliary function which generates useful 

information to highlight conditions of danger, but it must not be deemed a substitute for a 
medical/life-saving device.

OPERATION

Operation, and therefore the management of the relay, widgets and notifications displayed by 
the View App are connected to the setting assigned to the parameters during the configuration 
phase. 

Presence function

 

The presence in the detection area is signalled in the View App for the full duration plus the 
absence check time (75 s). At the end of this time, the relay is deactivated with a delay that can 
be set between 1 s and 16 hours.

PRESENCE

RELAY

absence check t

relay off t

75 s