Vilpe Eco deal Installation And Operation Manual Download Page 1

Installation and Operation

instructions

VILPE® ECo Ideal Wireless 

RH

A

B

C

A

: Status LED     

B

: Mode LEDs     

C

: Touch button

About this manual

1.1 

About the device 

The VILPE® ECo Ideal Wireless RH is a user control and humidity 
sensor for a ventilation system. The device communicates information 
about ventilation speed request and system status via wireless 
communications with the central control device.

1.2  How to use this manual

This manual is intended as a reference book by which qualified install-
ers can install the VILPE® ECo Ideal Wireless RH (henceforth called 
“device”) and users can use the device for its intended purpose. Make 
sure you have read and understood the manual before you install and/
or use the device.

1.3 Original 

instructions 

The original instructions for this manual have been written in English. 
Other language versions of this manual are a translation of the 
original instructions.

1.4 Admonitions

   

NOTE

’Note’ is used to highlight additional information.

2 Safety 

2.1 Directives

Hereby, SK Tuote Oy declares that the radio equipment type VILPE® 
ECo Ideal Wireless RH is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the 
following internet address: www.vilpe.com/conf
The device meets the following EC directives:
• RTTE directive: 1999/5/EC
• RoHS directive: 2002/95/EC
• WEEE directive: 2002/96/EC

2.2  Signs on the unit

CE marking of conformity
Use of the device may not be legal in every member state.

Waste electrical products should not be disposed of with general 
waste.Please recycle where these facilities exist. Check with your 
local authority for recycling advice. 2002/96/EC (WEEE).

2.3  General safety instructions

The device is designed for indoor use only. Do not expose the device 
to rain or moisture, to avoid short circuit. Short circuit may cause fire 
or electric shock hazard. Operate the device between 0°C and 40°C. 
For cleaning of the device use a soft damp cloth only. Never use any 
abrasive or chemical cleaner. Do not paint the device.

2.4 Batteries

Batteries shall not be exposed to excessive heat such as sunshine, fire 
or the like; danger of damage if battery is incorrectly replaced.Batteries 
should not be disposed of with general waste. Please recycle where 
these facilities exist. Check with your local authority for recycling advice.

3 Description

3.1 Intended 

use

The device is designed for following purposes:
1   To set the speed level of ventilation through the fan speed, based 

on user input or measured humidity level.

2  To set parameters for the ventilation control.
Every other or further use is not in conformance with the intended use.

3.2 Working 

principle

The device communicates with the control device using wireless com-
munications, in order to control the ventilation. Via the button and 
LEDs you can read and set the mode of control that the ventilation 
system currently is in. When in Auto mode, the device requests the 
level of ventilation based on the relative humidity (RH).

3.2.1 Ventilation speeds and modes

The ventilation system runs in one of the following modes. In each 
of these modes, the control device sets the ventilation system to a 
configured level of ventilation.

• Away mode: 

 

Low fan speed

• Home mode: 

   

Medium fan speed

• Timer mode: 

    

High fan speed, for a restricted duration. 

• Auto mode: 

Auto

    

Between Low fan speed and High fan  

 

speed, based on measured values. 

The control device drives the fan based on the highest of values sent 
by the bound wireless sensor(s). When you start the timer mode from 
this device, the ventilation will be active for 30 minutes.

3.2.2  RH measurement

The device continuously measures the relative humidity (RH) in the 
air. When in Auto mode, the device controls the ventilation based on 
the course of the measured values: the ventilation starts when the 
humidity gets above a certain level, or for some time when the humid-
ity suddenly increases.

   

NOTE  

The device stores the configured fan speed values in the control 

device, and requests them from there. The device stores the RH 
setpoint itself, and does not communicate this with any other device.

3.3 Visual 

signals

Status LED

Mode LEDs

Auto

Startup

White Continuous

On

On

On

On

System status

Green Continuous Status 

OK

Red

1 flash 

Com. error

4 flashes  RH sensor error
5 flashes 

Low battery

Selecting

Away mode

Off

Home mode

Timer mode

Auto mode

   

NOTE  

When setting the fan speeds, make sure that the medium 

fan speed is between the low fan speed and the high fan speed.

4 Operation

4.1 Show 

status

 Tap the button. The Status LED and Mode LEDs show the status 
of the system. 

4.2 Set 

mode

From the status screen:

Tap the button. The mode LEDs show the next selection.

 If needed, tap the button within 2 seconds.
Repeat until the selection shows the required mode.

 Wait 2 seconds.  The device applies the requested mode.
The Status LED and Mode LEDs show the status of the system.

5 Installation

5.1 Preparation

   

NOTE

  

Do not place the device in a metal casing.

1    Press the clip and pull the top section from the 

bottom section. 

     When you do not place the device on a flush 

mounted wall box:

     When the wall material needs preparation, use 

the mounting plate as a template.

5.2 Commissioning

1   Place the batteries. 

All LEDs are ON for 3 seconds.

2   Wait until the status LED shows the binding 

mode. 
If the device shows another indication, the 
device is already bound. See 6.2 on how to 
bind the device again.

3   Tap the button. The device will try to bind to 

the control device, and shows the result on the status LED. When 
the communication failed, make sure that the control device is in 
binding mode, and retry.

5.3 Installation 

procedure

1   Place the bottom section of the device. 
2   Fasten the bottom section using the 

screws.

5.4  Close top section

1    Place the top section of the device onto 

the bottom section.
   a.  Place the clips.
   b.   Close and press until it clicks.

6 Configuration

6.1 Configure 

settings

From the status screen (see 4.1):

 Tap the button.
The mode LEDs show the next selection. 

 If needed, tap the button within 2 seconds. Repeat until the 
selection shows the item to configure.

 Press and hold the button until the Status LED starts flashing 
white.

 Release the button.
The status LED shows the item selected, and the Mode LEDs 
show its current value.

 If needed, tap the button within 10 seconds, until the Mode LEDs 
show the value to set.

    

   

NOTE

When setting the fan speeds, make sure that the medium 
fan speed is between the low fan speed and the high fan 
speed.

 Wait 10 seconds.
The device applies the configured value. 
The Status LED and Mode LEDs show the status of the system. 

6.2  Bind the device again

From the status screen:

Tap the button.  The mode LEDs show the next selection. 

 If needed, tap the button within 2 seconds, until the selection 
shows the 4

th

 LED.

 Press and hold the button until the Status LED starts flashing 
white.

Release the button. The status LED shows the binding mode. 

 Tap the button. The device will try to bind to the control device.
It shows the result on the status LED. 

6.3  Perform a factory reset

From the status screen:

Tap the button.  The mode LEDs show the next selection. 

If needed, tap the button within 2 seconds, until the selection 

shows the 4

th

 LED.

Press and hold the button until the Status LED starts flashing 

white.

Release the button. The status LED shows the binding mode. 

Press and hold the button for 10 seconds.

The status LED shows white.

Release the button. The device releases its binding and restarts. 

The device will return to the binding mode.

Replacing the battery

See 5.1, 5.2 and 5.4 for visual instructions.

8 Technical 

data

8.1 Dimensions

       Overall dimensions (h x w x d):     

 100 x 100 X 25 mm

       Weight: 

 

   

± 125g

8.2 Ambient 

conditions

       Operating Temperature Range:    

0 to 40 °C

       Shipping & Storage Temperature Range:  -20 to 55°C
       Relative Humidity: 

 

   

 0 - 90%, 
non-condensing

       Ingress protection (IEC60529):     

IP30

8.3 Battery 

specification

       Type: 

 

   

AA battery, 2x

       Battery lifetime: 

 

   

2 years

8.4  Wireless connection specifications

       Communication frequency: 

   

868.3 MHz

       Output power: 

 

   

at least 0 dBm.

       You are not allowed to use the device outside of Europe.

8.5  RH measurement specifications

       Measurement range:   

   

0 – 100 % RH 

       Measurement accuracy
             •   at 11-89%RH:   

   

3% RH 

             •   at 0-10% and 90-100%:     

7% RH

       Measurement resolution: 

   

1%RH

       Measurement stability: 

   

1.5%RH over 5 years

Status LED

Mode LEDs

Auto

Configuration

Step 

1

 Low fan speed

Off

 Medium fan speed

 High fan speed

  Binding

Step 

2

Value

Blue/red

 

Low fan speed Off 10% 20% 30% 40%

Blue/green

 Medium fan speed 30% 40% 50% 60% 70%

Red/green/blue

 

High fan speed 60% 70% 80% 90% 100%

Red/green

  

Binding

SK Tuote Oy

Kauppatie 9
FI-65610 Mustasaari FINLAND

Sales and technical support

Tel. +358 20 123 3222
[email protected]

T80091

/ECO

Summary of Contents for Eco deal

Page 1: ...or 4 ashes RH sensor error 5 ashes Low battery Selecting Away mode Off Home mode Timer mode Auto mode NOTE When setting the fan speeds make sure that the medium fan speed is between the low fan speed...

Page 2: ...Abwesen heitsmodus Aus Home Modus Timer Modus Auto Modus HINWEIS Wenn Sie die L ftergeschwindigkeiten einstellen achten Sie darauf dass die mittlere L ftergeschwindigkeit Zwischen der niedrigen L fter...

Page 3: ...n 1 v l hdys Kommuni kaatiovirhe 4 v l hdyst Kosteus mittarivika 5 v l hdyst Akunvirta v hiss Valitaan Poissa tila Poisp lt Kotona tila Ajastin tila Automaattinen tila HUOM Kun asetat puhaltimen nopeu...

Page 4: ...vare 5 blinkningar L g batteriniv Val Borta l ge Av Hemma l ge Timer l ge Auto l ge OBS N r du st ller in kthastigheterna m ste du f rs kra dig om att niv n medel ligger mellan den l ga och h ga kthas...

Page 5: ...eren Batterij bijna leeg Selecteren De modus Afwezig Uit De modus Thuis De modus Timer De modus Auto OPMERKING Bij het instellen van de ventilatorsnelheden zorg ervoor dat de middelmatige ventilatorsn...

Page 6: ...nts Erreur capteur HR 5 clignotements Batterie faible S lection Mode Sorti Arr t Mode la maison Mode Minuterie Mode Auto REMARQUE Pour d nir les vitesses du ventilateur v ri er que la vitesse moyenne...

Page 7: ...czujnika RH 5 migni Niski poziom na adowania baterii Wyb r Tryb Poza domem Wy Tryb W domu Tryb Zegar Tryb Automatyczny UWAGA Podczas ustawiania pr dko ci wentylatora nale y pami ta aby pr dko rednia...

Page 8: ...ay Home Timer Auto 30 3 2 2 RH 3 3 Auto 1 4 5 4 4 1 1 4 2 1 2 2 3 2 5 5 1 1 5 2 1 3 2 6 2 3 5 3 1 2 5 4 1 a b 6 6 1 4 1 1 2 2 3 4 5 10 6 10 6 2 1 2 2 4 3 4 5 6 3 1 2 2 4 3 4 5 10 6 7 5 1 5 2 5 4 8 8 1...

Reviews: