background image

5

Zone 1

Zone 2

Zone 3

Zone 4

©

MODEL ZPI-4 

VIKING

ELECTRONICS

HUDSON, WI 54016

FOUR ZONE PAGING INTERFACE 

OPTIONAL MUSIC AMP 

OUT TO AMP'S (+) INPUT  

OUT TO AMP'S (-) INPUT  

IN FROM AMP'S (+) OUTPUT  

IN FROM AMP'S (-) OUTPUT  

TELCO IN 

TELCO OUT

MUSIC IN 

MUSIC OUT 

INPUT CONTACTS 

OUTPUT CONTACTS 

NIGHT RING 

NIGHT CONTACTS 

POWER

13.8 VAC

PWR

NIGHT

WARBLE
VOLUME

PAGE

ALERT

VOLUME

PAGE

VOLUME

MUSIC

VOLUME

+

+

+

+

1

2

3

4

5

6

7

8

9 10 11 12 13 14 15 16

OPTIONAL PAGING AMP 

OUT TO AMP'S (+) INPUT  

OUT TO AMP'S (-) INPUT  

IN FROM AMP'S (+) OUTPUT  

IN FROM AMP'S (-) OUTPUT  

VIKING

1  2  3  4  5  6  7  8

Paging

Amplifier

(not included)

Input

Output

In this mode, one external amplifier handles both paging and background music. An internal relay capable 
of switching between paging signal and music signal sends input to this amp, the amplified signal is returned 
and the 

ZPI-4

 sends it to the correct zone(s).  

Advantages:

 Up to a 350 watt amplifier may be used when driving 70V speakers, only one amplifier is 

required. 

Limitations:

  The amplifier needs to be limited to 200 watts, each speaker zone is limited to an 8 ohm 

minimum impedance, the amplifier must be able to drive the speakers of all zones (Example:  4 zones at 8 
ohms per zone equals a 2 ohm load during an all call); if background music is used, all zones will receive 
background music and it will be muted in all zones during a page.

 

To set up the 

ZPI-4

 in the single amplifier mode:

3.  Single Amplifier Mode 

Step 1.

 Attach ZONE 1 screw terminals to the speaker(s) for Zone 1.

Step 2.

Repeat step 2 for each of the remaining three zones.

Step 3.

Attach the paging amp as shown in the diagram.

Step 4.

Set DIP switch 1 to the ON position.  This tells the 

ZPI-4

 that it is operating in the single amplifier 

mode.

Summary of Contents for ZPI-4

Page 1: ...30 x 1 80 Shipping Weight 1 5 kg 3 2 lbs Environmental 0 C to 32 C 32 F to 90 F with 5 to 95 non condensing humidity Relay Contacts 5 Amps 30V DC 250V AC each 350W 70V 200W 8Ohm REN 0 5 A Artificial...

Page 2: ...2 3 on 4 5 OFF ON DIP Switches Note Remove these shunts to eliminate background music for each zone individually except Single Amplifier Mode IMPORTANT Electronic devices are susceptible to lightning...

Page 3: ...BATT switch to the OFF position all the way to the left Step 3 Attach a pair of wires from the paging port to the TELCO IN screw terminals Step 4 Attach the background music source if required to the...

Page 4: ...tputs and speakers Step 1 Attach the ZONE 1 screw terminals to the speaker s for Zone 1 Step 2 If background music is to be enabled on this zone ensure that the ZONE 1 music shunts are in place coveri...

Page 5: ...ends input to this amp the amplified signal is returned and the ZPI 4 sends it to the correct zone s Advantages Up to a 350 watt amplifier may be used when driving 70V speakers only one amplifier is r...

Page 6: ...e volumes will work independently Step 13 Set the TIME OUT ADJUSTMENT on the Secondary to the maximum time clockwise Step 14 Plug the power supply adapter into the power jack of the Secondary and the...

Page 7: ...the ZPI 4 activates the selected zone s See table to the right Touch Tone Zone s 1 1 2 2 3 3 4 4 5 1 2 6 2 3 7 3 4 8 1 2 3 9 2 3 4 0 1 2 3 4 ALL Touch Tone Primary Unit Zone s 11 1 1 12 1 2 13 1 3 14...