REPEATER PROGRAMMING
5-2
October 1999
Part No. 001-2009-201
Table 5-1 REPEATER SETUP PARAMETERS
Parameter
Response
Description
Repeater Number
1-20
Each repeater is assigned a Home Repeater number from 1-
20.
Channel Number
1-399
Each repeater is programmed with a number of the channel
that it is operating on.
Telco Network Type
None
FSK
RS232
FSK Blank & Burst
TIC
VNC
Data signaling type for RNT, FSK, RS232 or FSK B&B.
None=LTR dispatch only.
TIC is for Telephone Interface Card w/o RNT.
VNC=network telephone interconnect w/o RNT.
Area
0, 1
Same as value of the Area bit in the mobiles.
Sync Repeater
Yes, No
Not used.
Stand Alone
Yes, No
Select if the repeater is not connected to additional repeaters
(via HSDB).
ID Validator
Yes, No
Not used.
CWID Time
0 = disabled
1-60 min
Time between CWID transmissions.
CWID Message
15 characters/numbers
UPPER CASE
Station call letters.
Local MIC ID
0 = disabled (default)
1-250, 253
Group ID transmitted when the local microphone PTT is
active.
Test Mode ID
0 = disabled
1-250,
254 (default)
Group ID transmitted when the Repeater is in the Test Mode.
RF Power Level
25-75, 75-160
Power level in watts for transmit power.
Power Source
AC or DC
The type of primary power source for the Repeater.
Paging
Yes, No
Select if a paging terminal is installed.
Data Modem
Yes, No
Select if the Data Modem option is installed.
Summary of Contents for VX 900 MHz LTR
Page 2: ...1 2 October 1995 Part No 001 2008 202...
Page 4: ...1 4 October 1995 Part No 001 2008 202...
Page 24: ...INTRODUCTION AND OPERATION 1 10 October 1999 Part No 001 2009 201...
Page 26: ...INTRODUCTION AND OPERATION 1 12 October 1999 Part No 001 2009 201...
Page 40: ...INSTALLATION 2 14 October 1999 Part No 001 2009 201...
Page 56: ...PULL DOWN MENUS 4 12 October 1999 Part No 001 2009 201...
Page 60: ...REPEATER PROGRAMMING 5 4 October 1999 Part No 001 2009 201...
Page 142: ...SERVICING 8 8 October 1999 Part No 001 2009 201...