© 2009 Viking Preferred Service
25
Induction Switch
The purpose of the surface switch is to control the
cooking operation. Once the end user chooses a
setting, the corresponding amount of power and
cycle rate to deliver a given output is sent to the
interface board. The interface board communicates
between the indicator and the generator. The
indicator communicates if a pot is in place. The
generator receives input to power the inductor and
deliver the desired output.
Boost Function – The boost function is operated
like a normal cooking function. If the small coil
is on, the boost function will be canceled when
the total power is over 3700 watts. The boost
function has to reset if the lower wattage element
is turned off, or if the element is turned to a lower
setting of a maximum 3700 watts within the first 10
minutes of operation. The 10 minutes starts when
the 3700 watts (3200watts) is turned on. When
the lower wattage element is turned on, power
will be reduced from 3700 watts (3200 watts) to
2300 watts when the power consumption from the
generator is over 3700 watts. The boost function is
available on the RR (VCCU 30/36”), LF (VICU 30”),
LF and RR (VICU 36”) models.
To access the surface switch, remove the control
knobs, switch securing screws/nut, perimeter screws
securing main top, main top and the switches are
now accessible.
The switch is a 10K potentiometer. Measure the
resistance at different switch settings. If no reading or
an open occurs, the switch is bad. Resistance should
be approximately 12300
Ω
in off position, 10000
Ω
in simmer, 9130
Ω
in low, 8540
Ω
in medium-low,
7800
Ω
in medium, 3650
Ω
in medium-HI, and 0
Ω
in HI.
Induction Switch Resistance Chart
Setting
Resistance
Off
12300
Ω
+/- 50
Ω
Simmer
10000
Ω
+/- 50
Ω
Low
9130
Ω
+/- 50
Ω
Medium-Low
8540
Ω
+/- 50
Ω
Medium
7800
Ω
+/- 50
Ω
Medium-High
3650
Ω
+/- 50
Ω
High
0
Ω
Measured from positions 2 and 3
Service Diagnostics and Procedures
2 3 4 5
Test Points
1
Element
Off
HI
9
8
7
6
5
4
3
2
1
Simmer
210mm
0
3500
2300
1472
966
644
414
276
184
115
69
58
210mm
0
3220
2300
1472
966
644
414
276
184
115
69
58
180mm
0
1850
1850
1184
777
518
333
222
148
93
56
46
145mm
0
1100
1100
90
462
308
198
132
88
55
33
28
Max Time (min.)
0
10
90
113
139
170
212
260
318
402
520
520