background image

P

P

r

r

a

a

c

c

t

t

i

i

c

c

e

e

T

T

E

E

L

L

E

E

C

C

O

O

M

M

S

S

O

O

L

L

U

U

T

T

I

I

O

O

N

N

S

S

F

F

O

O

R

R

T

T

H

H

E

E

2

2

1

1

S

S

T

T

C

C

E

E

N

N

T

T

U

U

R

R

Y

Y

TECHNICAL

TECHNICAL

SRC-1

SRC-1

Secure Relay

Controller

October 23, 2008

P

P

h

h

o

o

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

8

8

6

6

1

1

Power:

12 to 24V AC or DC, 12V DC adapter provided

Shipping Weight:

0.64kg (1.4 lbs)

Dimensions: 

133mm x 89mm x 44mm (5.25” x 3.5” x 1.75”)

Environmental: 

0°C to 32°C (32°F to 90°F) with 5% to 95%

non-condensing humidity

Talk Battery Output:

32V DC

Relay Contact Ratings:

5A @ 30V DC / 250V AC maximum

Connections:

9 position screw terminal strip

Securely Operate a Doorstrike and

Provide Keyless Entry

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

F

F

e

e

a

a

t

t

u

u

r

r

e

e

s

s

•  User touch tone programmable
•  Non-volatile memory - retains programming 

during power outage

•  6 digit programmable security code (to access 

programming)

•  Switchable 32V talk battery
•  Programmable relay activation time
•  Programmable relay activation code (1-2 digits 

or 

)

•  Operates on any 12-24V AC/DC power source
•  LED’s for power / relay activation
•  Programmable allow / restrict for dialing from 

entry phone

•  Programmable allow / restrict for keyless entry

from entry phone

•  32 keyless entry codes
•  Trigger input for contact closure from postal

lock, request to exit, etc.

The 

SRC-1

enables a standard touch tone phone to

securely operate a set of timed relay contacts to control a
doorstrike or gate controller at a remote location. The

SRC-1

is fully user programmable and uses non-volatile

memory. The 

SRC-1

eliminates the possibility of dialing

the activation code through the entry phone using a hand
held touch tone dialer.

The 

SRC-1

features a switchable 32V talk battery to allow

use with any of Viking’s entry phones (E Series), door-
boxes (W Series) or hot-line/panel phones (K Series).

The 

SRC-1

is installed between the entry phone and the secure phone, and will reject touch

tones from the entry phone and only operate the relay if the correct activation code (user pro-
grammable) is given from the secure phone.

The 

SRC-1

also provides up to 32 keyless entry codes to operate the relay from the entry phone

with 1 to 6 digits. This feature can be disabled in programming for increased security.

Secure control of:

•  High security building entry systems

•  Door strikes and gates in conjunction with door

boxes (

W-1000

, etc.), entry phones (

E-10A

E-20B

E-30

E-40

E-50

K-1700-3

, etc.) or 

hot-line/panel phones (

K-1500-7

K-1900-7

, etc)

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

h

h

t

t

t

t

p

p

:

:

/

/

/

/

w

w

w

w

w

w

.

.

v

v

i

i

k

k

i

i

n

n

g

g

e

e

l

l

e

e

c

c

t

t

r

r

o

o

n

n

i

i

c

c

s

s

.

.

c

c

o

o

m

m

i

i

n

n

f

f

o

o

@

@

v

v

i

i

k

k

i

i

n

n

g

g

e

e

l

l

e

e

c

c

t

t

r

r

o

o

n

n

i

i

c

c

s

s

.

.

c

c

o

o

m

m

Summary of Contents for SRC-1

Page 1: ...or contact closure from postal lock request to exit etc The SRC 1 enables a standard touch tone phone to securely operate a set of timed relay contacts to control a doorstrike or gate controller at a remote location The SRC 1 is fully user programmable and uses non volatile memory The SRC 1 eliminates the possibility of dialing the activation code through the entry phone using a hand held touch to...

Page 2: ...i ate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense FCC REQUIREMENTS This equipment complies with Part 68 of the FCC ru...

Page 3: ...ONE RELAY CONTROLLER MODEL SRC 1 LINE IN 1 2 3 4 7 8 9 ENTRY DEVICE 5 6 TRIGGER INPUT PWR RLY TALK BATTERY RELAY OUTPUT POWER 12 VDC VIKING ELECTRONICS HUDSON WI 54016 JP1 JP1 Normal Position 4 3 2 1 Learn Position A Entering the Programming Mode 1 Programming with Line Powered Entry Phone Connected Talk Battery OFF Step 1 Call into the C O line or PABX extension connected to Line In of the unit S...

Page 4: ...er ra at ti io on n This mode is used when the entry device needs to dial to connect to the secure phone Going off hook with the entry device starts a 5 second timer that is restarted by any touch tone until it has timed out After 5 seconds without any touch tones the next touch tone will cause the unit to disconnect the entry device and listen for the relay activation code from the line in side S...

Reviews: