ACTIVATE
CONTROLS
FAST
COOL
ACTIVATE
CONTROLS
MAX
REF
Operation
©2012 Viking Preferred Service
7
Max Ref is enabled by pressing
and releasing the "ACTIVATE
CONTROLS" pad and then
Pressing and releasing the "MAX
FRZ" tab.
This causes the control to
temporarily (factory setting is 4 hours) change
the current refrigerator set point to 33
o
F.
Fast Cool is enabled by pressing
and releasing the "ACTIVATE
CONTROLS" pad and then
pressing and releasing the "FAST
COOL"pad.
This causes the control to
temporarily (predetermined time, factory
default is 2 hours) replace the refrigerator
setpoint to Max Ref temperature (factory
default 33
o
F).
Max Ref time duration is adjustable in
Program Mode B, range is 1 to 20 hours in 1
hour increments.
The only temperature speed used during this
mode of operation is high speed (115HZ).
Fast Cool
When "FAST COOL" is selected by pressing
the pad, "FAST COOL" is illuminated on the
display as shown in illustration above. The
down arrow will flash 1 sec on and 1 sec off
until cabinet temperature reaches set point
temperature.
Fast Cool will terminate after the time
duration has expired or if another mode is
selected or if temperature is increased or
decreased by pressing "HIGHER or LOWER"
tabs. Fast Cool can be cancelled by pressing
"FAST COOL" again, the Fast Cool will
extinguish on the display.
MAX REF
This set point temperature is not adjustable
and is programmed from factory.
The time duration is adjustable in Program
Mode B, range is 1 to 20 hours in 1 hour
increments.
When MAX REF is selected, the display
illuminates "MAX REF" as shown above. The
temperature display will move towards that
set point temperature (33
o
F) as the unit pulls
down. The down arrow will flash 1 sec on and
one sec off until cabinet temperature reaches
set point temperature.
Max Ref will terminate at the conclusion of the
time duration or if another mode is selected,
or if the temperature is manually changed by
pressing "HIGHER or LOWER" tabs. Max Ref
can also be terminated by again pressing and
releasing "MAX REF".
The conclusion or termination of this mode is
confirmed by "MAX REF" extinguishing from
display
Summary of Contents for Quiet Cool VCRB5301
Page 40: ...Schematic 40 2012 Viking Preferred Service 30 All Refrigerator Schematic Upper Section ...
Page 41: ...Schematic 2012 Viking Preferred Service 41 30 All Refrigerator Schematic Lower Section ...
Page 42: ...Schematic 42 2012 Viking Preferred Service 36 All Refrigerator Schematic Upper Section ...
Page 43: ...Schematic 2012 Viking Preferred Service 43 36 All Refrigerator Schematic Lower Section ...
Page 44: ...Wiring Diagrams 44 2012 Viking Preferred Service Wiring 30 All Refrigerator Page 1 ...
Page 45: ...Wiring Diagrams 2012 Viking Preferred Service 45 Wiring 30 All Refrigerator Page 2 ...
Page 46: ...Wiring Diagrams 46 2012 Viking Preferred Service Wiring 36 All Refrigerator Page 1 ...