To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
Disassembly
©2012 Viking Preferred Service
23
3. Remove rear, left and right side meat
saver ducts and disconnect wiring. Lower
fan is now accessible.
Fan measures approximately 3.2 Ω.
4. Reverse procedure to reinstall.
Float Switch
The unit uses a float switch to activate the
pan heater which in turn dissipates water
from the defrost cycle. When the switch is in
the down position, the switch reads open and
when the switch is in the up position it reads
continuity.
To access the float switch, remove the lower
access panel and the switch is accessible
on the left hand side. Loosen the securing
nut, disconnect wiring, and repair/replace as
necessary.
Drain Pan Heater
The unit uses a drain pan heater to vaporize
condensate created by the refrigerator
cooling process. The pan heater is energized
once the float switch closes supplying
120VAC.
To access the drain pan heater, remove
the lower access panel and the drain pan
heater is accessible. Verify the resistance is
approximately 790 Ω. Verify 120VAC to the
heater and the float switch is closed. If the
switch is closed and no voltage is supplied,
verify wiring, power disconnect switch has
not been turned “ON”, and supply voltage. If
voltage is supplied, the float switch is closed,
and the heater does not energize, replace
the heater.
Summary of Contents for Quiet Cool VCRB5301
Page 40: ...Schematic 40 2012 Viking Preferred Service 30 All Refrigerator Schematic Upper Section ...
Page 41: ...Schematic 2012 Viking Preferred Service 41 30 All Refrigerator Schematic Lower Section ...
Page 42: ...Schematic 42 2012 Viking Preferred Service 36 All Refrigerator Schematic Upper Section ...
Page 43: ...Schematic 2012 Viking Preferred Service 43 36 All Refrigerator Schematic Lower Section ...
Page 44: ...Wiring Diagrams 44 2012 Viking Preferred Service Wiring 30 All Refrigerator Page 1 ...
Page 45: ...Wiring Diagrams 2012 Viking Preferred Service 45 Wiring 30 All Refrigerator Page 2 ...
Page 46: ...Wiring Diagrams 46 2012 Viking Preferred Service Wiring 36 All Refrigerator Page 1 ...
Page 47: ...Wiring Diagrams 2012 Viking Preferred Service 47 Wiring 36 All Refrigerator Page 2 ...