background image

Summary of Contents for NGIQ532T

Page 1: ...Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA ...

Page 2: ...rol in the on position and this must be clone by a qualified technician The LP supply cylinder to be used must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CSA B337 Cy inders Spheres and Tubes for the Transportation of Dangerous Goods Gas Manifold Pressure Natural gas 4 0 W C ...

Page 3: ... BTU Nat 10 500 BTU LP 3 7 kW Nat 3 1 kW LP 15 000 BTU Nat 13 500 BTU LP 4 4 kW Nat 4 0 kW LP 1 15 000 Nat 13 500 BTU LP 4 4 kW Nat 4 0 kW LP 325 Ibs 380 Ibs 147 kg 172 kg 325 Ibs 147kg 350 Ibs 159kg Description Cutout Width Cutout Depth Cutout Height Overall Width Overall Depth Gas Requirements Electrical Requirements Grill Burner Rating TruSearTM Burner Rating If applicable Smoker Burner Rating ...

Page 4: ... LP N A 12 500 BTU Nat 10 500 BTU LP 3 7 kW Nat 3 1 kW LP 15 000 BTU Nat 13 500 BTU LP 4 4 kW Nat 4 0 kW LP 1 15 000 Nat 13 500 BTU LP 4 4 kW Nat 4 0 kW LP 325 Ibs 325 Ibs 380 Ibs 350 Ibs 147 kg 147 kg 172 kg 159 kg N A Description Cutout Width Cutout Depth Cutout Height Overall Width Overall Depth Gas Requirements Electrical Recluirements Maximum Amp Usage Grill Burner Rating TruSeaFMBurner Ratin...

Page 5: ...h the National Fuel Gas Code ANSI Z223 1 The gas grill and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 kPa The gas grill must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of that system at test p...

Page 6: ...e 7 8 2 2 cm male flare adapter on the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Attach the regulator assembly to the grill unit by pulling back the female coupler sleeve towards the regulator Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward securing the connection...

Page 7: ...tor assembly to the incoming flexible gas line attach with a 3 8 female flare adapter to the 3 8 male flare adapter to the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Attach the regulator assembly to the grill unit with the 3 8 female flare adapter on the regulator assembly to the 3 8 male flare adapter on the...

Page 8: ... an approved type and be resistive to the actions of LP Propane gas 3 8 flare j_ _ _ 3 8 flare coupling adapter LP PROPANE TANK REQUIREMENTS A dented or rusty LP Propane tank may be hazardous and should be checked by your tank supplier Never use a cylinder with a damaged valve All tanks should be equipped with an OPD overfilling protection Type 1 QCC 1 connector Tank must be mounted in vertical po...

Page 9: ...valve knob counter clockwise one turn to open 6 Blowing bubbles in the soap solution indicates that a leak is present 7 Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufacturer Do not attempt to repair the cylinder valve if it should become damaged The cylinder must be replaced 8 If you are unable to stop a leak shut off the ...

Page 10: ...combustible and or non combustible construction below the cookin 9 surface 3 When determinin 9 a suitable location for the grill take into account concerns such as exposure to wind proximity to traffic paths and keepin 9 gas supply lines as short as possible Locate the grill only in a well ventilated area Never locate the grill in a buildin 9 garag e breezeway shed or other such enclosed areas Dur...

Page 11: ...VGIQ300E VGBQ410T VGIQ410T 41 3 16 104 6 cm VGBQ410E VGIQ410E VGBQ412T 41 3 16 104 6 cm VGBQ412E VGBQ530T VGIQ530T 53 3 16 135 1 cm VGBQ530E VGIQ530E VGBQ532T VGIQ532T 53 3 16 135 1 cm VGBQ532TNGIQ532T _ 8 20 3 cm 5 3 8 13 7 cm Minimum clearance needed for removal and replacement of Rotisserie Motor 11 ...

Page 12: ...cated anywhere within 5 12 7 cm shaded area 28 71 1 cm Electrical Connection for Rotisserie Motor position unit sothat the plug is always accessible 36 91 4 cm power supply cord to be located on rear wall with a maximum distance of 2 61 0 cm beneath solid bottom support I 12 7 cm J s Access Door Opening AccessDoors sold separately refer to access door installation instructions or correct dimension...

Page 13: ...e the valve panel To accessthe air shutter on the side burners remove the grates burner bowls and grate support With a screw driver loosen the lock screw on the face of the air shutter Light the burner and adjust according to the directions below 1 If the flame is yellow turn the air shutter counter clockwise to allow more air to the burner 2 If the flame is noisy and lifting away from the burner ...

Page 14: ...IDE BURNERS If applicable O o _ I 1_ Air Shutters Orifice Fig 4 FLAME HEIGHT SIDE BURNERS If applicable 3 8 95 cm Fig 6 FLAME HEIGHT TruSear BURN ER 1 4 64 cm Fig 5 FLAME HEIGHT INFRARED BURNER 1 4 64 cm _ 14 ...

Page 15: ...blue flame no yellow tipping Check for gas leaks odors at all gas connections Each burner lights satisfactory individually or with adjacent burners lit Any adjustments necessary that are the result of the installer not following instructions will be responsibility of the installer dealer or the end user of the product REPLACEMENT PARTS Only authorized replacement parts may be used in performing se...

Page 16: ...F20054H PSO606VR ...

Reviews: