The 

LDB-2

Ring/Loop Detector monitors an

analog phone line for ringing or an in-use
condition. A built-in relay can be activated when
either of these conditions are detected.  This is
ideal for monitoring line status or for providing a
visual indication of such. 

When monitoring for ring, an internal pot can be
adjusted to allow the relay closure to stay on
steady, or follow standard ring cadence. 

The 

LDB-2

comes complete with a 12 VDC power

adapter, and can also provide 12V DC power
through its auxiliary 12V DC output terminals.

PRODUCT MANUAL

Designed, Manufactured and Supported in the USA

S E C U R I T Y   &   C O M M U N I C A T I O N   S O L U T I O N S

Provide a Contact Closure

on Ringing or Off-Hook

Features

LDB-2

Ring / Loop

Detector

August 10, 2016

Applications

Specifications

www.vikingelectronics.com

Information: (715) 386-8861

VIKING

•  Detects ring voltage and loop connect

•  Screw terminal connections

•  Wall mountable with foam tape (included) or

screws (not included)

•  Auxiliary 12V DC output

•  Adjustable time-out for relay closure

•  Two sets of relay contacts provided

•  Selectable NO (normally open) or NC

(normally closed) relay contacts

•  Limited two year warranty

•  Control a strobe light for ring indication

•  Provide relay closures on ring and off-hook

•  Trigger a security camera

•  Trigger a tape recorder

•  Phone “In Use” indicator

Power:  

120V AC to 12V DC adapter provided

Dimensions:  

2.9” x 2.1” x 1.0” (74mm x 53mm x

25mm)

Shipping Weight:  

0.86 lbs (0.4 kg)

Environmental:  

-15° F to 130° F(-26° C to 54°

C) with 5% to 95% non-condensing humidity

Contact Rating: 

.5A @ 125V AC/1A @ 30V DC

Maximum Current Draw Auxiliary 12V DC
Output:  

350mA

Minimum Loop Current:  

15 mA

Minimum Ring Voltage: 

40Vrms

Ringer Equivalence:

0.5 A REN

Connections: 

10 pin screw terminal block

Summary of Contents for LDB-2

Page 1: ... Specifications www vikingelectronics com Information 715 386 8861 VIKING Detects ring voltage and loop connect Screw terminal connections Wall mountable with foam tape included or screws not included Auxiliary 12V DC output Adjustable time out for relay closure Two sets of relay contacts provided Selectable NO normally open or NC normally closed relay contacts Limited two year warranty Control a ...

Page 2: ...e the screw heads are fully driven into the base to avoid shorting the circuit board leads Step 1 Unsnap the plastic cover see Diagram A and remove the top screw holding the circuit board Step 2 Loosen the bottom screw and rotate the circuit board to the left exposing the two mounting holes in the base see Diagram B Step 3 EScrew the base to the wall etc using 2 6 flathead or sheetrock screws Inst...

Page 3: ...e balance of the set time Additionally the LDB 2 will detect an off hook condition If the device goes off hook at any time either with or without ringing the relay will activate and remain activated for the duration of the off hook condition Operation Programming JP1 JP2 1 2 3 4 5 6 7 8 9 10 Relay Closure Time Out JP2 N O N C or JP1 N O N C or Internal View of the LDB 2 The time out POT see diagra...

Page 4: ...to Friday 8 00am 5 00pm central time So that we can give you better service before you call please 1 Know the model number the serial number and what software version you have see serial label 2 Have your Product Manual in front of you 3 It is best if you are on site RETURNING PRODUCT FOR REPAIR The following procedure is for equipment that needs repair 1 Customer must contact Viking s Technical S...

Reviews: