USE/INSTALLATION 

INSTRUCTIONS

24” W. UNDERCOUNTER/FREESTANDING WINE CELLAR

Retain for Future Reference

VIKING RANGE CORPORATION

111 FRONT STREET

GREENWOOD, MISSISSIPPI 38930 USA

(662) 455-1200

IMPORTANT - PLEASE READ AND FOLLOW

••    Before beginning, please read these instructions completely and carefully.

•  Do not remove permanently affixed labels, warnings, or plates from the product.  This may void the warranty.

•  Please observe all local and national codes and ordinances.

•  Please ensure that this product is properly grounded.
•  The installer should leave these instructions with the consumer who should retain for local inspector’s use and for

future reference.

WARNING

::

T

To

o  rre

ed

du

ucce

e  tth

he

e  rriisskk  o

off  ffiirre

e,,  e

elle

eccttrriiccaall  ssh

ho

occkk,,  o

orr  iin

njju

urryy  w

wh

he

en

n  u

ussiin

ng

g  yyo

ou

urr  w

wiin

ne

e  cce

ellllaarr,,  ffo

ollllo

ow

w  b

baassiicc  p

prre

eccaau

uttiio

on

nss  iin

nccllu

ud

diin

ng

g  tth

he

e

ffo

ollllo

ow

wiin

ng

g::

•FOR YOUR SAFETY•

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR
ANY OTHER APPLIANCE.  THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION.

IItt  iiss  yyo

ou

urr  rre

essp

po

on

nssiib

biilliittyy  tto

o  b

be

e  ssu

urre

e  yyo

ou

urr  w

wiin

ne

e  cce

ellllaarr  iiss::

•located so the front is not blocked to restrict incoming or discharge air flow.
•properly leveled.
•located in a well ventilated area. 
•connected to the proper kind of outlet, with the correct electric supply and grounding.  A 115 volt, 60 Hz, 15 amp

fused electrical supply is required.  N

NO

OT

TE

E:: Time delay fuse or circuit breaker is recommended.

•not used by anyone unable to operate it properly.
•used only for its intended purpose.
•properly maintained.

•SAVE THESE INSTRUCTIONS•

41009332

Rev. B

DANGER

SUFFOCATION HAZARD

Remove doors from your old
refrigeration unit.
Failure to do so can result in
child entrapment, which can
cause death or brain damage.

IMPORTANT:

Child entrapment and suffocation are not problems of the

past.  Junked or abandoned refrigeration products are still dangerous,
even if they will sit for “just a few days.”  If you are getting rid of your
refrigeration product, please follow the instructions below to help prevent
accidents.

BEFORE YOU THROW AWAY YOUR OLD REFRIGERATION UNIT:

•Take off the doors.
•Leave the shelves in place so that children may not easily climb inside.

PROPER DISPOSAL OF YOUR OLD REFRIGERATION UNIT

Summary of Contents for 24"

Page 1: ...PLIANCE THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION I It t i is s y yo ou ur r r re es sp po on ns si ib bi il li it ty y t to o b be e s su ur re e y yo ou ur r w wi in ne e c ce el ll la ar r i is s located so the front is not blocked to restrict incoming or discharge air flow properly leveled located in a well ventilated area connected to the proper kind of outlet with the correct electric ...

Page 2: ...bstructed for air circulation and proper operation Installation should be such that the cabinet can be moved for servicing if necessary 2 Unit should be in a well ventilated area with temperature above 550 F 130 C and below 1100 F 430 C Best results are obtained at temperatures between 650 F 180 C and 800 F 270 C for built in models and 650 F 180 C and 900 F 320 C for freestanding models 3 Provisi...

Page 3: ... El le ec ct tr ri ic c D Da at ta a 115 VAC 60 Hz Maximum amps 3 3 Approximate Shipping Weight 140 lbs 63 2 kg Min 34 1 4 87 0 cm Max 35 88 9 cm with leveling legs fully extended 30 3 4 78 1 cm 23 7 8 60 6 cm 47 1 4 120 0 cm 22 55 9 cm 24 3 8 61 9 cm 26 7 8 68 3 cm ...

Page 4: ... 3 Approximate shipping weight 140 lbs 63 2 kg Front View 30 3 4 78 1 cm Mín 34 1 4 87 0 cm Max 35 88 9 cm with leveling legs fully extended 23 7 8 60 6 cm Side View DUWC 22 55 9 cm 24 3 8 61 9 cm 25 3 8 64 5 cm 47 1 4 120 0 cm Side View DFUW 22 55 9 cm 24 3 16 61 4 cm 47 1 4 120 0 cm to front of locally supplied custom panel ...

Page 5: ...or with the 10 32 machine screws and a 1 8 allen head driver as shown in Figure 1 below 2 Press in the shoulder bushings to the top and bottom door hinge brackets Make certain that the shoulder is to the outside of the door as shown in Figure 1 below 3 Test fit the door to the unit to make certain door will hang correctly The door is hung correctly when the top of the door is parallel to the top o...

Page 6: ...Preparing the Wood Frame DFUW Model F FO OR R A A 3 3 1 1 2 2 T TO OE E K KI IC CK K C CO OV VE ER RS S T TH HE E E EN NT TI IR RE E D DO OO OR R E EX XT TR RU US SI IO ON N L LE EF FT T H HI IN NG GE E 7 13 16 19 8 cm ...

Page 7: ... IO ON NA AL L F FO OR R 4 4 T TO OE E K KI IC CK K T TO O M MA AT TC CH H E EX XI IS ST TI IN NG G C CA AB BI IN NE ET TR RY Y T TO OE E K KI IC CK K H HE EI IG GH HT T L LE EF FT T H HI IN NG GE E 7 13 16 19 8 cm ...

Page 8: ...8 F FO OR R A A 3 3 1 1 2 2 T TO OE E K KI IC CK K C CO OV VE ER RS S T TH HE E E EN NT TI IR RE E D DO OO OR R E EX XT TR RU US SI IO ON N R RI IG GH HT T H HI IN NG GE E 7 13 16 19 8 cm ...

Page 9: ...unterbore holes from back side of panel for handle screw heads to be flush O OP PT TI IO ON NA AL L F FO OR R 4 4 T TO OE E K KI IC CK K T TO O M MA AT TC CH H E EX XI IS ST TI IN NG G C CA AB BI IN NE ET TR RY Y T TO OE E K KI IC CK K H HE EI IG GH HT T R RI IG GH HT T H HI IN NG GE E 1 23 32 4 4 cm min width to cover door extrusion 7 13 16 19 8 cm ...

Page 10: ...re lock operates properly 8 Install the door to the unit Use the supplied plastic washer as shown in the figure below 9 Realigning the door may be necessary Any final door adjustments can be made using a 1 8 allen head driver to adjust the door s hinges See figure below 10 Attach the door light striker plate as shown using the 5 16 hex or phillips head screws provided Make certain the light is abl...

Page 11: ...ed in until snug 3 Repeat steps 1 2 with the exception of tipping the unit forwards to screw in the back two leg levelers 4 The leg levelers are not installed 5 The unit should be level from front to back and side to side If floor conditions do not allow the unit to sit level adjust the leg levelers by turning the required leg leveler counter clockwise to increase the height and clockwise to reduc...

Page 12: ...ble local codes and ordinances The third ground plug SHOULD NOT under any circumstances be cut or removed All UL listed refrigerated products are equipped with this type of plug Power Supply with 3 prong grounding plug Grounding type wall receptacle FINAL PREPARATION 1 Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior of the wine cellar should be w...

Page 13: ...ght remains on continuously LIGHT TUBE REPLACEMENT N No ot te e Please contact your Viking Range Corporation parts distributor or dealer to order new light tubes Use only approved replacement light tubes from your dealer or manufacturer DANGER Failure to disconnect the power cord when changing the light tube may result in electrical shock This product uses two 6 watt light tubes to illuminate the ...

Page 14: ...wders On full overlay models use caution when cleaning near logo area P Pa ai in nt te ed d S Su ur rf fa ac ce es s Wash with warm soapy water D DO O N NO OT T U US SE E steel wool abrasive cleansers ammonia acids or commercial oven cleaners which may damage the finish D Do oo or r G Ga as sk ke et t The vinyl gasket may be cleaned with mild soap and water a baking soda and water solution or a mi...

Page 15: ...dily available Model number Serial number Date of purchase Name of dealer from whom purchased If you are unable to obtain the name of an authorized service agency or if you continue to have service problems contact Viking Range Corporation at 888 845 4641 or write to V VI IK KI IN NG G P PR RE EF FE ER RR RE ED D S SE ER RV VI IC CE E 1 11 11 1 F Fr ro on nt t S St tr re ee et t G Gr re ee en nw w...

Page 16: ...alteration improper installation improper operation or repair or service to the product by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental damage whethe...