background image

Summary of Contents for VEWD173

Page 1: ...Viking Installation Guide US ii ii n _ w I I o VIKTNG Built in Electric Warming Drawers Indoor and Outdoor Models Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA ...

Page 2: ...cturer s warranty Make sure that incoming voltage is the same as unit rating An electric rating plate specifying voltage hertz wattage amps and phase is attached to the product Wiring the warming drawer with more voltage than it is rated for may cause severe damage to the thermostat element and other components Wiring the warming drawer with less voltage than it is rated for may cause significant ...

Page 3: ...DEWD171 DEWD101 A 25 1 4 28 1 4 34 64 1 cm 71 8 cm 86 4 cm Mounting Screws 4 8 x 3 4 Cavity Assy Drawer Assy OUTDOOR MODELS Cabinet 5 1 cm min 23 3 8 Model A 91 4 23 5 cm Cavity Assy I all around opening silicon caulk that is provided VEWD173T 25 1 4 64 1 cm VEWD103T 28 1 4 71 8 cm VEWD163T 34 86 4 cm Dra Assy ...

Page 4: ...ont with the 6 six 8 x 3 4 screws provided CABINET INSTALLATION To remove drawer assembly pull warming drawer pan out until fully extended Slide finger along the right and left side until you reach the black hand latches located at the front of the rails Pull up on both the right and left latches and pull drawer pan support completely out For outdoor models ONLY Apply silicon caulk that is provide...

Page 5: ...trical opening When facing cabinet opening is located on right side 8 31 32 22 8 cm MODEL VEWD172 DFWD171 VEWD102 DFWD101 VEWD162 VEWD172T VEWD102T VEWD162T DEWD171 DEWD101 B 26 1 2 26 29 1 2 29 35 1 4 67 3 cm 66 0 cm 74 9 cm 73 7 cm 89 5 cm C 24 7 8 24 7 8 27 7 8 27 7 8 33 5 8 63 2 cm 63 2 cm 70 8 cm 70 8 cm 85 4 cm 5 ...

Page 6: ...SIDE VEWD 26 3 4 67 9 cm 23 1 4 59 1 cm 1 3 8 3 5 cm _ 25 3 4 65 4 cm SIDE DEWD 26 3 4 67 9 cm 23 1 4 59 1 cm _1 3 8 3 5 cm 26 1 4 66 7 cm SIDE DFWD 23 1 4 58 7 cm 23 1 4 58 7 cm _ J h i ...

Page 7: ...E 15 WHITE 10 GREEN YELLOW B FOR CONNECTION TO THE FACTORY INSTALLED TERMINAL BLOCK USE ALUMINUM OR COPPER CONDUCTORS WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK AND FIRE DO NOT USE A FLEXIBLE POWER SUPPLY CORD WITH THIS APPLIANCE TERMINAL BLOCK PE070147 THERMOSTAT PB10167 NEUTRAL POWER SUPPLY CONNECTIONS ER O _UTOOOR INSTALLER MUST SUPPLY GFC INTERRUPT ...

Page 8: ...ii_ o V_kmg Range Corporation 111 Front Street Greenwood M_sslssFppr38930 USA 662 455 1200 For more product mformat_on call 1 888 VIKING1 845 4641 or ws_t the V_k_ngweb stte www wkmgrange com F1615L PSO206VR ...

Reviews: