1
PACKING LIST / TOOLS NEEDED
PANEL DIMENSIONS
FITTINGS / TECHNICAL DATA
WALL/CORNER INSTALLATION
CARE AND TROUBLE SHOOTING
WARRANTY
MODEL VG08003
CONTENT
Page 1: ...1 PACKING LIST TOOLS NEEDED PANEL DIMENSIONS FITTINGS TECHNICAL DATA WALL CORNER INSTALLATION CARE AND TROUBLE SHOOTING WARRANTY MODEL VG08003 CONTENT ...
Page 2: ...GAUGE TO ASSURE PROPER PRESSURE MAX 60 PSI RECOMMENDED SHUT OFF VALVES FOR HOT AND COLD DESCRIPTION MODEL NUMBER PANEL HOUSING 88058 HEAD SHOWER 88024 HAND SHOWER HOSE 88004 HAND SHOWER 84004 FLEXIBLE HOSES 16 LONG WITH 1 2 FEMALE 88005 CONNECTION FOR HOT COLD WATER SUPPLY FIXING PLUGS 6PC 84000 WALL MOUNTING BRACKET 3PC 88006 CORNER MOUNTING BRACKET 88007A CORNER MOUNTING BRACKET 88007B BLUE WASH...
Page 3: ...PANEL DIMENSIONS 6 3 4 13 13 10 1 4 6 3 4 8 3 THE MEASUREMENTS IN INCHES ARE ROUNDED TO THE NEAREST 1 8 NOTE Dimension may vary up to 1 4 It is highly recommended to pull all dimensions off actual model for installation and measuring purposes ...
Page 4: ...8004 HAND SHOWER 84004 FLEXIBLE HOSES CONNECT TO COLD HOT WATER 88005 DIVERTER 88028 88031 OVERHEAD SHOWER 88024 STAINLESS STEEL 88058 40 1 8 21 3 4 WATER HOSE CONNECTION MOUNTING BRACKET 4 THERMOSTATIC CONTROL 88030 88032 SCALD GUARD LOCATED UNDER HANDLE TECHNICAL DATA MIN FLOW PRESSURE 30 PSI MAX OPERATING PRESSURE 60 PSI OVERALL WATER PRESSURE IS 2 5 GALLONS PER MINUTE AT 60 PSI MOUNTING BRACKE...
Page 5: ...MODEL VG08003 5 88074 88006 ...
Page 6: ...the hoses have been connected to the incorrect supplies Please disconnect the hoses reattach them to the correct supplies and test the unit before calling the Vigo Technical Service center Note to customer It may be advantageous to bend brackets towards person for easier installation Make sure not to over bend and cause damage to the brackets ...
Page 7: ...MODEL VG08003 7 Place the larger of the two corner brackets on the top portion of the wall and the smaller of the two brackets near the bottom of the wall 88074 88007A 88006 88074 88007B 88007B ...
Page 8: ...MODEL VG08003 8 X 2 PANEL 88008 84000 84005 84004 88024 84001 84044 ...
Page 9: ... necessary Regular cleaning can prevent calcification When using spray cleaner spray first onto a cloth or sponge never directly spray onto the sanitary tapware as drops could enter openings and gaps and cause damage After cleaning rinse thoroughly with clean water to remove any cleaner residue Important Residues of liquid soaps shampoos and shower foams can also cause damage so rinse with clean w...
Page 10: ...ser This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation pertaining to such installations This warranty does not apply unless the VIGO Product is installed by fully insured licensed professionals Vigo strongly recommends that such licensed professionals have experience...