background image

PoE Maximum Load Meter w/ Voltage & Power Monitor User Manual

 

Application Drawing 

Important Safety Warning

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

The Vi00024 Setup

The Smart Choice for Transmission Solutions                       

www.vigitron.com

- Read these instructions.

- Keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Use in accordance with the manufacturer’s instructions.

- To reduce the risk of fire or electrical shock, do not expose these products 

  to rain, moisture, dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron

  equipment.

- DO NOT install the unit in a place where the operating ambient tempera

  ture exceeds 75°C.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long 

  periods of time.

- Refer all servicing to qualified service personnel. Servicing is required

  when the apparatus has been damaged in any way, such as a power 

  supply cord or plug is damaged, liquid has been spilled, or objects have

  fallen into the apparatus, the apparatus has been exposed to rain or 

  moisture, does not operate normally, or has been dropped.

- The network cable is used as the disconnect device and shall remain

  readily operable.

Vi00024_UM

Vigitron’s patent pending Vi00024 is an innovative test tool that installation 

reliability by measuring PoE capacity at any point of a networks before 

installing a camera. The Vi00024 simulates PoE devices and measures the 

maximum PoE capacity received from the PoE source over the network. It is 

compliant with IEEE 802.3af/at/bt standard up to 74W. 
The Vi00024 operates in both Manual and Auto mode. In manual mode the 

user can manually increase the PoE consumption of the Vi00024 until it 

reaches the maximum available PoE.  In the auto mode, the Vi00024 with 

the push one bottom can measure maximum available PoE in a few 

seconds.
The Vi00024 includes a rechargeable battery that can be charged via a 

USB type C connector using any standard USB charger. It is very low power 

and with a full charge can operate for several days. 
The Vi00024’s compact and light weight construction makes is easy to carry 

and use.  It is easy to use and helps to speed up installations and prevent 

service calls by locating and helping to solve PoE problems. 

The Vi00024 can measure Maximum available PoE up to 74W over standard networks.  

The Vi00024 can measure Maximum available PoE up to 74W over Extended UTP networks.

Cat 5/6

PoE

328 ft. (100m)

PoE

328 ft. (100m)

PoE

328 ft. (100m)

Vi30208

56VDC

Vi10240

Measuring Maximum PoE over an Extended UTP network

Measuring Maximum PoE over a standard network

PoE Switch

Vi00024

Vi2301A

Vi2301A

Vi00024

PoE

Extended UTP

Power

 

Mate

TM

Turning On

• Hold down the Button to Turn ON the Vi00024 and view “

Selection 

Menu” 

on the display .

• In 

Selection Menu:

      • Press Once for 

AUTO Mode

.

    

• Press Twice for 

Manual Mode

Auto Mode

After selecting Auto Mode the Vi00024 will turn on a PoE Load and 

increase the load gradually until the PoE source shuts down due to 

exceeding its maximum load capacity. Then the Vi00024 will display the 

maximum PoE level.

      • Press Twice to exit the 

Auto Mode

.

Manual Mode

In the 

Manual Mode

  select the load increase mode:

      • Press Once for 

Class Mode

      • Press Twice for 

5W Mode

   Class Mode

     In this mode select the desired PoE Class. 

     • Press Twice to exit Manual/Class Mode.

   5W Mode

     In This mode Press Once each time to increase the PoE load by 5W up

     to 74W.

      • If time out, Press Once to resume operation.

      • Press Twice to exit Manual/5W Mode.

Turning Off

• Hold down the Button for 3 Second to turn off the Vi00024.

• If the Vi00024 is left idle for 1 minute, it will shut down

unit time out